- Catalogue
- Dry coolers
- BE (Dry)
BE (Dry)
- Refrigerants
- ETHYLENE GLYCOL 30%, PROPYLENE GLYCOL 30%, WATER
- Capacity
- 69.30–1727.54 kW
- Fans
- ⌀800, ⌀910 mm
- Max. working pressure
- 10 bar
Model nomenclature
How to read the model codes of this series, with an example.
-
A
Series BE = BE = V-type dry cooler.
-
B
Fin type (optional "t") — = absent: standard corrugated finst = t: louvered fins (high-efficiency fin surface)
-
C
Fan rows (optional "Nx") — Catalogue: "Fan Row no." (number before x/X). — = absent: 1 fan row2x = 2 fan rows
-
D
Number of fans per row — Digit 1-9; total fans = fan rows x this digit.
-
E
Fan diameter — Two digits = diameter / 10 (91 = Ø910). 80 = Ø800 mm91 = Ø910 mm
-
G
Coil tube rows (2nd dimensional letter) B = 3 tube rowsC = 4 tube rowsD = 5 tube rows
-
H
Fin spacing — Catalogue fin-spacing code. 1 = 2.1 mm5 = 2.5 mm
-
I
Generation code — Catalogue: "Generation Code". B = generation BC = generation C
-
J
Fan data (fan motor code) — Catalogue: "Fan Data". Two digits select the fan motor (supply, poles); the meaning is series-specific. 01 = three-phase 400 V 50 Hz, 6-pole AC fan (in this series)04 = three-phase 400 V 50 Hz, 6-pole AC fan (in this series)
-
K
Delivery version (optional) — = absent: standardC = C: container delivery versionT = T: truck delivery version
| Model | Heat rejection [kW] i Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 % | Fans | Air flow [m³/h] | Variants |
|---|---|---|---|---|
| BE-t-391GB5-B04 C | 267.36 kW | 3 × ⌀910 | 83,928 |
Variants (1)
|
| BE-480BC5-B01 C | 268.00 kW | 4 × ⌀800 | 84,304 |
Variants (1)
|
| BE-2X280AC5-B01C C | 269.01 kW | 4 × ⌀800 | 81,251 |
Variants (1) |
| BE-2x280BD5-B01C C | 269.49 kW | 4 × ⌀800 | 77,522 |
Variants (1) |
| BE-391AC5-B04 C | 271.66 kW | 3 × ⌀910 | 83,089 |
Variants (1)
|
| BE-2x280AB1-B01T C | 272.66 kW | 4 × ⌀800 | 85,014 |
Variants (1) |
| BE-2x280DB5-B01T C | 273.01 kW | 4 × ⌀800 | 89,166 |
Variants (1) |
| BE-t-2x280GB5-B01T C | 273.33 kW | 4 × ⌀800 | 83,698 |
Variants (1) |
| BE-t-380HB1-B01 C | 273.48 kW | 3 × ⌀800 | 66,424 |
Variants (1)
|
| BE-380FB1-B01 C | 274.12 kW | 3 × ⌀800 | 67,425 |
Variants (1)
|
| BE-t-2x280GB1-B01C C | 275.61 kW | 4 × ⌀800 | 79,866 |
Variants (1) |
| BE-391BC1-B04 C | 275.79 kW | 3 × ⌀910 | 82,524 |
Variants (1)
|
| BE-2x291BB5-B04T C | 276.69 kW | 4 × ⌀910 | 112,601 |
Variants (1) |
| BE-380DD1-B01 C | 277.34 kW | 3 × ⌀800 | 65,486 |
Variants (1)
|
| BE-380CC5-B01 C | 277.42 kW | 3 × ⌀800 | 67,510 |
Variants (1)
|
| BE-391DB1-B04 C | 278.54 kW | 3 × ⌀910 | 88,650 |
Variants (1)
|
| BE-2x280DB1-B01C C | 278.59 kW | 4 × ⌀800 | 87,673 |
Variants (1) |
| BE-2x291BB1-C04C C | 278.97 kW | 4 × ⌀910 | 107,629 |
Variants (1) |
| BE-2X280BC1-B01T C | 279.59 kW | 4 × ⌀800 | 82,096 |
Variants (1) |
| BE-391BD5-B04 C | 281.25 kW | 3 × ⌀910 | 81,525 |
Variants (1)
|
| BE-t-480GB5-B01 C | 283.34 kW | 4 × ⌀800 | 84,861 |
Variants (1)
|
| BE-380FC5-B01 C | 283.96 kW | 3 × ⌀800 | 67,059 |
Variants (1)
|
| BE-480AB1-B01 C | 284.87 kW | 4 × ⌀800 | 86,207 |
Variants (1)
|
| BE-2x280BD1-B01C C | 286.04 kW | 4 × ⌀800 | 76,011 |
Variants (1) |
| BE-2X280AC5-B01T C | 286.58 kW | 4 × ⌀800 | 83,598 |
Variants (1) |
| BE-491BB5-B04 C | 287.43 kW | 4 × ⌀910 | 114,010 |
Variants (1)
|
| BE-t-2x280GC5-B01C C | 288.12 kW | 4 × ⌀800 | 77,627 |
Variants (1) |
| BE-2X280AC1-B01C C | 288.25 kW | 4 × ⌀800 | 80,081 |
Variants (1) |
| BE-2x291AB1-C04C C | 288.31 kW | 4 × ⌀910 | 106,583 |
Variants (1) |
| BE-480BC1-B01 C | 289.04 kW | 4 × ⌀800 | 83,419 |
Variants (1)
|
| BE-t-380HC5-B01 C | 289.91 kW | 3 × ⌀800 | 65,880 |
Variants (1)
|
| BE-2x280BD5-B01T C | 290.22 kW | 4 × ⌀800 | 80,970 |
