BE-2x980EB5-B01T C
1187.19 kW
Defrost: None
Product code: BE-2x791EB1-B04T C
Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %
How to read the code of this model.
| Air flow | 377,947 m³/h |
|---|---|
| External surface | 3,339.8 m² |
| Inner volume | 702.7 dm³ |
| Fin material | Aluminium |
| Net weight | 4,303 kg |
| Quantity | 14 |
|---|---|
| Diameter | 910 mm |
| Speed | 840 rpm |
| Power | 39,200 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 6 |
| Sound pressure | 69.0 dB(A) |
|---|---|
| Sound power | 102.0 dB(A) |
| Energy class | E |
| Inlet | 5" |
|---|---|
| Outlet | 5" |
| BE-2x791EB1-B04T C | None |
|---|
Fluid inlet 35–60 °C (outlet = inlet − 5 K, at least 5 K above the air inlet); air inlet 25…50 °C.
WATER 40 → 35 °C, air inlet 25 °C
WATER; rows: fluid inlet [°C], outlet = inlet − 5 K; columns: air inlet temperature. The highlighted cell is the nominal point. "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| Fluid inlet [°C] \ air [°C] | 25 | 30 | 35 | 40 | 45 | 50 |
|---|---|---|---|---|---|---|
| 35 | 688.27 | not rated | not rated | not rated | not rated | not rated |
| 40 | 1187.08 | 690.45 | not rated | not rated | not rated | not rated |
| 45 | 1674.43 | 1185.93 | 692.21 | not rated | not rated | not rated |
| 50 | 2158.01 | 1670.31 | 1184.88 | 693.91 | not rated | not rated |
| 55 | 2639.91 | 2151.08 | 1666.67 | 1184.33 | 695.78 | not rated |
| 60 | 3120.76 | 2630.12 | 2144.94 | 1664.09 | 1184.57 | 698.10 |
| Fluid inlet [°C] \ air [°C] | 25 | 30 | 35 | 40 | 45 | 50 |
|---|---|---|---|---|---|---|
| 35 | 552.35 | not rated | not rated | not rated | not rated | not rated |
| 40 | 944.23 | 554.01 | not rated | not rated | not rated | not rated |
| 45 | 1326.10 | 943.13 | 555.45 | not rated | not rated | not rated |
| 50 | 1704.56 | 1322.61 | 942.36 | 556.91 | not rated | not rated |
| 55 | 2081.61 | 1698.80 | 1319.69 | 942.05 | 558.62 | not rated |
| 60 | 2457.76 | 2073.57 | 1694.04 | 1317.86 | 942.58 | 560.68 |
Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %
| Fan connection | Heat rejection [kW] | Fluid flow [m³/h] | Pressure drop [kPa] |
|---|---|---|---|
| High speed (Δ) | 1187.077 | 206.05 | 59.1 |
| Low speed (Y) | 944.228 | 163.88 | 39.3 |
| A | 2880 mm |
|---|---|
| B | 2400 mm |
| C | 8850 mm |
| F | 2330 mm |
| G | 9450 mm |
| E1 | 1250 mm |
| E2 | 1200 mm |
| E3 | 3600 mm |
| H | 9100 mm |
| D IN | 5" |
| D OUT | 5" |
| Length | 9450 mm |
|---|---|
| Width | 2400 mm |
| Height | 2880 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.