- Catalogue
- Condensers
- KA/KB (General)
KA/KB (General)
- Refrigerants
- R134a, R22, R290, R32, R404A, R407A, R407B, R407C, R407F, R410A, R448A, R449A, R450a, R452a, R454A, R454C, R455A, R507A, R513a
- Capacity
- 14.80–1425.75 kW
- Fans
- ⌀500, ⌀630, ⌀800, ⌀910 mm
- Max. working pressure
- 27 bar
Model nomenclature
How to read the model codes of this series, with an example.
-
A
Series KA/KB = KA = vertical, KB = horizontal industrial condenser.
-
B
Fin type (optional "t") — = absent: standard corrugated finst = t: louvered fins (high-efficiency fin surface)
-
C
Fan rows (optional "Nx") — Catalogue: "Fan Row no." (number before x/X). — = absent: 1 fan row2x = 2 fan rows
-
D
Number of fans per row — Digit 1-9; total fans = fan rows x this digit.
-
E
Fan diameter — Two digits = diameter / 10 (91 = Ø910). 50 = Ø500 mm63 = Ø630 mm80 = Ø800 mm91 = Ø910 mm
-
G
Coil tube rows (2nd dimensional letter) A = 2 tube rowsB = 3 tube rowsC = 4 tube rowsD = 5 tube rows
-
H
Fin spacing — Catalogue fin-spacing code. 1 = 2.1 mm5 = 2.5 mm
-
I
Generation code — Catalogue: "Generation Code". B = generation B
-
J
Fan data (fan motor code) — Catalogue: "Fan Data". Two digits select the fan motor (supply, poles); the meaning is series-specific. 01 = fan motor code; supply/poles vary with diameter03 = three-phase 400 V 50 Hz, 12-pole AC fan (in this series)04 = fan motor code; supply/poles vary with diameter06 = three-phase 400 V 50 Hz, 6-pole AC fan (in this series)08 = three-phase 400 V 50 Hz, 4-pole AC fan (in this series)09 = single-phase 230 V 50 Hz, 4-pole AC fan (in this series)10 = three-phase 400 V 50 Hz, 4-pole AC fan (in this series)19 = three-phase 400 V 50 Hz, 4-pole AC fan (in this series)
| Model | Heat rejection [kW] i Nominal conditions (EN 327): air inlet 25 °C, condensing temperature 40 °C (ΔT 15 K), gas inlet superheat 26 K, no subcooling, relative humidity 50 % | Fans | Air flow [m³/h] | Variants |
|---|---|---|---|---|
| KA/KB-2x550BB1-B10 C | 221.83 kW | 10 × ⌀500 | 71,993 |
Variants (1) |
| KA/KB-463FC5-B19 C | 221.85 kW | 4 × ⌀630 | 51,024 |
Variants (1) |
| KA/KB-563BD5-B19 C | 221.96 kW | 5 × ⌀630 | 56,107 |
Variants (1) |
| KA/KB-2x450BD5-B01I C | 222.05 kW | 8 × ⌀500 | 53,305 |
Variants (1) |
| KA/KB-2x550BB1-B01I C | 222.69 kW | 10 × ⌀500 | 71,686 |
Variants (1) |
| KA/KB-2x363AB1-B19 C | 222.80 kW | 6 × ⌀630 | 70,894 |
Variants (1) |
| KA/KB-t-380HC5-B01I C | 222.94 kW | 3 × ⌀800 | 55,022 |
Variants (1) |
| KA/KB-580CB1-B01 C | 223.05 kW | 5 × ⌀800 | 89,010 |
Variants (1) |
| KA/KB-2x380GB5-B03 C | 223.17 kW | 6 × ⌀800 | 64,368 |
Variants (1) |
| KA/KB-480CD5-B01 C | 223.40 kW | 4 × ⌀800 | 62,568 |
Variants (1) |
| KA/KB-391CB5-B04 C | 223.45 kW | 3 × ⌀910 | 86,071 |
Variants (1) |
