BHSR-6P-ZB95
127.00 kW
Defrost: None
Product code: BHSR-5P-ZB114
Nominal conditions: evaporating -10 °C, condensing 45 °C (dew points), superheat 10 K, subcooling 3 K; refrigerant R404A where rated.
| Application | Medium temperature (MT) |
|---|---|
| Compressors | 5 × scroll compressors |
| Liquid receiver | 150 l |
| Net weight | 930 kg |
| Max. current | 145.0 A |
|---|---|
| Starting current | 290.0 A |
| Suction | 3"1/8 |
|---|---|
| Liquid | 1"5/8 |
| Discharge | 2"1/8 |
| L / W / H | 790/538/1605 mm |
|---|---|
| Weight | 150 kg |
Evaporating temperature -50…5 °C, condensing temperature 20…55 °C (dew points); superheat 10 K, subcooling 3 K.
R404A, evaporating -10 °C, condensing 45 °C (dew points; superheat 10 K, subcooling 3 K)
Heat rejection = refrigerating capacity + absorbed power. COP = refrigerating capacity / absorbed power.
| Te [°C] | Tc [°C] | Refrigerating capacity [kW] | Absorbed power [kW] | COP | Current [A] |
|---|---|---|---|---|---|
| -10 | 40 | 139.10 | 56.40 | 2.47 | 114.0 |
| -10 | 45 | 125.60 | 63.00 | 1.99 | 122.6 |
R404A; rows: condensing temperature Tc [°C]; columns: evaporating temperature Te [°C]. The highlighted cell is the nominal point. "—": outside the compressors' operating envelope.
| Tc \ Te [°C] | -25 | -20 | -15 | -10 | -5 | 0 | 5 |
|---|---|---|---|---|---|---|---|
| 20 | 98.00 | 122.70 | 151.50 | 184.80 | 223.20 | 266.90 | not rated |
| 25 | 90.60 | 114.70 | 142.60 | 174.80 | 211.80 | 254.00 | 301.80 |
| 30 | 82.50 | 105.90 | 132.80 | 163.80 | 199.30 | 239.80 | 285.80 |
| 35 | 73.70 | 96.40 | 122.30 | 151.90 | 185.80 | 224.60 | 268.70 |
| 40 | 64.40 | 86.20 | 110.90 | 139.10 | 171.40 | 208.30 | 250.30 |
| 45 | 54.50 | 75.40 | 98.90 | 125.60 | 156.10 | 191.00 | 230.90 |
| 50 | not rated | 64.00 | 86.20 | 111.20 | 139.90 | 172.80 | 210.50 |
| 55 | not rated | not rated | 72.90 | 96.20 | 123.00 | 153.70 | 189.20 |
| Tc \ Te [°C] | -25 | -20 | -15 | -10 | -5 | 0 | 5 |
|---|---|---|---|---|---|---|---|
| 20 | 35.30 | 36.10 | 37.00 | 37.90 | 38.70 | 39.40 | not rated |
| 25 | 39.40 | 40.00 | 40.80 | 41.70 | 42.60 | 43.40 | 44.00 |
| 30 | 44.20 | 44.50 | 45.10 | 45.90 | 46.80 | 47.60 | 48.40 |
| 35 | 50.00 | 49.90 | 50.20 | 50.80 | 51.50 | 52.30 | 53.10 |
| 40 | 56.90 | 56.30 | 56.20 | 56.40 | 56.90 | 57.50 | 58.30 |
| 45 | 65.10 | 63.90 | 63.30 | 63.00 | 63.20 | 63.50 | 64.10 |
| 50 | not rated | 72.90 | 71.60 | 70.80 | 70.50 | 70.50 | 70.80 |
| 55 | not rated | not rated | 81.40 | 79.90 | 79.00 | 78.50 | 78.40 |
| Tc \ Te [°C] | -25 | -20 | -15 | -10 | -5 | 0 | 5 |
|---|---|---|---|---|---|---|---|
| 20 | 2.78 | 3.40 | 4.09 | 4.88 | 5.77 | 6.77 | not rated |
| 25 | 2.30 | 2.87 | 3.50 | 4.19 | 4.97 | 5.85 | 6.86 |
| 30 | 1.87 | 2.38 | 2.94 | 3.57 | 4.26 | 5.04 | 5.90 |
| 35 | 1.47 | 1.93 | 2.44 | 2.99 | 3.61 | 4.29 | 5.06 |
| 40 | 1.13 | 1.53 | 1.97 | 2.47 | 3.01 | 3.62 | 4.29 |
| 45 | 0.84 | 1.18 | 1.56 | 1.99 | 2.47 | 3.01 | 3.60 |
| 50 | not rated | 0.88 | 1.20 | 1.57 | 1.98 | 2.45 | 2.97 |
| 55 | not rated | not rated | 0.90 | 1.20 | 1.56 | 1.96 | 2.41 |
| Length | 3115 mm |
|---|---|
| Width | 1000 mm |
| Height | 1500 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.