How to read the model codes of this series, with an example.
-
A
Series KA/KB = KA = vertical, KB = horizontal industrial condenser.
-
B
Fin type (optional "t") — = absent: standard corrugated finst = t: louvered fins (high-efficiency fin surface)
-
C
Fan rows (optional "Nx") — Catalogue: "Fan Row no." (number before x/X). — = absent: 1 fan row2x = 2 fan rows
-
D
Number of fans per row — Digit 1-9; total fans = fan rows x this digit.
-
E
Fan diameter — Two digits = diameter / 10 (91 = Ø910). 50 = Ø500 mm63 = Ø630 mm80 = Ø800 mm91 = Ø910 mm
-
G
Coil tube rows (2nd dimensional letter) A = 2 tube rowsB = 3 tube rowsC = 4 tube rowsD = 5 tube rows
-
H
Fin spacing — Catalogue fin-spacing code. 1 = 2.1 mm5 = 2.5 mm
-
I
Generation code — Catalogue: "Generation Code". B = generation B
-
J
Fan data (fan motor code) — Catalogue: "Fan Data". Two digits select the fan motor (supply, poles); the meaning is series-specific. 01 = fan motor code; supply/poles vary with diameter03 = three-phase 400 V 50 Hz, 12-pole AC fan (in this series)04 = fan motor code; supply/poles vary with diameter06 = three-phase 400 V 50 Hz, 6-pole AC fan (in this series)08 = three-phase 400 V 50 Hz, 4-pole AC fan (in this series)09 = single-phase 230 V 50 Hz, 4-pole AC fan (in this series)10 = three-phase 400 V 50 Hz, 4-pole AC fan (in this series)19 = three-phase 400 V 50 Hz, 4-pole AC fan (in this series)
| Model | Heat rejection [kW] i Nominal conditions (EN 327): air inlet 25 °C, condensing temperature 40 °C (ΔT 15 K), gas inlet superheat 26 K, no subcooling, relative humidity 50 % | Fans | Air flow [m³/h] | Variants |
|---|---|---|---|---|
| KA/KB-2x250BC1-B09 C | 103.82 kW | 4 × ⌀500 | 26,664 |
Variants (1) |
| KA/KB-t-2x163HA1-B08 C | 103.86 kW | 2 × ⌀630 | 34,109 |
Variants (1) |
| KA/KB-363BC1-B01 C | 103.88 kW | 3 × ⌀630 | 25,195 |
Variants (1) |
| KA/KB-2x350CB1-B04 C | 103.89 kW | 6 × ⌀500 | 29,807 |
Variants (1) |
| KA/KB-2x180CC1-B01I C | 103.94 kW | 2 × ⌀800 | 30,733 |
Variants (1) |
| KA/KB-2x250CD5-B09 C | 104.18 kW | 4 × ⌀500 | 26,313 |
Variants (1) |
| KA/KB-363AC1-B06I C | 104.33 kW | 3 × ⌀630 | 24,684 |
Variants (1) |
| KA/KB-363BD5-B06I C | 104.50 kW | 3 × ⌀630 | 24,389 |
Variants (1) |
| KA/KB-450BC1-B10 C | 104.55 kW | 4 × ⌀500 | 27,407 |
Variants (1) |
| KA/KB-t-650EB5-B04 C | 104.56 kW | 6 × ⌀500 | 29,431 |
Variants (1) |
| KA/KB-2x263BB5-B06I C | 104.65 kW | 4 × ⌀630 | 35,066 |
Variants (1) |
| KA/KB-450BC1-B09 C | 104.67 kW | 4 × ⌀500 | 26,664 |
Variants (1) |
| KA/KB-t-380HA5-B03 C | 104.87 kW | 3 × ⌀800 | 32,840 |
Variants (1) |
| KA/KB-191DC5-B04I C | 104.99 kW | 1 × ⌀910 | 29,881 |