| KA/KB-2x191DC1-B04 C | 223.77 kW | 2 × ⌀910 | 58,796 |
Variants (1) |
| KA/KB-391CB5-B04I C | 223.80 kW | 3 × ⌀910 | 86,309 |
Variants (1) |
| KA/KB-2x191DC1-B04I C | 223.86 kW | 2 × ⌀910 | 58,827 |
Variants (1) |
| KA/KB-t-2x363HA1-B01 C | 224.01 kW | 6 × ⌀630 | 60,122 |
Variants (1) |
| KA/KB-291DC1-B04 C | 224.02 kW | 2 × ⌀910 | 58,796 |
Variants (1) |
| KA/KB-2x280AC5-B01I C | 224.08 kW | 4 × ⌀800 | 66,782 |
Variants (1) |
| KA/KB-391BC5-B04 C | 224.11 kW | 3 × ⌀910 | 74,241 |
Variants (1) |
| KA/KB-291DC1-B04I C | 224.11 kW | 2 × ⌀910 | 58,827 |
Variants (1) |
| KA/KB-2x363BD1-B06I C | 224.20 kW | 6 × ⌀630 | 47,535 |
Variants (1) |
| KA/KB-480AC5-B01I C | 224.32 kW | 4 × ⌀800 | 66,782 |
Variants (1) |
| KA/KB-380GC1-B01 C | 224.38 kW | 3 × ⌀800 | 61,675 |
Variants (1) |
| KA/KB-380FC5-B01 C | 224.42 kW | 3 × ⌀800 | 62,334 |
Variants (1) |
| KA/KB-391BC5-B04I C | 224.78 kW | 3 × ⌀910 | 74,592 |
Variants (1) |
| KA/KB-580FC5-B03 C | 224.84 kW | 5 × ⌀800 | 50,894 |
Variants (1) |
| KA/KB-2x363AB5-B08 C | 224.86 kW | 6 × ⌀630 | 90,672 |
Variants (1) |
| KA/KB-t-563EC1-B19 C | 224.96 kW | 5 × ⌀630 | 55,172 |
Variants (1) |
| KA/KB-t-2x480EA1-B03 C | 225.11 kW | 8 × ⌀800 | 73,656 |
Variants (1) |
| KA/KB-t-2x263HB1-B19 C | 225.57 kW | 4 × ⌀630 | 51,002 |
Variants (1) |
| KA/KB-463FB1-B08 C | 225.63 kW | 4 × ⌀630 | 67,337 |
Variants (1) |
| KA/KB-563FC1-B01 C | 225.75 kW | 5 × ⌀630 | 48,547 |
Variants (1) |
| KA/KB-2x191HD5-B04 C | 225.76 kW | 2 × ⌀910 | 57,895 |
Variants (1) |
| KA/KB-2x291FB5-B04 C | 225.83 kW | 4 × ⌀910 | 107,116 |
Variants (1) |
| KA/KB-t-380HB1-B01 C | 225.90 kW | 3 × ⌀800 | 62,492 |
Variants (1) |
| KA/KB-2x450CD1-B09 C | 226.02 kW | 8 × ⌀500 | 51,358 |
Variants (1) |
| KA/KB-480FB5-B01I C | 226.08 kW | 4 × ⌀800 | 78,091 |
Variants (1) |
| KA/KB-2x191HD5-B04I C | 226.09 kW | 2 × ⌀910 | 58,010 |
Variants (1) |
| KA/KB-2x450BD1-B09 C | 226.23 kW | 8 × ⌀500 | 50,691 |
Variants (1) |
| KA/KB-2x463AB5-B06I C | 226.23 kW | 8 × ⌀630 | 69,901 |
Variants (1) |
| KA/KB-2x291FB5-B04I C | 226.32 kW | 4 × ⌀910 | 107,515 |
Variants (1) |
| KA/KB-t-291MC5-B04 C | 226.55 kW | 2 × ⌀910 | 58,214 |
Variants (1) |
| KA/KB-2x380AC5-B03 C | 226.57 kW | 6 × ⌀800 | 52,657 |
Variants (1) |
| KA/KB-563AC5-B08 C | 226.76 kW | 5 × ⌀630 | 71,553 |
Variants (1) |
| KA/KB-t-291MC5-B04I C | 226.81 kW | 2 × ⌀910 | 58,301 |
Variants (1) |
| KA/KB-680AC5-B03 C | 226.81 kW | 6 × ⌀800 | 52,657 |
Variants (1) |
| KA/KB-663BC5-B19 C | 226.81 kW | 6 × ⌀630 | 69,700 |
Variants (1) |
| KA/KB-780AB5-B03 C | 226.90 kW | 7 × ⌀800 | 66,345 |
Variants (1) |
| KA/KB-t-2x380EA1-B01 C | 226.99 kW | 6 × ⌀800 | 112,211 |
Variants (1) |
| KA/KB-2x280GB5-B01 C | 227.31 kW | 4 × ⌀800 | 87,152 |
Variants (1) |
