Dry cooler BE-t-2x380HB5-B01T C

Dry cooler BE-t-2x380HB5-B01T C
Illustrative photo

Producer: Karyer · Line: BE (Dry)

Product code: BE-t-2x380HB5-B01T C

Heat rejection i
495.56 kW
Air flow
132,623 m³/h
Fans
6 × ⌀800 mm

Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %

Data

Coil
Air flow 132,623 m³/h
External surface 1,477.4 m²
Inner volume 222.9 dm³
Fin materialAluminium
Net weight 2,083 kg
Fans
Quantity 6
Diameter 800 mm
Speed 900 rpm
Power 10,800 W
Supply 400V/3Ph/50Hz
Motor type AC
Poles 6
Acoustic
Sound pressure 55.0 dB(A)
Sound power 88.0 dB(A)
Energy class D
Connections
Inlet 3"
Outlet 3"
Defrost
BE-t-2x380HB5-B01T C None

Performance

Outlet 35 °C

Fluid inlet 35–60 °C (outlet = inlet − 5 K, at least 5 K above the air inlet); air inlet 25…50 °C.

WATER 40 → 35 °C, air inlet 25 °C

Heat rejection · High speed (Δ)
495.557 kW Fluid flow 85.94 m³/h Pressure drop 54.8 kPa
Heat rejection · Low speed (Y)
388.391 kW Fluid flow 67.36 m³/h Pressure drop 35.4 kPa

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)

WATER; rows: fluid inlet [°C], outlet = inlet − 5 K; columns: air inlet temperature. The highlighted cell is the nominal point. "—": not rated by the manufacturer.

High speed (Δ)

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)
Fluid inlet [°C] \ air [°C] 253035404550
35 294.33 not rated not rated not rated not rated not rated
40 495.56 294.28 not rated not rated not rated not rated
45 691.21 493.54 294.20 not rated not rated not rated
50 884.98 687.43 491.75 294.14 not rated not rated
55 1077.90 879.52 684.11 490.28 294.24 not rated
60 1270.33 1070.81 874.74 681.37 489.30 294.60

Low speed (Y)

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)
Fluid inlet [°C] \ air [°C] 253035404550
35 232.75 not rated not rated not rated not rated not rated
40 388.39 232.61 not rated not rated not rated not rated
45 539.23 386.55 232.35 not rated not rated not rated
50 688.50 535.92 384.91 232.24 not rated not rated
55 837.03 683.79 533.01 383.58 232.25 not rated
60 985.16 830.96 679.66 530.63 382.67 232.50

Nominal rating

Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %

Fan connection Heat rejection [kW] Fluid flow [m³/h] Pressure drop [kPa]
High speed (Δ) 495.557 85.94 54.8
Low speed (Y) 388.391 67.36 35.4

Dimensions

Dimension drawing of BE-t-2x380HB5-B01T C
Dimension drawing
Dimensions as drawn
A 2750 mm
B 2400 mm
C 5850 mm
F 2330 mm
G 6450 mm
E1 1850 mm
E2 1800 mm
H 6100 mm
D IN 3"
D OUT 3"
Overall [mm]
Length 6450 mm
Width 2400 mm
Height 2750 mm

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.