Variants (1) |
| KA/KB-2x163GC5-B19 C | 105.02 kW | 2 × ⌀630 | 25,545 |
Variants (1) |
| KA/KB-t-191MB1-B04I C | 105.04 kW | 1 × ⌀910 | 29,940 |
Variants (1) |
| KA/KB-280CC1-B01I C | 105.08 kW | 2 × ⌀800 | 30,946 |
Variants (1) |
| KA/KB-191DC5-B04 C | 105.09 kW | 1 × ⌀910 | 29,918 |
Variants (1) |
| KA/KB-2x250BC1-B10 C | 105.09 kW | 4 × ⌀500 | 27,407 |
Variants (1) |
| KA/KB-t-191MB1-B04 C | 105.15 kW | 1 × ⌀910 | 29,984 |
Variants (1) |
| KA/KB-t-380EB1-B03 C | 105.21 kW | 3 × ⌀800 | 24,668 |
Variants (1) |
| KA/KB-363AC1-B01 C | 105.25 kW | 3 × ⌀630 | 24,953 |
Variants (1) |
| KA/KB-363BD5-B01 C | 105.29 kW | 3 × ⌀630 | 24,613 |
Variants (1) |
| KA/KB-450CD5-B09 C | 105.31 kW | 4 × ⌀500 | 26,495 |
Variants (1) |
| KA/KB-463BB5-B06I C | 105.35 kW | 4 × ⌀630 | 35,166 |
Variants (1) |
| KA/KB-t-550EB5-B09 C | 105.36 kW | 5 × ⌀500 | 34,910 |
Variants (1) |
| KA/KB-2x250BC1-B01I C | 105.59 kW | 4 × ⌀500 | 27,278 |
Variants (1) |
| KA/KB-t-191LC1-B04 C | 105.61 kW | 1 × ⌀910 | 25,447 |
Variants (1) |
| KA/KB-263GC5-B19 C | 105.62 kW | 2 × ⌀630 | 25,573 |
Variants (1) |
| KA/KB-363BB5-B08 C | 105.63 kW | 3 × ⌀630 | 45,660 |
Variants (1) |
| KA/KB-t-2x280EA5-B03 C | 105.71 kW | 4 × ⌀800 | 37,830 |
Variants (1) |
| KA/KB-t-363EC5-B01 C | 105.75 kW | 3 × ⌀630 | 24,657 |
Variants (1) |
| KA/KB-2x250CD5-B10 C | 105.89 kW | 4 × ⌀500 | 27,088 |
Variants (1) |
| KA/KB-2x163BD1-B08 C | 105.94 kW | 2 × ⌀630 | 26,754 |
Variants (1) |
| KA/KB-t-191LC1-B04I C | 105.98 kW | 1 × ⌀910 | 25,564 |
Variants (1) |
| KA/KB-2x180GB5-B01I C | 105.99 kW | 2 × ⌀800 | 39,161 |
Variants (1) |
| KA/KB-2x163AD1-B08 C | 106.01 kW | 2 × ⌀630 | 26,585 |
Variants (1) |
| KA/KB-t-2x180EB1-B01 C | 106.12 kW | 2 × ⌀800 | 33,134 |
Variants (1) |
| KA/KB-2x263BB5-B01 C | 106.13 kW | 4 × ⌀630 | 35,807 |
Variants (1) |
| KA/KB-2x250CD5-B01I C | 106.13 kW | 4 × ⌀500 | 26,949 |
Variants (1) |
| KA/KB-380AB1-B03 C | 106.16 kW | 3 × ⌀800 | 27,685 |
Variants (1) |
| KA/KB-2x180AB1-B01 C | 106.23 kW | 2 × ⌀800 | 37,496 |
Variants (1) |
| KA/KB-380CC1-B03 C | 106.28 kW | 3 × ⌀800 | 24,072 |
Variants (1) |
| KA/KB-450BC1-B01I C | 106.44 kW | 4 × ⌀500 | 27,278 |
Variants (1) |
| KA/KB-263BD1-B08 C | 106.53 kW | 2 × ⌀630 | 26,898 |
Variants (1) |
| KA/KB-280GB5-B01I C | 106.71 kW | 2 × ⌀800 | 39,262 |
Variants (1) |
| KA/KB-463BB5-B01 C | 106.89 kW | 4 × ⌀630 | 35,931 |
Variants (1) |
| KA/KB-t-2x250EC5-B09 C | 106.93 kW | 4 × ⌀500 | 26,359 |
Variants (1) |
| KA/KB-450CD5-B10 C | 106.96 kW | 4 × ⌀500 | 27,254 |
Variants (1) |
| KA/KB-363AD5-B06I C | 107.00 kW | 3 × ⌀630 | 24,160 |
