- Catalogue
- Condensers
- KA/KB (General)
KA/KB (General)
- Refrigerants
- R134a, R22, R290, R32, R404A, R407A, R407B, R407C, R407F, R410A, R448A, R449A, R450a, R452a, R454A, R454C, R455A, R507A, R513a
- Capacity
- 14.80–1425.75 kW
- Fans
- ⌀500, ⌀630, ⌀800, ⌀910 mm
- Max. working pressure
- 27 bar
Model nomenclature
How to read the model codes of this series, with an example.
-
A
Series KA/KB = KA = vertical, KB = horizontal industrial condenser.
-
B
Fin type (optional "t") — = absent: standard corrugated finst = t: louvered fins (high-efficiency fin surface)
-
C
Fan rows (optional "Nx") — Catalogue: "Fan Row no." (number before x/X). — = absent: 1 fan row2x = 2 fan rows
-
D
Number of fans per row — Digit 1-9; total fans = fan rows x this digit.
-
E
Fan diameter — Two digits = diameter / 10 (91 = Ø910). 50 = Ø500 mm63 = Ø630 mm80 = Ø800 mm91 = Ø910 mm
-
G
Coil tube rows (2nd dimensional letter) A = 2 tube rowsB = 3 tube rowsC = 4 tube rowsD = 5 tube rows
-
H
Fin spacing — Catalogue fin-spacing code. 1 = 2.1 mm5 = 2.5 mm
-
I
Generation code — Catalogue: "Generation Code". B = generation B
-
J
Fan data (fan motor code) — Catalogue: "Fan Data". Two digits select the fan motor (supply, poles); the meaning is series-specific. 01 = fan motor code; supply/poles vary with diameter03 = three-phase 400 V 50 Hz, 12-pole AC fan (in this series)04 = fan motor code; supply/poles vary with diameter06 = three-phase 400 V 50 Hz, 6-pole AC fan (in this series)08 = three-phase 400 V 50 Hz, 4-pole AC fan (in this series)09 = single-phase 230 V 50 Hz, 4-pole AC fan (in this series)10 = three-phase 400 V 50 Hz, 4-pole AC fan (in this series)19 = three-phase 400 V 50 Hz, 4-pole AC fan (in this series)
| Model | Heat rejection [kW] i Nominal conditions (EN 327): air inlet 25 °C, condensing temperature 40 °C (ΔT 15 K), gas inlet superheat 26 K, no subcooling, relative humidity 50 % | Fans | Air flow [m³/h] | Variants |
|---|---|---|---|---|
| KA/KB-t-380EC1-B01 C | 186.67 kW | 3 × ⌀800 | 45,238 |
Variants (1) |
| KA/KB-t-750EC5-B09 C | 186.68 kW | 7 × ⌀500 | 46,447 |
Variants (1) |
| KA/KB-t-280LC5-B01 C | 186.68 kW | 2 × ⌀800 | 43,874 |
Variants (1) |
| KA/KB-t-291MB5-B04I C | 186.72 kW | 2 × ⌀910 | 60,739 |
Variants (1) |
| KA/KB-291HC5-B04 C | 186.72 kW | 2 × ⌀910 | 60,278 |
Variants (1) |
| KA/KB-380AC1-B01 C | 186.75 kW | 3 × ⌀800 | 51,714 |
Variants (1) |
| KA/KB-563BD1-B06I C | 186.83 kW | 5 × ⌀630 | 39,800 |
Variants (1) |
| KA/KB-291GD5-B04I C | 186.85 kW | 2 × ⌀910 | 52,407 |
Variants (1) |
| KA/KB-t-291MB5-B04 C | 186.91 kW | 2 × ⌀910 | 60,829 |
Variants (1) |
| KA/KB-280KD5-B01 C | 186.99 kW | 2 × ⌀800 | 43,830 |
Variants (1) |
| KA/KB-2x280CC5-B01I C | 187.06 kW | 4 × ⌀800 | 63,419 |
Variants (1) |
