Dry cooler BC/BD-t-2X463AC5-B19 C

Dry cooler BC/BD-t-2X463AC5-B19 C
Illustrative photo

Producer: Karyer · Line: BC/BD (General)

Product code: BC/BD-t-2X463AC5-B19 C

Heat rejection i
313.47 kW
Air flow
88,277 m³/h
Fans
8 × ⌀630 mm

Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %

Data

Coil
Air flow 88,277 m³/h
External surface 622.5 m²
Inner volume 112.0 dm³
Fin materialAluminium
Net weight 669 kg
Fans
Quantity 8
Diameter 630 mm
Speed 1,330 rpm
Power 10,000 W
Supply 400V/3Ph/50Hz
Motor type AC
Poles 4
Acoustic
Sound pressure 60.0 dB(A)
Sound power 92.0 dB(A)
Energy class E
Connections
Inlet 4"
Outlet 4"
Defrost
BC/BD-t-2X463AC5-B19 C None

Performance

Outlet 35 °C

Fluid inlet 35–60 °C (outlet = inlet − 5 K, at least 5 K above the air inlet); air inlet 25…50 °C.

WATER 40 → 35 °C, air inlet 25 °C

Heat rejection · High speed (Δ)
313.467 kW Fluid flow 54.41 m³/h Pressure drop 97.0 kPa above the recommended pressure drop
Heat rejection · Low speed (Y)
260.562 kW Fluid flow 45.19 m³/h Pressure drop 69.8 kPa

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)

WATER; rows: fluid inlet [°C], outlet = inlet − 5 K; columns: air inlet temperature. The highlighted cell is the nominal point. "—": not rated by the manufacturer.

High speed (Δ)

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)
Fluid inlet [°C] \ air [°C] 253035404550
35 184.89 not rated not rated not rated not rated not rated
40 313.47 185.21 not rated not rated not rated not rated
45 438.69 312.86 185.52 not rated not rated not rated
50 562.85 437.25 312.38 185.84 not rated not rated
55 686.52 560.63 436.07 312.05 186.25 not rated
60 809.89 683.50 558.76 435.24 312.05 186.82

Low speed (Y)

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)
Fluid inlet [°C] \ air [°C] 253035404550
35 154.93 not rated not rated not rated not rated not rated
40 260.56 155.19 not rated not rated not rated not rated
45 363.28 260.02 155.42 not rated not rated not rated
50 465.02 362.04 259.59 155.70 not rated not rated
55 566.31 463.11 361.03 259.36 156.06 not rated
60 667.33 563.74 461.54 360.35 259.39 156.59

Nominal rating

Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %

Fan connection Heat rejection [kW] Fluid flow [m³/h] Pressure drop [kPa]
High speed (Δ) 313.467 54.41 97.0
Low speed (Y) 260.562 45.19 69.8

Dimensions

Dimension drawing of BC/BD-t-2X463AC5-B19 C
Dimension drawing
Dimensions as drawn
A 4050 mm
B 1220 mm
C 2310 mm
F 1050 mm
G 450 mm
E 3700 mm
H 900 mm
I 2260 mm
K 4400 mm
D IN 4"
D OUT 4"
Overall [mm]
Length 4050 mm
Width 2310 mm
Height 1220 mm

Downloads