Variants (1) |
Nominal conditions (EN 327): air inlet 25 °C, condensing temperature 40 °C (ΔT 15 K), gas inlet superheat 26 K, no subcooling, relative humidity 50 %
Downloads
- KA/KB-2x250BC1-B09 C — product datasheet (PDF)
- KA/KB-t-2x163HA1-B08 C — product datasheet (PDF)
- KA/KB-363BC1-B01 C — product datasheet (PDF)
- KA/KB-2x350CB1-B04 C — product datasheet (PDF)
- KA/KB-2x180CC1-B01I C — product datasheet (PDF)
- KA/KB-2x250CD5-B09 C — product datasheet (PDF)
- KA/KB-363AC1-B06I C — product datasheet (PDF)
- KA/KB-363BD5-B06I C — product datasheet (PDF)
- KA/KB-450BC1-B10 C — product datasheet (PDF)
- KA/KB-t-650EB5-B04 C — product datasheet (PDF)
- KA/KB-2x263BB5-B06I C — product datasheet (PDF)
- KA/KB-450BC1-B09 C — product datasheet (PDF)
- KA/KB-t-380HA5-B03 C — product datasheet (PDF)
- KA/KB-191DC5-B04I C — product datasheet (PDF)
- KA/KB-2x163GC5-B19 C — product datasheet (PDF)
- KA/KB-t-191MB1-B04I C — product datasheet (PDF)
- KA/KB-280CC1-B01I C — product datasheet (PDF)
- KA/KB-191DC5-B04 C — product datasheet (PDF)
- KA/KB-2x250BC1-B10 C — product datasheet (PDF)
- KA/KB-t-191MB1-B04 C — product datasheet (PDF)
- KA/KB-t-380EB1-B03 C — product datasheet (PDF)
- KA/KB-363AC1-B01 C — product datasheet (PDF)
- KA/KB-363BD5-B01 C — product datasheet (PDF)
- KA/KB-450CD5-B09 C — product datasheet (PDF)
- KA/KB-463BB5-B06I C — product datasheet (PDF)
- KA/KB-t-550EB5-B09 C — product datasheet (PDF)
- KA/KB-2x250BC1-B01I C — product datasheet (PDF)
- KA/KB-t-191LC1-B04 C — product datasheet (PDF)
- KA/KB-263GC5-B19 C — product datasheet (PDF)
- KA/KB-363BB5-B08 C — product datasheet (PDF)
- KA/KB-t-2x280EA5-B03 C — product datasheet (PDF)
- KA/KB-t-363EC5-B01 C — product datasheet (PDF)
- KA/KB-2x250CD5-B10 C — product datasheet (PDF)
- KA/KB-2x163BD1-B08 C — product datasheet (PDF)
- KA/KB-t-191LC1-B04I C — product datasheet (PDF)
- KA/KB-2x180GB5-B01I C — product datasheet (PDF)
- KA/KB-2x163AD1-B08 C — product datasheet (PDF)
- KA/KB-t-2x180EB1-B01 C — product datasheet (PDF)
- KA/KB-2x263BB5-B01 C — product datasheet (PDF)
- KA/KB-2x250CD5-B01I C — product datasheet (PDF)
- KA/KB-380AB1-B03 C — product datasheet (PDF)
- KA/KB-2x180AB1-B01 C — product datasheet (PDF)
- KA/KB-380CC1-B03 C — product datasheet (PDF)
- KA/KB-450BC1-B01I C — product datasheet (PDF)
- KA/KB-263BD1-B08 C — product datasheet (PDF)
- KA/KB-280GB5-B01I C — product datasheet (PDF)
- KA/KB-463BB5-B01 C — product datasheet (PDF)
- KA/KB-t-2x250EC5-B09 C — product datasheet (PDF)
- KA/KB-450CD5-B10 C — product datasheet (PDF)
- KA/KB-363AD5-B06I C — product datasheet (PDF)