| KA/KB-2x450CC5-B01I C | 187.11 kW | 8 × ⌀500 | 56,185 |
Variants (1) |
| KA/KB-2x450AC1-B01I C | 187.16 kW | 8 × ⌀500 | 50,489 |
Variants (1) |
| KA/KB-t-2x550EA1-B09 C | 187.35 kW | 10 × ⌀500 | 72,352 |
Variants (1) |
| KA/KB-2x280GC1-B03 C | 187.53 kW | 4 × ⌀800 | 40,127 |
Variants (1) |
| KA/KB-563BD1-B01 C | 187.67 kW | 5 × ⌀630 | 39,999 |
Variants (1) |
| KA/KB-580AC5-B03 C | 187.91 kW | 5 × ⌀800 | 43,881 |
Variants (1) |
| KA/KB-t-580EA5-B01 C | 188.32 kW | 5 × ⌀800 | 96,842 |
Variants (1) |
| KA/KB-391BB5-B04 C | 188.34 kW | 3 × ⌀910 | 79,855 |
Variants (1) |
| KA/KB-t-2x450EB5-B10 C | 188.40 kW | 8 × ⌀500 | 57,107 |
Variants (1) |
| KA/KB-t-2x363EA5-B08 C | 188.40 kW | 6 × ⌀630 | 93,426 |
Variants (1) |
| KA/KB-391BB5-B04I C | 188.75 kW | 3 × ⌀910 | 80,168 |
Variants (1) |
| KA/KB-2x363BC5-B06I C | 188.81 kW | 6 × ⌀630 | 50,499 |
Variants (1) |
| KA/KB-680CC5-B03 C | 189.20 kW | 6 × ⌀800 | 49,909 |
Variants (1) |
| KA/KB-2x280FC1-B03 C | 189.20 kW | 4 × ⌀800 | 39,930 |
Variants (1) |
| KA/KB-480FC1-B03 C | 189.36 kW | 4 × ⌀800 | 39,930 |
Variants (1) |
| KA/KB-2x263FB5-B19 C | 189.71 kW | 4 × ⌀630 | 51,668 |
Variants (1) |
| KA/KB-2x280KB1-B03 C | 189.91 kW | 4 × ⌀800 | 44,784 |
Variants (1) |
| KA/KB-2x280JB5-B03 C | 189.93 kW | 4 × ⌀800 | 45,127 |
Variants (1) |
| KA/KB-563AB5-B08 C | 189.96 kW | 5 × ⌀630 | 75,560 |
Variants (1) |
| KA/KB-463FB5-B19 C | 189.96 kW | 4 × ⌀630 | 51,668 |
Variants (1) |
| KA/KB-2x280AB5-B01I C | 190.08 kW | 4 × ⌀800 | 71,017 |
Variants (1) |
| KA/KB-2x263BD1-B19 C | 190.12 kW | 4 × ⌀630 | 43,885 |
Variants (1) |
| KA/KB-480AB5-B01I C | 190.34 kW | 4 × ⌀800 | 71,017 |
Variants (1) |
| KA/KB-463BD1-B19 C | 190.63 kW | 4 × ⌀630 | 44,075 |
Variants (1) |
| KA/KB-2x180JD5-B01 C | 190.73 kW | 2 × ⌀800 | 43,558 |
Variants (1) |
| KA/KB-2x363BC5-B01 C | 190.76 kW | 6 × ⌀630 | 51,193 |
Variants (1) |
| KA/KB-t-2x380EB5-B03 C | 190.77 kW | 6 × ⌀800 | 50,703 |
Variants (1) |
| KA/KB-t-2x380EA5-B01I C | 190.89 kW | 6 × ⌀800 | 106,339 |
Variants (1) |
| KA/KB-663BC5-B06I C | 190.90 kW | 6 × ⌀630 | 50,683 |
Variants (1) |
| KA/KB-t-2x191LC5-B04 C | 190.92 kW | 2 × ⌀910 | 51,986 |
Variants (1) |
| KA/KB-t-750EC5-B10 C | 191.08 kW | 7 × ⌀500 | 47,767 |
Variants (1) |
| KA/KB-380FB5-B01 C | 191.09 kW | 3 × ⌀800 | 65,143 |
Variants (1) |
| KA/KB-463AD1-B19 C | 191.41 kW | 4 × ⌀630 | 43,662 |
Variants (1) |
| KA/KB-2x450AD5-B09 C | 191.42 kW | 8 × ⌀500 | 47,557 |
Variants (1) |
| KA/KB-t-2x191LC5-B04I C | 191.53 kW | 2 × ⌀910 | 52,219 |
Variants (1) |
| KA/KB-2x263BC1-B08 C | 191.65 kW | 4 × ⌀630 | 56,244 |
Variants (1) |
| KA/KB-480CC5-B01I C | 191.90 kW | 4 × ⌀800 | 63,824 |
Variants (1) |
| KA/KB-2x363BB5-B19 C | 191.99 kW | 6 × ⌀630 | 71,984 |
Variants (1) |
