- Catalogue
- Condensers
- KA/KB (General)
KA/KB (General)
- Refrigerants
- R134a, R22, R290, R32, R404A, R407A, R407B, R407C, R407F, R410A, R448A, R449A, R450a, R452a, R454A, R454C, R455A, R507A, R513a
- Capacity
- 14.80–1425.75 kW
- Fans
- ⌀500, ⌀630, ⌀800, ⌀910 mm
- Max. working pressure
- 27 bar
Model nomenclature
How to read the model codes of this series, with an example.
-
A
Series KA/KB = KA = vertical, KB = horizontal industrial condenser.
-
B
Fin type (optional "t") — = absent: standard corrugated finst = t: louvered fins (high-efficiency fin surface)
-
C
Fan rows (optional "Nx") — Catalogue: "Fan Row no." (number before x/X). — = absent: 1 fan row2x = 2 fan rows
-
D
Number of fans per row — Digit 1-9; total fans = fan rows x this digit.
-
E
Fan diameter — Two digits = diameter / 10 (91 = Ø910). 50 = Ø500 mm63 = Ø630 mm80 = Ø800 mm91 = Ø910 mm
-
G
Coil tube rows (2nd dimensional letter) A = 2 tube rowsB = 3 tube rowsC = 4 tube rowsD = 5 tube rows
-
H
Fin spacing — Catalogue fin-spacing code. 1 = 2.1 mm5 = 2.5 mm
-
I
Generation code — Catalogue: "Generation Code". B = generation B
-
J
Fan data (fan motor code) — Catalogue: "Fan Data". Two digits select the fan motor (supply, poles); the meaning is series-specific. 01 = fan motor code; supply/poles vary with diameter03 = three-phase 400 V 50 Hz, 12-pole AC fan (in this series)04 = fan motor code; supply/poles vary with diameter06 = three-phase 400 V 50 Hz, 6-pole AC fan (in this series)08 = three-phase 400 V 50 Hz, 4-pole AC fan (in this series)09 = single-phase 230 V 50 Hz, 4-pole AC fan (in this series)10 = three-phase 400 V 50 Hz, 4-pole AC fan (in this series)19 = three-phase 400 V 50 Hz, 4-pole AC fan (in this series)
| Model | Heat rejection [kW] i Nominal conditions (EN 327): air inlet 25 °C, condensing temperature 40 °C (ΔT 15 K), gas inlet superheat 26 K, no subcooling, relative humidity 50 % | Fans | Air flow [m³/h] | Variants |
|---|---|---|---|---|
| KA/KB-180FD1-B01I C | 80.08 kW | 1 × ⌀800 | 17,817 |
Variants (1) |
| KA/KB-350CD5-B01I C | 80.45 kW | 3 × ⌀500 | 20,340 |
Variants (1) |
| KA/KB-t-2x163HA5-B19 C | 80.49 kW | 2 × ⌀630 | 26,028 |
Variants (1) |
| KA/KB-t-2x180EA1-B01I C | 80.50 kW | 2 × ⌀800 | 34,693 |
Variants (1) |
| KA/KB-2x163GB1-B01 C | 80.53 kW | 2 × ⌀630 | 19,834 |
Variants (1) |
| KA/KB-t-450EB1-B04 C | 80.60 kW | 4 × ⌀500 | 19,251 |
Variants (1) |
| KA/KB-191BC1-B04 C | 80.60 kW | 1 × ⌀910 | 23,980 |
Variants (1) |
| KA/KB-191HB5-B04I C | 80.67 kW | 1 × ⌀910 | 31,141 |
Variants (1) |
| KA/KB-363BB5-B01 C | 80.68 kW | 3 × ⌀630 | 26,948 |
Variants (1) |
| KA/KB-191HB5-B04 C | 80.71 kW | 1 × ⌀910 | 31,163 |
Variants (1) |
| KA/KB-t-450EA1-B09 C | 80.71 kW | 4 × ⌀500 | 29,049 |
