- Catalogue
- Condensers
- KA/KB (General)
KA/KB (General)
- Refrigerants
- R134a, R22, R290, R32, R404A, R407A, R407B, R407C, R407F, R410A, R448A, R449A, R450a, R452a, R454A, R454C, R455A, R507A, R513a
- Capacity
- 14.80–1425.75 kW
- Fans
- ⌀500, ⌀630, ⌀800, ⌀910 mm
- Max. working pressure
- 27 bar
Model nomenclature
How to read the model codes of this series, with an example.
-
A
Series KA/KB = KA = vertical, KB = horizontal industrial condenser.
-
B
Fin type (optional "t") — = absent: standard corrugated finst = t: louvered fins (high-efficiency fin surface)
-
C
Fan rows (optional "Nx") — Catalogue: "Fan Row no." (number before x/X). — = absent: 1 fan row2x = 2 fan rows
-
D
Number of fans per row — Digit 1-9; total fans = fan rows x this digit.
-
E
Fan diameter — Two digits = diameter / 10 (91 = Ø910). 50 = Ø500 mm63 = Ø630 mm80 = Ø800 mm91 = Ø910 mm
-
G
Coil tube rows (2nd dimensional letter) A = 2 tube rowsB = 3 tube rowsC = 4 tube rowsD = 5 tube rows
-
H
Fin spacing — Catalogue fin-spacing code. 1 = 2.1 mm5 = 2.5 mm
-
I
Generation code — Catalogue: "Generation Code". B = generation B
-
J
Fan data (fan motor code) — Catalogue: "Fan Data". Two digits select the fan motor (supply, poles); the meaning is series-specific. 01 = fan motor code; supply/poles vary with diameter03 = three-phase 400 V 50 Hz, 12-pole AC fan (in this series)04 = fan motor code; supply/poles vary with diameter06 = three-phase 400 V 50 Hz, 6-pole AC fan (in this series)08 = three-phase 400 V 50 Hz, 4-pole AC fan (in this series)09 = single-phase 230 V 50 Hz, 4-pole AC fan (in this series)10 = three-phase 400 V 50 Hz, 4-pole AC fan (in this series)19 = three-phase 400 V 50 Hz, 4-pole AC fan (in this series)
| Model | Heat rejection [kW] i Nominal conditions (EN 327): air inlet 25 °C, condensing temperature 40 °C (ΔT 15 K), gas inlet superheat 26 K, no subcooling, relative humidity 50 % | Fans | Air flow [m³/h] | Variants |
|---|---|---|---|---|
| KA/KB-463FB1-B19 C | 203.66 kW | 4 × ⌀630 | 51,444 |
Variants (1) |
| KA/KB-2x550BC1-B04 C | 203.77 kW | 10 × ⌀500 | 46,645 |
Variants (1) |
| KA/KB-363GC1-B08 C | 203.84 kW | 3 × ⌀630 | 49,570 |
Variants (1) |
| KA/KB-2x450AD1-B01I C | 203.91 kW | 8 × ⌀500 | 47,510 |
Variants (1) |
| KA/KB-2x450CC1-B10 C | 204.12 kW | 8 × ⌀500 | 55,367 |
Variants (1) |
| KA/KB-2x191CD1-B04I C | 204.25 kW | 2 × ⌀910 | 50,356 |
Variants (1) |
| KA/KB-291GD1-B04I C | 204.26 kW | 2 × ⌀910 | 51,022 |
Variants (1) |
| KA/KB-2x263AD5-B08 C | 204.37 kW | 4 × ⌀630 | 54,518 |
Variants (1) |
| KA/KB-t-480EB1-B01 C | 204.44 kW | 4 × ⌀800 | 66,781 |
Variants (1) |
| KA/KB-2x450CC1-B01I C | 204.62 kW | 8 × ⌀500 | 55,120 |
Variants (1) |
| KA/KB-2x550BB5-B10 C | 204.66 kW | 10 × ⌀500 | 73,180 |
Variants (1) |
