- Catalogue
- Condensers
- KA/KB (General)
KA/KB (General)
- Refrigerants
- R134a, R22, R290, R32, R404A, R407A, R407B, R407C, R407F, R410A, R448A, R449A, R450a, R452a, R454A, R454C, R455A, R507A, R513a
- Capacity
- 14.80–1425.75 kW
- Fans
- ⌀500, ⌀630, ⌀800, ⌀910 mm
- Max. working pressure
- 27 bar
Model nomenclature
How to read the model codes of this series, with an example.
-
A
Series KA/KB = KA = vertical, KB = horizontal industrial condenser.
-
B
Fin type (optional "t") — = absent: standard corrugated finst = t: louvered fins (high-efficiency fin surface)
-
C
Fan rows (optional "Nx") — Catalogue: "Fan Row no." (number before x/X). — = absent: 1 fan row2x = 2 fan rows
-
D
Number of fans per row — Digit 1-9; total fans = fan rows x this digit.
-
E
Fan diameter — Two digits = diameter / 10 (91 = Ø910). 50 = Ø500 mm63 = Ø630 mm80 = Ø800 mm91 = Ø910 mm
-
G
Coil tube rows (2nd dimensional letter) A = 2 tube rowsB = 3 tube rowsC = 4 tube rowsD = 5 tube rows
-
H
Fin spacing — Catalogue fin-spacing code. 1 = 2.1 mm5 = 2.5 mm
-
I
Generation code — Catalogue: "Generation Code". B = generation B
-
J
Fan data (fan motor code) — Catalogue: "Fan Data". Two digits select the fan motor (supply, poles); the meaning is series-specific. 01 = fan motor code; supply/poles vary with diameter03 = three-phase 400 V 50 Hz, 12-pole AC fan (in this series)04 = fan motor code; supply/poles vary with diameter06 = three-phase 400 V 50 Hz, 6-pole AC fan (in this series)08 = three-phase 400 V 50 Hz, 4-pole AC fan (in this series)09 = single-phase 230 V 50 Hz, 4-pole AC fan (in this series)10 = three-phase 400 V 50 Hz, 4-pole AC fan (in this series)19 = three-phase 400 V 50 Hz, 4-pole AC fan (in this series)
| Model | Heat rejection [kW] i Nominal conditions (EN 327): air inlet 25 °C, condensing temperature 40 °C (ΔT 15 K), gas inlet superheat 26 K, no subcooling, relative humidity 50 % | Fans | Air flow [m³/h] | Variants |
|---|---|---|---|---|
| KA/KB-291HD5-B04I C | 235.58 kW | 2 × ⌀910 | 58,226 |
Variants (1) |
| KA/KB-t-2x380HA1-B03 C | 235.82 kW | 6 × ⌀800 | 64,732 |
Variants (1) |
| KA/KB-t-2x263HB5-B08 C | 235.88 kW | 4 × ⌀630 | 66,939 |
Variants (1) |
| KA/KB-t-391LB5-B04 C | 236.02 kW | 3 × ⌀910 | 83,396 |
Variants (1) |
| KA/KB-2x191DD5-B04 C | 236.07 kW | 2 × ⌀910 | 57,623 |
Variants (1) |
| KA/KB-680CB5-B01I C | 236.14 kW | 6 × ⌀800 | 102,755 |
Variants (1) |
| KA/KB-t-480EC1-B01 C | 236.29 kW | 4 × ⌀800 | 60,317 |
Variants (1) |
| KA/KB-t-2x450EC1-B10 C | 236.30 kW | 8 × ⌀500 | 53,066 |
Variants (1) |
| KA/KB-291DD5-B04 C | 236.31 kW | 2 × ⌀910 | 57,623 |
Variants (1) |
| KA/KB-2x191DD5-B04I C | 236.51 kW | 2 × ⌀910 | 57,761 |
Variants (1) |
| KA/KB-2x550CC5-B10 C | 236.54 kW | 10 × ⌀500 | 70,529 |
