KC-MF (Modular V-type with chassis)
- Refrigerants
- R134a, R22, R290, R32, R404A, R407A, R407B, R407C, R407F, R410A, R448A, R449A, R450a, R452a, R454A, R454C, R455A, R507A, R513a
- Capacity
- 84.60–1082.43 kW
- Fans
- ⌀500, ⌀800 mm
- Max. working pressure
- 27 bar
Model nomenclature
How to read the model codes of this series, with an example.
-
A
Series KC-M = KC-MF = modular V-type condenser with bottom chassis (catalogue "KCM"); "KC-M" = single-module form written without Nx.KC-MF = KC-MF = modular V-type condenser with bottom chassis (catalogue "KCM"); "KC-M" = single-module form written without Nx.
-
B
Fin type (optional "t") — = absent: standard corrugated finst = t: louvered fins (high-efficiency fin surface)
-
C
Fan rows (optional "Nx") — Catalogue: "Fan Row no." (number before x/X). For KC-MF it counts the modules; total fans = modules x fans per module. — = absent: 1 fan row2x = 2 fan rows3x = 3 fan rows (modules)4x = 4 fan rows (modules)5x = 5 fan rows (modules)6x = 6 fan rows (modules)
-
D
Number of fans per row — Digit 1-9; total fans = fan rows x this digit.
-
E
Fan diameter — Two digits = diameter / 10 (91 = Ø910). 50 = Ø500 mm80 = Ø800 mm
-
G
Coil tube rows (2nd dimensional letter) B = 3 tube rowsC = 4 tube rowsD = 5 tube rows
-
H
Fin spacing — Catalogue fin-spacing code. 1 = 2.1 mm5 = 2.5 mm
-
I
Generation code — Catalogue: "Generation Code". B = generation B
-
J
Fan data (fan motor code) — Catalogue: "Fan Data". Two digits select the fan motor (supply, poles); the meaning is series-specific. 01 = three-phase 400 V 50 Hz, 6-pole AC fan (in this series)09 = single-phase 230 V 50 Hz, 4-pole AC fan (in this series)
| Model | Heat rejection [kW] i Nominal conditions (EN 327): air inlet 25 °C, condensing temperature 40 °C (ΔT 15 K), gas inlet superheat 26 K, no subcooling, relative humidity 50 % | Fans | Air flow [m³/h] | Variants |
|---|---|---|---|---|
| KC-MF-6x280GB1-B01 C | 832.72 kW | 12 × ⌀800 | 262,660 |
Variants (1) |
| KC-MF-5x280GD1-B01 C | 902.03 kW | 10 × ⌀800 | 201,597 |
Variants (1) |
| KC-MF-6x280GC1-B01 C | 981.16 kW | 12 × ⌀800 | 252,083 |
Variants (1) |
| KC-MF-6x280GD1-B01 C | 1082.43 kW | 12 × ⌀800 | 241,916 |