BE-t-2x380GC5-B01T C
476.22 kW
Defrost: None
Product code: BE-591EC5-B04 C
Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %
| Air flow | 135,243 m³/h |
|---|---|
| External surface | 1,514.1 m² |
| Inner volume | 339.5 dm³ |
| Fin material | Aluminium |
| Net weight | 1,549 kg |
| Quantity | 5 |
|---|---|
| Diameter | 910 mm |
| Speed | 840 rpm |
| Power | 14,000 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 6 |
| Sound pressure | 65.0 dB(A) |
|---|---|
| Sound power | 97.0 dB(A) |
| Energy class | E |
| Inlet | 3" |
|---|---|
| Outlet | 3" |
| BE-591EC5-B04 C | None |
|---|
Fluid inlet 35–60 °C (outlet = inlet − 5 K, at least 5 K above the air inlet); air inlet 25…50 °C.
WATER 40 → 35 °C, air inlet 25 °C
WATER; rows: fluid inlet [°C], outlet = inlet − 5 K; columns: air inlet temperature. The highlighted cell is the nominal point. "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| Fluid inlet [°C] \ air [°C] | 25 | 30 | 35 | 40 | 45 | 50 |
|---|---|---|---|---|---|---|
| 35 | 283.20 | not rated | not rated | not rated | not rated | not rated |
| 40 | 476.11 | 283.20 | not rated | not rated | not rated | not rated |
| 45 | 664.42 | 474.70 | 283.16 | not rated | not rated | not rated |
| 50 | 851.15 | 661.68 | 473.50 | 283.22 | not rated | not rated |
| 55 | 1037.23 | 847.22 | 659.37 | 472.61 | 283.44 | not rated |
| 60 | 1222.95 | 1032.10 | 843.85 | 657.60 | 472.09 | 283.93 |
| Fluid inlet [°C] \ air [°C] | 25 | 30 | 35 | 40 | 45 | 50 |
|---|---|---|---|---|---|---|
| 35 | 224.38 | not rated | not rated | not rated | not rated | not rated |
| 40 | 373.73 | 224.35 | not rated | not rated | not rated | not rated |
| 45 | 519.28 | 372.61 | 224.35 | not rated | not rated | not rated |
| 50 | 663.54 | 517.15 | 371.68 | 224.44 | not rated | not rated |
| 55 | 807.22 | 660.47 | 515.40 | 371.07 | 224.68 | not rated |
| 60 | 950.56 | 803.20 | 657.90 | 514.12 | 370.83 | 225.12 |
Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %
| Fan connection | Heat rejection [kW] | Fluid flow [m³/h] | Pressure drop [kPa] |
|---|---|---|---|
| High speed (Δ) | 476.109 | 82.64 | 89.9 |
| Low speed (Y) | 373.725 | 64.81 | 58.4 |
| A | 1958 mm |
|---|---|
| B | 1210 mm |
| C | 6460 mm |
| F | 1050 mm |
| G | 7060 mm |
| E1 | 1230 mm |
| E2 | 1200 mm |
| D IN | 3" |
| D OUT | 3" |
| Length | 7060 mm |
|---|---|
| Width | 1210 mm |
| Height | 1958 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.