Dry cooler BC/BD-2X563BB5-B19 C

Dry cooler BC/BD-2X563BB5-B19 C
Illustrative photo

Producer: Karyer · Line: BC/BD (General)

Product code: BC/BD-2X563BB5-B19 C

Heat rejection i
272.10 kW
Air flow
118,096 m³/h
Fans
10 × ⌀630 mm

Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %

Data

Coil
Air flow 118,096 m³/h
External surface 583.6 m²
Inner volume 107.6 dm³
Fin materialAluminium
Net weight 762 kg
Fans
Quantity 10
Diameter 630 mm
Speed 1,330 rpm
Power 12,500 W
Supply 400V/3Ph/50Hz
Motor type AC
Poles 4
Acoustic
Sound pressure 62.0 dB(A)
Sound power 94.0 dB(A)
Energy class E
Connections
Inlet 4"
Outlet 4"
Defrost
BC/BD-2X563BB5-B19 C None

Performance

Outlet 35 °C

Fluid inlet 35–60 °C (outlet = inlet − 5 K, at least 5 K above the air inlet); air inlet 25…50 °C.

WATER 40 → 35 °C, air inlet 25 °C

Heat rejection · High speed (Δ)
272.098 kW Fluid flow 47.22 m³/h Pressure drop 62.0 kPa
Heat rejection · Low speed (Y)
233.846 kW Fluid flow 40.59 m³/h Pressure drop 47.4 kPa

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)

WATER; rows: fluid inlet [°C], outlet = inlet − 5 K; columns: air inlet temperature. The highlighted cell is the nominal point. "—": not rated by the manufacturer.

High speed (Δ)

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)
Fluid inlet [°C] \ air [°C] 253035404550
35 154.65 not rated not rated not rated not rated not rated
40 272.10 155.51 not rated not rated not rated not rated
45 387.31 272.37 156.23 not rated not rated not rated
50 501.80 387.05 272.60 156.89 not rated not rated
55 615.97 501.06 386.86 272.87 157.53 not rated
60 729.98 614.78 500.45 386.79 273.23 158.18

Low speed (Y)

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)
Fluid inlet [°C] \ air [°C] 253035404550
35 133.46 not rated not rated not rated not rated not rated
40 233.85 134.19 not rated not rated not rated not rated
45 332.14 234.05 134.83 not rated not rated not rated
50 429.78 331.89 234.24 135.41 not rated not rated
55 527.11 429.11 331.71 234.49 136.00 not rated
60 624.28 526.04 428.59 331.67 234.82 136.60

Nominal rating

Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %

Fan connection Heat rejection [kW] Fluid flow [m³/h] Pressure drop [kPa]
High speed (Δ) 272.098 47.22 62.0
Low speed (Y) 233.846 40.59 47.4

Dimensions

Dimension drawing of BC/BD-2X563BB5-B19 C
Dimension drawing
Dimensions as drawn
A 4950 mm
B 1220 mm
C 2310 mm
F 1050 mm
G 450 mm
E 4600 mm
H 900 mm
I 2260 mm
K 5300 mm
D IN 4"
D OUT 4"
Overall [mm]
Length 4950 mm
Width 2310 mm
Height 1220 mm

Downloads