Variants (1) |
| KA/KB-2x250CC1-B04 C | 80.72 kW | 4 × ⌀500 | 18,866 |
Variants (1) |
| KA/KB-t-2x163EB5-B08 C | 80.74 kW | 2 × ⌀630 | 29,207 |
Variants (1) |
| KA/KB-2x163AC5-B19 C | 80.79 kW | 2 × ⌀630 | 23,067 |
Variants (1) |
| KA/KB-t-2x180HA1-B03 C | 80.80 kW | 2 × ⌀800 | 21,577 |
Variants (1) |
| KA/KB-191BC1-B04I C | 80.86 kW | 1 × ⌀910 | 24,098 |
Variants (1) |
| KA/KB-t-263HA5-B19 C | 80.99 kW | 2 × ⌀630 | 26,046 |
Variants (1) |
| KA/KB-2x180CB5-B01 C | 80.99 kW | 2 × ⌀800 | 36,505 |
Variants (1) |
| KA/KB-263GB1-B01 C | 81.00 kW | 2 × ⌀630 | 19,860 |
Variants (1) |
| KA/KB-t-191KC5-B04 C | 81.05 kW | 1 × ⌀910 | 23,589 |
Variants (1) |
| KA/KB-2x250CD5-B04 C | 81.12 kW | 4 × ⌀500 | 18,431 |
Variants (1) |
| KA/KB-t-180LB5-B01 C | 81.17 kW | 1 × ⌀800 | 22,646 |
Variants (1) |
| KA/KB-t-191KC5-B04I C | 81.26 kW | 1 × ⌀910 | 23,675 |
Variants (1) |
| KA/KB-t-280HA1-B03 C | 81.30 kW | 2 × ⌀800 | 21,614 |
Variants (1) |
| KA/KB-t-350EC5-B09 C | 81.32 kW | 3 × ⌀500 | 19,906 |
Variants (1) |
| KA/KB-t-2x163HB5-B01 C | 81.34 kW | 2 × ⌀630 | 19,703 |
Variants (1) |
| KA/KB-2x163AB1-B08 C | 81.39 kW | 2 × ⌀630 | 29,671 |
Variants (1) |
| KA/KB-t-2x163EB1-B19 C | 81.42 kW | 2 × ⌀630 | 23,036 |
Variants (1) |
| KA/KB-350BD5-B09 C | 81.46 kW | 3 × ⌀500 | 19,499 |
Variants (1) |
| KA/KB-450CC1-B04 C | 81.48 kW | 4 × ⌀500 | 18,985 |
Variants (1) |
| KA/KB-191GC5-B04 C | 81.54 kW | 1 × ⌀910 | 27,417 |
Variants (1) |
| KA/KB-t-263EB5-B08 C | 81.55 kW | 2 × ⌀630 | 29,341 |
Variants (1) |
| KA/KB-2x250BC1-B04 C | 81.60 kW | 4 × ⌀500 | 18,658 |
Variants (1) |
| KA/KB-t-263HB5-B01 C | 81.72 kW | 2 × ⌀630 | 19,732 |
Variants (1) |
| KA/KB-191GC5-B04I C | 81.75 kW | 1 × ⌀910 | 27,525 |
Variants (1) |
| KA/KB-450BC1-B04 C | 81.78 kW | 4 × ⌀500 | 18,658 |
Variants (1) |
| KA/KB-t-180HC1-B01I C | 81.84 kW | 1 × ⌀800 | 18,006 |
Variants (1) |
| KA/KB-280CB5-B01 C | 81.90 kW | 2 × ⌀800 | 36,756 |
Variants (1) |
| KA/KB-263AC5-B19 C | 81.95 kW | 2 × ⌀630 | 23,067 |
Variants (1) |
| KA/KB-t-180HC5-B01 C | 82.03 kW | 1 × ⌀800 | 20,137 |
Variants (1) |
| KA/KB-t-263EB1-B19 C | 82.14 kW | 2 × ⌀630 | 23,115 |
Variants (1) |
| KA/KB-450CD5-B04 C | 82.19 kW | 4 × ⌀500 | 18,555 |
Variants (1) |
| KA/KB-t-550EA5-B09 C | 82.22 kW | 5 × ⌀500 | 36,768 |
Variants (1) |
| KA/KB-t-280EA1-B01 C | 82.31 kW | 2 × ⌀800 | 37,651 |
Variants (1) |
| KA/KB-263AB1-B08 C | 82.44 kW | 2 × ⌀630 | 29,671 |
Variants (1) |
| KA/KB-180KC5-B01 C | 82.47 kW | 1 × ⌀800 | 22,480 |
Variants (1) |
| KA/KB-2x180FB5-B03 C | 82.47 kW | 2 × ⌀800 | 21,389 |
Variants (1) |
| KA/KB-2x250BB5-B09 C | 82.53 kW | 4 × ⌀500 | 28,446 |
Variants (1) |
| KA/KB-280FB5-B03 C | 82.59 kW | 2 × ⌀800 | 21,389 |
Variants (1) |