| KA/KB-2x263GB1-B08 C | 227.61 kW | 4 × ⌀630 | 67,463 |
Variants (1) |
Nominal conditions (EN 327): air inlet 25 °C, condensing temperature 40 °C (ΔT 15 K), gas inlet superheat 26 K, no subcooling, relative humidity 50 %
Downloads
- KA/KB-2x550BB1-B10 C — product datasheet (PDF)
- KA/KB-463FC5-B19 C — product datasheet (PDF)
- KA/KB-563BD5-B19 C — product datasheet (PDF)
- KA/KB-2x450BD5-B01I C — product datasheet (PDF)
- KA/KB-2x550BB1-B01I C — product datasheet (PDF)
- KA/KB-2x363AB1-B19 C — product datasheet (PDF)
- KA/KB-t-380HC5-B01I C — product datasheet (PDF)
- KA/KB-580CB1-B01 C — product datasheet (PDF)
- KA/KB-2x380GB5-B03 C — product datasheet (PDF)
- KA/KB-480CD5-B01 C — product datasheet (PDF)
- KA/KB-391CB5-B04 C — product datasheet (PDF)
- KA/KB-2x191DC1-B04 C — product datasheet (PDF)
- KA/KB-391CB5-B04I C — product datasheet (PDF)
- KA/KB-2x191DC1-B04I C — product datasheet (PDF)
- KA/KB-t-2x363HA1-B01 C — product datasheet (PDF)
- KA/KB-291DC1-B04 C — product datasheet (PDF)
- KA/KB-2x280AC5-B01I C — product datasheet (PDF)
- KA/KB-391BC5-B04 C — product datasheet (PDF)
- KA/KB-291DC1-B04I C — product datasheet (PDF)
- KA/KB-2x363BD1-B06I C — product datasheet (PDF)
- KA/KB-480AC5-B01I C — product datasheet (PDF)
- KA/KB-380GC1-B01 C — product datasheet (PDF)
- KA/KB-380FC5-B01 C — product datasheet (PDF)
- KA/KB-391BC5-B04I C — product datasheet (PDF)
- KA/KB-580FC5-B03 C — product datasheet (PDF)
- KA/KB-2x363AB5-B08 C — product datasheet (PDF)
- KA/KB-t-563EC1-B19 C — product datasheet (PDF)
- KA/KB-t-2x480EA1-B03 C — product datasheet (PDF)
- KA/KB-t-2x263HB1-B19 C — product datasheet (PDF)
- KA/KB-463FB1-B08 C — product datasheet (PDF)
- KA/KB-563FC1-B01 C — product datasheet (PDF)
- KA/KB-2x191HD5-B04 C — product datasheet (PDF)
- KA/KB-2x291FB5-B04 C — product datasheet (PDF)
- KA/KB-t-380HB1-B01 C — product datasheet (PDF)
- KA/KB-2x450CD1-B09 C — product datasheet (PDF)
- KA/KB-480FB5-B01I C — product datasheet (PDF)
- KA/KB-2x191HD5-B04I C — product datasheet (PDF)
- KA/KB-2x450BD1-B09 C — product datasheet (PDF)
- KA/KB-2x463AB5-B06I C — product datasheet (PDF)
- KA/KB-2x291FB5-B04I C — product datasheet (PDF)
- KA/KB-t-291MC5-B04 C — product datasheet (PDF)
- KA/KB-2x380AC5-B03 C — product datasheet (PDF)
- KA/KB-563AC5-B08 C — product datasheet (PDF)
- KA/KB-t-291MC5-B04I C — product datasheet (PDF)
- KA/KB-680AC5-B03 C — product datasheet (PDF)
- KA/KB-663BC5-B19 C — product datasheet (PDF)
- KA/KB-780AB5-B03 C — product datasheet (PDF)
- KA/KB-t-2x380EA1-B01 C — product datasheet (PDF)
- KA/KB-2x280GB5-B01 C — product datasheet (PDF)
- KA/KB-2x263GB1-B08 C — product datasheet (PDF)
Ask about product
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.