Variants (1) |
| BE-380CC1-B01 C | 291.40 kW | 3 × ⌀800 | 67,307 |
Variants (1)
|
| BE-t-391GB1-B04 C | 291.57 kW | 3 × ⌀910 | 83,111 |
Variants (1)
|
| BE-580BB5-B01 C | 291.74 kW | 5 × ⌀800 | 107,750 |
Variants (1)
|
| BE-391AC1-B04 C | 292.30 kW | 3 × ⌀910 | 82,202 |
Variants (1)
|
| BE-391DC5-B04 C | 294.83 kW | 3 × ⌀910 | 87,826 |
Variants (1)
|
| BE-2x280AD5-B01C C | 295.55 kW | 4 × ⌀800 | 78,688 |
Variants (1) |
| BE-2x291BC5-C04C C | 296.33 kW | 4 × ⌀910 | 104,989 |
Variants (1) |
| BE-380FC1-B01 C | 296.34 kW | 3 × ⌀800 | 66,811 |
Variants (1)
|
| BE-2x291AB5-B04T C | 296.71 kW | 4 × ⌀910 | 111,724 |
Variants (1) |
| BE-t-2x280GB1-B01T C | 296.93 kW | 4 × ⌀800 | 82,764 |
Variants (1) |
| BE-380CD5-B01 C | 296.93 kW | 3 × ⌀800 | 67,067 |
Variants (1)
|
| BE-391AD5-B04 C | 297.21 kW | 3 × ⌀910 | 81,182 |
Variants (1)
|
| BE-2x280DB1-B01T C | 297.84 kW | 4 × ⌀800 | 88,810 |
Variants (1) |
| BE-2x280DC5-B01C C | 298.25 kW | 4 × ⌀800 | 86,803 |
Variants (1) |
| BE-391BD1-B04 C | 300.07 kW | 3 × ⌀910 | 80,465 |
Variants (1)
|
| BE-480BD5-B01 C | 300.12 kW | 4 × ⌀800 | 82,389 |
Variants (1)
|
| BE-380FD5-B01 C | 301.52 kW | 3 × ⌀800 | 66,516 |
Variants (1)
|
| BE-391CB5-B04 C | 303.49 kW | 3 × ⌀910 | 90,475 |
Variants (1)
|
Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %
Downloads
- BE-t-391GB5-B04 C — product datasheet (PDF)
- BE-480BC5-B01 C — product datasheet (PDF)
- BE-2X280AC5-B01C C — product datasheet (PDF)
- BE-2x280BD5-B01C C — product datasheet (PDF)
- BE-391AC5-B04 C — product datasheet (PDF)
- BE-2x280AB1-B01T C — product datasheet (PDF)
- BE-2x280DB5-B01T C — product datasheet (PDF)
- BE-t-2x280GB5-B01T C — product datasheet (PDF)
- BE-t-380HB1-B01 C — product datasheet (PDF)
- BE-380FB1-B01 C — product datasheet (PDF)
- BE-t-2x280GB1-B01C C — product datasheet (PDF)
- BE-391BC1-B04 C — product datasheet (PDF)
- BE-2x291BB5-B04T C — product datasheet (PDF)
- BE-380DD1-B01 C — product datasheet (PDF)
- BE-380CC5-B01 C — product datasheet (PDF)
- BE-391DB1-B04 C — product datasheet (PDF)
- BE-2x280DB1-B01C C — product datasheet (PDF)
- BE-2x291BB1-C04C C — product datasheet (PDF)
- BE-2X280BC1-B01T C — product datasheet (PDF)
- BE-391BD5-B04 C — product datasheet (PDF)
- BE-t-480GB5-B01 C — product datasheet (PDF)
- BE-380FC5-B01 C — product datasheet (PDF)
- BE-480AB1-B01 C — product datasheet (PDF)
- BE-2x280BD1-B01C C — product datasheet (PDF)
- BE-2X280AC5-B01T C — product datasheet (PDF)
- BE-491BB5-B04 C — product datasheet (PDF)
- BE-t-2x280GC5-B01C C — product datasheet (PDF)
- BE-2X280AC1-B01C C — product datasheet (PDF)
- BE-2x291AB1-C04C C — product datasheet (PDF)
- BE-480BC1-B01 C — product datasheet (PDF)
- BE-t-380HC5-B01 C — product datasheet (PDF)
- BE-2x280BD5-B01T C — product datasheet (PDF)
- BE-380CC1-B01 C — product datasheet (PDF)
- BE-t-391GB1-B04 C — product datasheet (PDF)
- BE-580BB5-B01 C — product datasheet (PDF)
- BE-391AC1-B04 C — product datasheet (PDF)
- BE-391DC5-B04 C — product datasheet (PDF)
- BE-2x280AD5-B01C C — product datasheet (PDF)
- BE-2x291BC5-C04C C — product datasheet (PDF)
- BE-380FC1-B01 C — product datasheet (PDF)
- BE-2x291AB5-B04T C — product datasheet (PDF)
- BE-t-2x280GB1-B01T C — product datasheet (PDF)
- BE-380CD5-B01 C — product datasheet (PDF)
- BE-391AD5-B04 C — product datasheet (PDF)
- BE-2x280DB1-B01T C — product datasheet (PDF)
- BE-2x280DC5-B01C C — product datasheet (PDF)
- BE-391BD1-B04 C — product datasheet (PDF)
- BE-480BD5-B01 C — product datasheet (PDF)
- BE-380FD5-B01 C — product datasheet (PDF)
- BE-391CB5-B04 C — product datasheet (PDF)
Ask about product
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.