| KA/KB-t-580EA1-B01I C | 204.68 kW | 5 × ⌀800 | 87,145 |
Variants (1) |
| KA/KB-2x363BC1-B06I C | 204.70 kW | 6 × ⌀630 | 49,602 |
Variants (1) |
| KA/KB-463AD5-B08 C | 204.77 kW | 4 × ⌀630 | 54,518 |
Variants (1) |
| KA/KB-391BB1-B04 C | 204.94 kW | 3 × ⌀910 | 77,814 |
Variants (1) |
| KA/KB-2x550BB5-B01I C | 205.38 kW | 10 × ⌀500 | 72,848 |
Variants (1) |
| KA/KB-2x363AB5-B19 C | 205.39 kW | 6 × ⌀630 | 71,779 |
Variants (1) |
| KA/KB-391BB1-B04I C | 205.48 kW | 3 × ⌀910 | 78,164 |
Variants (1) |
| KA/KB-t-2x450EB1-B10 C | 205.73 kW | 8 × ⌀500 | 56,086 |
Variants (1) |
| KA/KB-2x280AB1-B01I C | 205.78 kW | 4 × ⌀800 | 69,509 |
Variants (1) |
| KA/KB-363FC1-B08 C | 205.89 kW | 3 × ⌀630 | 49,354 |
Variants (1) |
| KA/KB-t-2x280EB1-B01I C | 205.91 kW | 4 × ⌀800 | 62,795 |
Variants (1) |
| KA/KB-480AB1-B01I C | 206.11 kW | 4 × ⌀800 | 69,509 |
Variants (1) |
| KA/KB-t-750EC1-B10 C | 206.29 kW | 7 × ⌀500 | 46,768 |
Variants (1) |
| KA/KB-t-2x463EA5-B19 C | 206.29 kW | 8 × ⌀630 | 97,823 |
Variants (1) |
| KA/KB-291CD1-B04 C | 206.52 kW | 2 × ⌀910 | 50,136 |
Variants (1) |
| KA/KB-2x363BC1-B01 C | 206.57 kW | 6 × ⌀630 | 50,168 |
Variants (1) |
| KA/KB-380FB1-B01 C | 206.71 kW | 3 × ⌀800 | 64,196 |
Variants (1) |
| KA/KB-580FB5-B03 C | 206.91 kW | 5 × ⌀800 | 53,473 |
Variants (1) |
| KA/KB-291CD1-B04I C | 207.23 kW | 2 × ⌀910 | 50,356 |
Variants (1) |
| KA/KB-563AB1-B08 C | 207.76 kW | 5 × ⌀630 | 74,178 |
Variants (1) |
| KA/KB-t-2x550EB5-B09 C | 207.86 kW | 10 × ⌀500 | 69,486 |
Variants (1) |
| KA/KB-t-2x650EB5-B04 C | 207.89 kW | 12 × ⌀500 | 58,542 |
Variants (1) |
| KA/KB-663BC1-B01 C | 207.90 kW | 6 × ⌀630 | 50,391 |
Variants (1) |
| KA/KB-680CC1-B03 C | 207.93 kW | 6 × ⌀800 | 48,143 |
Variants (1) |
| KA/KB-380GC1-B01I C | 208.29 kW | 3 × ⌀800 | 55,960 |
Variants (1) |
| KA/KB-463FB5-B08 C | 208.33 kW | 4 × ⌀630 | 67,832 |
Variants (1) |
| KA/KB-2x280CC1-B01I C | 208.56 kW | 4 × ⌀800 | 61,466 |
Variants (1) |
| KA/KB-t-2x380HA5-B03 C | 208.65 kW | 6 × ⌀800 | 65,505 |
Variants (1) |
| KA/KB-t-2x380EB1-B03 C | 208.71 kW | 6 × ⌀800 | 48,958 |
Variants (1) |
| KA/KB-380FC5-B01I C | 208.85 kW | 3 × ⌀800 | 56,442 |
Variants (1) |
| KA/KB-t-2x191MB1-B04I C | 208.93 kW | 2 × ⌀910 | 59,689 |
Variants (1) |
| KA/KB-t-2x191MB1-B04 C | 209.10 kW | 2 × ⌀910 | 59,754 |
Variants (1) |
| KA/KB-2x450BC1-B10 C | 209.11 kW | 8 × ⌀500 | 54,815 |
Variants (1) |
| KA/KB-2x450BC1-B09 C | 209.34 kW | 8 × ⌀500 | 53,329 |
Variants (1) |
| KA/KB-2x450CD5-B09 C | 209.37 kW | 8 × ⌀500 | 52,625 |
Variants (1) |
| KA/KB-563FB1-B01 C | 209.40 kW | 5 × ⌀630 | 49,506 |
Variants (1) |
| KA/KB-291HC1-B04I C | 209.51 kW | 2 × ⌀910 | 59,266 |
Variants (1) |
| KA/KB-291HC1-B04 C | 209.55 kW | 2 × ⌀910 | 59,282 |
Variants (1) |