Variants (1) |
| KA/KB-t-391LB5-B04I C | 236.69 kW | 3 × ⌀910 | 83,766 |
Variants (1) |
| KA/KB-291DD5-B04I C | 236.75 kW | 2 × ⌀910 | 57,761 |
Variants (1) |
| KA/KB-2x463BB1-B01 C | 237.03 kW | 8 × ⌀630 | 70,413 |
Variants (1) |
| KA/KB-2x263FB1-B08 C | 237.07 kW | 4 × ⌀630 | 67,337 |
Variants (1) |
| KA/KB-2x280GB1-B01I C | 237.14 kW | 4 × ⌀800 | 77,343 |
Variants (1) |
| KA/KB-391GC5-B04 C | 237.40 kW | 3 × ⌀910 | 82,250 |
Variants (1) |
| KA/KB-2x363FB5-B01 C | 237.73 kW | 6 × ⌀630 | 59,776 |
Variants (1) |
| KA/KB-2x550CC5-B01I C | 237.78 kW | 10 × ⌀500 | 70,231 |
Variants (1) |
| KA/KB-2x280AC1-B01I C | 237.81 kW | 4 × ⌀800 | 65,003 |
Variants (1) |
| KA/KB-t-2x463EA1-B19 C | 237.90 kW | 8 × ⌀630 | 96,814 |
Variants (1) |
| KA/KB-2x280FB5-B01I C | 237.93 kW | 4 × ⌀800 | 78,091 |
Variants (1) |
| KA/KB-391GC5-B04I C | 238.02 kW | 3 × ⌀910 | 82,575 |
Variants (1) |
| KA/KB-380FC1-B01 C | 238.03 kW | 3 × ⌀800 | 61,103 |
Variants (1) |
| KA/KB-480AC1-B01I C | 238.10 kW | 4 × ⌀800 | 65,003 |
Variants (1) |
| KA/KB-t-2x280EC1-B01I C | 238.29 kW | 4 × ⌀800 | 57,300 |
Variants (1) |
| KA/KB-t-580EB5-B01 C | 238.95 kW | 5 × ⌀800 | 86,295 |
Variants (1) |
| KA/KB-380FD1-B01I C | 239.16 kW | 3 × ⌀800 | 53,451 |
Variants (1) |
| KA/KB-391BC1-B04 C | 239.25 kW | 3 × ⌀910 | 71,941 |
Variants (1) |
| KA/KB-580CC5-B01 C | 239.34 kW | 5 × ⌀800 | 84,451 |
Variants (1) |
| KA/KB-2x550AD5-B09 C | 239.45 kW | 10 × ⌀500 | 59,446 |
Variants (1) |
| KA/KB-580AB1-B01I C | 239.62 kW | 5 × ⌀800 | 86,886 |
Variants (1) |
| KA/KB-563BD1-B19 C | 239.76 kW | 5 × ⌀630 | 55,094 |
Variants (1) |
| KA/KB-391BC1-B04I C | 240.05 kW | 3 × ⌀910 | 72,294 |
Variants (1) |
| KA/KB-391FD5-B04 C | 240.07 kW | 3 × ⌀910 | 70,605 |
Variants (1) |
| KA/KB-t-380HC5-B01 C | 240.17 kW | 3 × ⌀800 | 60,411 |
Variants (1) |
| KA/KB-563AD1-B19 C | 240.35 kW | 5 × ⌀630 | 54,577 |
Variants (1) |
| KA/KB-391FD5-B04I C | 240.63 kW | 3 × ⌀910 | 70,845 |
Variants (1) |
| KA/KB-t-2x550EB1-B10 C | 240.63 kW | 10 × ⌀500 | 70,107 |
Variants (1) |
| KA/KB-2x280CD1-B01 C | 240.97 kW | 4 × ⌀800 | 59,620 |
Variants (1) |
| KA/KB-780AB1-B03 C | 241.93 kW | 7 × ⌀800 | 64,597 |
Variants (1) |
| KA/KB-t-380HC1-B01I C | 241.94 kW | 3 × ⌀800 | 54,018 |
Variants (1) |
| KA/KB-t-2x750EA5-B09 C | 242.04 kW | 14 × ⌀500 | 102,572 |
Variants (1) |
| KA/KB-480FB5-B01 C | 242.11 kW | 4 × ⌀800 | 86,857 |
Variants (1) |
| KA/KB-2x363GB1-B01 C | 242.38 kW | 6 × ⌀630 | 59,501 |
Variants (1) |
| KA/KB-391CB1-B04 C | 242.39 kW | 3 × ⌀910 | 84,312 |
Variants (1) |
| KA/KB-563AC1-B08 C | 242.58 kW | 5 × ⌀630 | 69,889 |
Variants (1) |
| KA/KB-391CB1-B04I C | 243.02 kW | 3 × ⌀910 | 84,680 |
Variants (1) |
| KA/KB-t-2x363EB5-B08 C | 243.29 kW | 6 × ⌀630 | 87,622 |
Variants (1) |