| KA/KB-t-363EA1-B01 C | 82.63 kW | 3 × ⌀630 | 27,274 |
Variants (1) |
Nominal conditions (EN 327): air inlet 25 °C, condensing temperature 40 °C (ΔT 15 K), gas inlet superheat 26 K, no subcooling, relative humidity 50 %
Downloads
- KA/KB-180FD1-B01I C — product datasheet (PDF)
- KA/KB-350CD5-B01I C — product datasheet (PDF)
- KA/KB-t-2x163HA5-B19 C — product datasheet (PDF)
- KA/KB-t-2x180EA1-B01I C — product datasheet (PDF)
- KA/KB-2x163GB1-B01 C — product datasheet (PDF)
- KA/KB-t-450EB1-B04 C — product datasheet (PDF)
- KA/KB-191BC1-B04 C — product datasheet (PDF)
- KA/KB-191HB5-B04I C — product datasheet (PDF)
- KA/KB-363BB5-B01 C — product datasheet (PDF)
- KA/KB-191HB5-B04 C — product datasheet (PDF)
- KA/KB-t-450EA1-B09 C — product datasheet (PDF)
- KA/KB-2x250CC1-B04 C — product datasheet (PDF)
- KA/KB-t-2x163EB5-B08 C — product datasheet (PDF)
- KA/KB-2x163AC5-B19 C — product datasheet (PDF)
- KA/KB-t-2x180HA1-B03 C — product datasheet (PDF)
- KA/KB-191BC1-B04I C — product datasheet (PDF)
- KA/KB-t-263HA5-B19 C — product datasheet (PDF)
- KA/KB-2x180CB5-B01 C — product datasheet (PDF)
- KA/KB-263GB1-B01 C — product datasheet (PDF)
- KA/KB-t-191KC5-B04 C — product datasheet (PDF)
- KA/KB-2x250CD5-B04 C — product datasheet (PDF)
- KA/KB-t-180LB5-B01 C — product datasheet (PDF)
- KA/KB-t-191KC5-B04I C — product datasheet (PDF)
- KA/KB-t-280HA1-B03 C — product datasheet (PDF)
- KA/KB-t-350EC5-B09 C — product datasheet (PDF)
- KA/KB-t-2x163HB5-B01 C — product datasheet (PDF)
- KA/KB-2x163AB1-B08 C — product datasheet (PDF)
- KA/KB-t-2x163EB1-B19 C — product datasheet (PDF)
- KA/KB-350BD5-B09 C — product datasheet (PDF)
- KA/KB-450CC1-B04 C — product datasheet (PDF)
- KA/KB-191GC5-B04 C — product datasheet (PDF)
- KA/KB-t-263EB5-B08 C — product datasheet (PDF)
- KA/KB-2x250BC1-B04 C — product datasheet (PDF)
- KA/KB-t-263HB5-B01 C — product datasheet (PDF)
- KA/KB-191GC5-B04I C — product datasheet (PDF)
- KA/KB-450BC1-B04 C — product datasheet (PDF)
- KA/KB-t-180HC1-B01I C — product datasheet (PDF)
- KA/KB-280CB5-B01 C — product datasheet (PDF)
- KA/KB-263AC5-B19 C — product datasheet (PDF)
- KA/KB-t-180HC5-B01 C — product datasheet (PDF)
- KA/KB-t-263EB1-B19 C — product datasheet (PDF)
- KA/KB-450CD5-B04 C — product datasheet (PDF)
- KA/KB-t-550EA5-B09 C — product datasheet (PDF)
- KA/KB-t-280EA1-B01 C — product datasheet (PDF)
- KA/KB-263AB1-B08 C — product datasheet (PDF)
- KA/KB-180KC5-B01 C — product datasheet (PDF)
- KA/KB-2x180FB5-B03 C — product datasheet (PDF)
- KA/KB-2x250BB5-B09 C — product datasheet (PDF)
- KA/KB-280FB5-B03 C — product datasheet (PDF)
- KA/KB-t-363EA1-B01 C — product datasheet (PDF)
Ask about product
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.