Dry cooler BC/BD-380HB5-B01 C

Dry cooler BC/BD-380HB5-B01 C
Illustrative photo

Producer: Karyer · Line: BC/BD (General)

Product code: BC/BD-380HB5-B01 C

Heat rejection i
107.05 kW
Air flow
51,997 m³/h
Fans
3 × ⌀800 mm

Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %

Data

Coil
Air flow 51,997 m³/h
External surface 206.9 m²
Inner volume 36.5 dm³
Fin materialAluminium
Net weight 444 kg
Fans
Quantity 3
Diameter 800 mm
Speed 900 rpm
Power 5,400 W
Supply 400V/3Ph/50Hz
Motor type AC
Poles 6
Acoustic
Sound pressure 54.0 dB(A)
Sound power 86.0 dB(A)
Energy class E
Connections
Inlet 3"
Outlet 3"
Defrost
BC/BD-380HB5-B01 C None

Performance

Outlet 35 °C

Fluid inlet 35–60 °C (outlet = inlet − 5 K, at least 5 K above the air inlet); air inlet 25…50 °C.

WATER 40 → 35 °C, air inlet 25 °C

Heat rejection · High speed (Δ)
107.052 kW Fluid flow 18.58 m³/h Pressure drop 28.7 kPa
Heat rejection · Low speed (Y)
86.975 kW Fluid flow 15.09 m³/h Pressure drop 19.8 kPa

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)

WATER; rows: fluid inlet [°C], outlet = inlet − 5 K; columns: air inlet temperature. The highlighted cell is the nominal point. "—": not rated by the manufacturer.

High speed (Δ)

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)
Fluid inlet [°C] \ air [°C] 253035404550
35 59.01 not rated not rated not rated not rated not rated
40 107.05 59.70 not rated not rated not rated not rated
45 154.11 107.53 60.30 not rated not rated not rated
50 200.89 154.45 107.98 60.84 not rated not rated
55 247.53 201.10 154.79 108.42 61.35 not rated
60 294.10 247.63 201.35 155.16 108.87 61.84

Low speed (Y)

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)
Fluid inlet [°C] \ air [°C] 253035404550
35 48.18 not rated not rated not rated not rated not rated
40 86.98 48.75 not rated not rated not rated not rated
45 124.84 87.33 49.24 not rated not rated not rated
50 162.42 125.06 87.67 49.68 not rated not rated
55 199.89 162.52 125.29 88.00 50.10 not rated
60 237.29 199.88 162.66 125.55 88.35 50.50

Nominal rating

Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %

Fan connection Heat rejection [kW] Fluid flow [m³/h] Pressure drop [kPa]
High speed (Δ) 107.052 18.58 28.7
Low speed (Y) 86.975 15.09 19.8

Dimensions

Dimension drawing of BC/BD-380HB5-B01 C
Dimension drawing
Dimensions as drawn
A 3500 mm
B 1450 mm
C 1230 mm
F 1150 mm
G 550 mm
E 3250 mm
H 1050 mm
I 1180 mm
K 3800 mm
D IN 3"
D OUT 3"
Overall [mm]
Length 3500 mm
Width 1230 mm
Height 1450 mm

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.