| KA/KB-2x480CB1-B03 C | 243.29 kW | 8 × ⌀800 | 69,814 |
Variants (1) |
Nominal conditions (EN 327): air inlet 25 °C, condensing temperature 40 °C (ΔT 15 K), gas inlet superheat 26 K, no subcooling, relative humidity 50 %
Downloads
- KA/KB-291HD5-B04I C — product datasheet (PDF)
- KA/KB-t-2x380HA1-B03 C — product datasheet (PDF)
- KA/KB-t-2x263HB5-B08 C — product datasheet (PDF)
- KA/KB-t-391LB5-B04 C — product datasheet (PDF)
- KA/KB-2x191DD5-B04 C — product datasheet (PDF)
- KA/KB-680CB5-B01I C — product datasheet (PDF)
- KA/KB-t-480EC1-B01 C — product datasheet (PDF)
- KA/KB-t-2x450EC1-B10 C — product datasheet (PDF)
- KA/KB-291DD5-B04 C — product datasheet (PDF)
- KA/KB-2x191DD5-B04I C — product datasheet (PDF)
- KA/KB-2x550CC5-B10 C — product datasheet (PDF)
- KA/KB-t-391LB5-B04I C — product datasheet (PDF)
- KA/KB-291DD5-B04I C — product datasheet (PDF)
- KA/KB-2x463BB1-B01 C — product datasheet (PDF)
- KA/KB-2x263FB1-B08 C — product datasheet (PDF)
- KA/KB-2x280GB1-B01I C — product datasheet (PDF)
- KA/KB-391GC5-B04 C — product datasheet (PDF)
- KA/KB-2x363FB5-B01 C — product datasheet (PDF)
- KA/KB-2x550CC5-B01I C — product datasheet (PDF)
- KA/KB-2x280AC1-B01I C — product datasheet (PDF)
- KA/KB-t-2x463EA1-B19 C — product datasheet (PDF)
- KA/KB-2x280FB5-B01I C — product datasheet (PDF)
- KA/KB-391GC5-B04I C — product datasheet (PDF)
- KA/KB-380FC1-B01 C — product datasheet (PDF)
- KA/KB-480AC1-B01I C — product datasheet (PDF)
- KA/KB-t-2x280EC1-B01I C — product datasheet (PDF)
- KA/KB-t-580EB5-B01 C — product datasheet (PDF)
- KA/KB-380FD1-B01I C — product datasheet (PDF)
- KA/KB-391BC1-B04 C — product datasheet (PDF)
- KA/KB-580CC5-B01 C — product datasheet (PDF)
- KA/KB-2x550AD5-B09 C — product datasheet (PDF)
- KA/KB-580AB1-B01I C — product datasheet (PDF)
- KA/KB-563BD1-B19 C — product datasheet (PDF)
- KA/KB-391BC1-B04I C — product datasheet (PDF)
- KA/KB-391FD5-B04 C — product datasheet (PDF)
- KA/KB-t-380HC5-B01 C — product datasheet (PDF)
- KA/KB-563AD1-B19 C — product datasheet (PDF)
- KA/KB-391FD5-B04I C — product datasheet (PDF)
- KA/KB-t-2x550EB1-B10 C — product datasheet (PDF)
- KA/KB-2x280CD1-B01 C — product datasheet (PDF)
- KA/KB-780AB1-B03 C — product datasheet (PDF)
- KA/KB-t-380HC1-B01I C — product datasheet (PDF)
- KA/KB-t-2x750EA5-B09 C — product datasheet (PDF)
- KA/KB-480FB5-B01 C — product datasheet (PDF)
- KA/KB-2x363GB1-B01 C — product datasheet (PDF)
- KA/KB-391CB1-B04 C — product datasheet (PDF)
- KA/KB-563AC1-B08 C — product datasheet (PDF)
- KA/KB-391CB1-B04I C — product datasheet (PDF)
- KA/KB-t-2x363EB5-B08 C — product datasheet (PDF)
- KA/KB-2x480CB1-B03 C — product datasheet (PDF)
Ask about product
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.