Skip to Content

Dry cooler BE-291BC1-B04 C

Dry cooler BE-291BC1-B04 C
Illustrative photo

Producer: Karyer · Line: BE (Dry)

Product code: BE-291BC1-B04 C

Heat rejection i
182.72 kW
Air flow
55,016 m³/h
Fans
2 × ⌀910 mm

Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %

Data

Coil
Air flow 55,016 m³/h
External surface 564.1 m²
Inner volume 69.4 dm³
Fin materialAluminium
Net weight 608 kg
Fans
Quantity 2
Diameter 910 mm
Speed 840 rpm
Power 5,600 W
Supply 400V/3Ph/50Hz
Motor type AC
Poles 6
Acoustic
Sound pressure 61.0 dB(A)
Sound power 93.0 dB(A)
Energy class E
Connections
Inlet 2"
Outlet 2"
Defrost
BE-291BC1-B04 C None

Performance

Outlet 35 °C

Fluid inlet 35–60 °C (outlet = inlet − 5 K, at least 5 K above the air inlet); air inlet 25…50 °C.

WATER 40 → 35 °C, air inlet 25 °C

Heat rejection · High speed (Δ)
182.722 kW Fluid flow 31.71 m³/h Pressure drop 58.6 kPa
Heat rejection · Low speed (Y)
144.703 kW Fluid flow 25.11 m³/h Pressure drop 38.6 kPa

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)

WATER; rows: fluid inlet [°C], outlet = inlet − 5 K; columns: air inlet temperature. The highlighted cell is the nominal point. "—": not rated by the manufacturer.

High speed (Δ)

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)
Fluid inlet [°C] \ air [°C] 253035404550
35 106.63 not rated not rated not rated not rated not rated
40 182.72 106.91 not rated not rated not rated not rated
45 256.86 182.41 107.15 not rated not rated not rated
50 330.35 256.02 182.14 107.38 not rated not rated
55 403.55 329.02 255.31 181.95 107.63 not rated
60 476.56 401.71 327.85 254.76 181.91 107.94

Low speed (Y)

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)
Fluid inlet [°C] \ air [°C] 253035404550
35 85.10 not rated not rated not rated not rated not rated
40 144.70 85.32 not rated not rated not rated not rated
45 202.57 144.41 85.50 not rated not rated not rated
50 259.90 201.85 144.17 85.68 not rated not rated
55 316.98 258.78 201.25 144.00 85.90 not rated
60 373.91 315.46 257.83 200.80 143.96 86.17

Nominal rating

Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %

Fan connection Heat rejection [kW] Fluid flow [m³/h] Pressure drop [kPa]
High speed (Δ) 182.722 31.71 58.6
Low speed (Y) 144.703 25.11 38.6

Dimensions

Dimension drawing of BE-291BC1-B04 C
Dimension drawing
Dimensions as drawn
A 1958 mm
B 1210 mm
C 2860 mm
F 1050 mm
G 3460 mm
E1 1230 mm
D IN 2"
D OUT 2"
Overall [mm]
Length 3460 mm
Width 1210 mm
Height 1958 mm

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.