| KA/KB-2x263AD1-B19 C | 192.07 kW | 4 × ⌀630 | 43,662 |
Variants (1) |
Nominal conditions (EN 327): air inlet 25 °C, condensing temperature 40 °C (ΔT 15 K), gas inlet superheat 26 K, no subcooling, relative humidity 50 %
Downloads
- KA/KB-t-380EC1-B01 C — product datasheet (PDF)
- KA/KB-t-750EC5-B09 C — product datasheet (PDF)
- KA/KB-t-280LC5-B01 C — product datasheet (PDF)
- KA/KB-t-291MB5-B04I C — product datasheet (PDF)
- KA/KB-291HC5-B04 C — product datasheet (PDF)
- KA/KB-380AC1-B01 C — product datasheet (PDF)
- KA/KB-563BD1-B06I C — product datasheet (PDF)
- KA/KB-291GD5-B04I C — product datasheet (PDF)
- KA/KB-t-291MB5-B04 C — product datasheet (PDF)
- KA/KB-280KD5-B01 C — product datasheet (PDF)
- KA/KB-2x280CC5-B01I C — product datasheet (PDF)
- KA/KB-2x450CC5-B01I C — product datasheet (PDF)
- KA/KB-2x450AC1-B01I C — product datasheet (PDF)
- KA/KB-t-2x550EA1-B09 C — product datasheet (PDF)
- KA/KB-2x280GC1-B03 C — product datasheet (PDF)
- KA/KB-563BD1-B01 C — product datasheet (PDF)
- KA/KB-580AC5-B03 C — product datasheet (PDF)
- KA/KB-t-580EA5-B01 C — product datasheet (PDF)
- KA/KB-391BB5-B04 C — product datasheet (PDF)
- KA/KB-t-2x450EB5-B10 C — product datasheet (PDF)
- KA/KB-t-2x363EA5-B08 C — product datasheet (PDF)
- KA/KB-391BB5-B04I C — product datasheet (PDF)
- KA/KB-2x363BC5-B06I C — product datasheet (PDF)
- KA/KB-680CC5-B03 C — product datasheet (PDF)
- KA/KB-2x280FC1-B03 C — product datasheet (PDF)
- KA/KB-480FC1-B03 C — product datasheet (PDF)
- KA/KB-2x263FB5-B19 C — product datasheet (PDF)
- KA/KB-2x280KB1-B03 C — product datasheet (PDF)
- KA/KB-2x280JB5-B03 C — product datasheet (PDF)
- KA/KB-563AB5-B08 C — product datasheet (PDF)
- KA/KB-463FB5-B19 C — product datasheet (PDF)
- KA/KB-2x280AB5-B01I C — product datasheet (PDF)
- KA/KB-2x263BD1-B19 C — product datasheet (PDF)
- KA/KB-480AB5-B01I C — product datasheet (PDF)
- KA/KB-463BD1-B19 C — product datasheet (PDF)
- KA/KB-2x180JD5-B01 C — product datasheet (PDF)
- KA/KB-2x363BC5-B01 C — product datasheet (PDF)
- KA/KB-t-2x380EB5-B03 C — product datasheet (PDF)
- KA/KB-t-2x380EA5-B01I C — product datasheet (PDF)
- KA/KB-663BC5-B06I C — product datasheet (PDF)
- KA/KB-t-2x191LC5-B04 C — product datasheet (PDF)
- KA/KB-t-750EC5-B10 C — product datasheet (PDF)
- KA/KB-380FB5-B01 C — product datasheet (PDF)
- KA/KB-463AD1-B19 C — product datasheet (PDF)
- KA/KB-2x450AD5-B09 C — product datasheet (PDF)
- KA/KB-t-2x191LC5-B04I C — product datasheet (PDF)
- KA/KB-2x263BC1-B08 C — product datasheet (PDF)
- KA/KB-480CC5-B01I C — product datasheet (PDF)
- KA/KB-2x363BB5-B19 C — product datasheet (PDF)
- KA/KB-2x263AD1-B19 C — product datasheet (PDF)
Ask about product
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.