EA-DA-x-135BE7-B21 C
3.00 kW
Defrost: None
Product code: EA-DA-135BE7-C21 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 2,041 m³/h |
|---|---|
| Air throw | 11 m |
| External surface | 12.7 m² |
| Inner volume | 4.7 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 49 kg |
| Quantity | 1 |
|---|---|
| Diameter | 350 mm |
| Speed | 1,340 rpm |
| Power | 165 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 48.0 dB(A) |
|---|---|
| Sound power | 70.0 dB(A) |
| Energy class | C |
| Inlet | Ø9,52 |
|---|---|
| Outlet | Ø15,9 |
| EA-DA-135BE7-C21 C | None |
|---|---|
| EA-DA-135BE7-C21 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 1.42 | 1.47 | 1.51 | 1.54 | 1.54 | 1.53 | 1.51 | 1.54 | 1.64 | 1.77 | 1.72 | 1.70 | 1.68 | 1.65 |
| 5 | 1.76 | 1.86 | 1.94 | 2.00 | 2.03 | 2.03 | 2.01 | 2.04 | 2.16 | 2.34 | 2.26 | 2.23 | 2.19 | 2.13 |
| 6 | 2.09 | 2.24 | 2.36 | 2.45 | 2.52 | 2.54 | 2.53 | 2.56 | 2.71 | 2.93 | 2.83 | 2.79 | 2.73 | 2.63 |
| 7 | 2.37 | 2.57 | 2.76 | 2.91 | 3.01 | 3.06 | 3.07 | 3.09 | 3.28 | 3.55 | 3.42 | 3.37 | 3.30 | 3.17 |
| 8 | ≈ 2.62 | 2.87 | 3.10 | 3.30 | 3.41 | 3.49 | 3.54 | 3.59 | 3.81 | 4.14 | 4.03 | 3.97 | 3.88 | 3.72 |
| 9 | ≈ 2.83 | 3.13 | 3.42 | 3.63 | 3.81 | 3.93 | 3.99 | 4.06 | 4.32 | 4.69 | 4.57 | 4.51 | 4.42 | 4.26 |
| 10 | ≈ 2.52 | ≈ 3.37 | 3.67 | 3.97 | 4.19 | 4.35 | 4.44 | 4.53 | 4.81 | 5.23 | 5.11 | 5.04 | 4.94 | 4.76 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 5.107 |
| SC2 | 0 | 8 | 3.591 |
| SC3 | -18 | 7 | 2.953 |
| SC4 | -25 | 6 | 2.363 |
| SC5 | -34 | 6 | 2.126 |
| A | 957 mm |
|---|---|
| B | 730 mm |
| C | 530 mm |
| F | 560 mm |
| E | 535 mm |
| D IN | 1 x Ø9,52 |
| D OUT | 1 x Ø15,9 |
| Length | 957 mm |
|---|---|
| Width | 730 mm |
| Height | 530 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.