| KA/KB-2x463BB5-B06I C | 209.58 kW | 8 × ⌀630 | 70,132 |
Variants (1) |
Nominal conditions (EN 327): air inlet 25 °C, condensing temperature 40 °C (ΔT 15 K), gas inlet superheat 26 K, no subcooling, relative humidity 50 %
Downloads
- KA/KB-463FB1-B19 C — product datasheet (PDF)
- KA/KB-2x550BC1-B04 C — product datasheet (PDF)
- KA/KB-363GC1-B08 C — product datasheet (PDF)
- KA/KB-2x450AD1-B01I C — product datasheet (PDF)
- KA/KB-2x450CC1-B10 C — product datasheet (PDF)
- KA/KB-2x191CD1-B04I C — product datasheet (PDF)
- KA/KB-291GD1-B04I C — product datasheet (PDF)
- KA/KB-2x263AD5-B08 C — product datasheet (PDF)
- KA/KB-t-480EB1-B01 C — product datasheet (PDF)
- KA/KB-2x450CC1-B01I C — product datasheet (PDF)
- KA/KB-2x550BB5-B10 C — product datasheet (PDF)
- KA/KB-t-580EA1-B01I C — product datasheet (PDF)
- KA/KB-2x363BC1-B06I C — product datasheet (PDF)
- KA/KB-463AD5-B08 C — product datasheet (PDF)
- KA/KB-391BB1-B04 C — product datasheet (PDF)
- KA/KB-2x550BB5-B01I C — product datasheet (PDF)
- KA/KB-2x363AB5-B19 C — product datasheet (PDF)
- KA/KB-391BB1-B04I C — product datasheet (PDF)
- KA/KB-t-2x450EB1-B10 C — product datasheet (PDF)
- KA/KB-2x280AB1-B01I C — product datasheet (PDF)
- KA/KB-363FC1-B08 C — product datasheet (PDF)
- KA/KB-t-2x280EB1-B01I C — product datasheet (PDF)
- KA/KB-480AB1-B01I C — product datasheet (PDF)
- KA/KB-t-750EC1-B10 C — product datasheet (PDF)
- KA/KB-t-2x463EA5-B19 C — product datasheet (PDF)
- KA/KB-291CD1-B04 C — product datasheet (PDF)
- KA/KB-2x363BC1-B01 C — product datasheet (PDF)
- KA/KB-380FB1-B01 C — product datasheet (PDF)
- KA/KB-580FB5-B03 C — product datasheet (PDF)
- KA/KB-291CD1-B04I C — product datasheet (PDF)
- KA/KB-563AB1-B08 C — product datasheet (PDF)
- KA/KB-t-2x550EB5-B09 C — product datasheet (PDF)
- KA/KB-t-2x650EB5-B04 C — product datasheet (PDF)
- KA/KB-663BC1-B01 C — product datasheet (PDF)
- KA/KB-680CC1-B03 C — product datasheet (PDF)
- KA/KB-380GC1-B01I C — product datasheet (PDF)
- KA/KB-463FB5-B08 C — product datasheet (PDF)
- KA/KB-2x280CC1-B01I C — product datasheet (PDF)
- KA/KB-t-2x380HA5-B03 C — product datasheet (PDF)
- KA/KB-t-2x380EB1-B03 C — product datasheet (PDF)
- KA/KB-380FC5-B01I C — product datasheet (PDF)
- KA/KB-t-2x191MB1-B04I C — product datasheet (PDF)
- KA/KB-t-2x191MB1-B04 C — product datasheet (PDF)
- KA/KB-2x450BC1-B10 C — product datasheet (PDF)
- KA/KB-2x450BC1-B09 C — product datasheet (PDF)
- KA/KB-2x450CD5-B09 C — product datasheet (PDF)
- KA/KB-563FB1-B01 C — product datasheet (PDF)
- KA/KB-291HC1-B04I C — product datasheet (PDF)
- KA/KB-291HC1-B04 C — product datasheet (PDF)
- KA/KB-2x463BB5-B06I C — product datasheet (PDF)
Ask about product
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.