EA-DI-363GE7-A13 C
81.03 kW
Defrost: None
Product code: EA-DI-291GG7-A04 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 45,934 m³/h |
|---|---|
| External surface | 351.5 m² |
| Inner volume | 105.1 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 627 kg |
| Quantity | 2 |
|---|---|
| Diameter | 910 mm |
| Speed | 840 rpm |
| Power | 5,600 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 6 |
| Sound pressure | 71.0 dB(A) |
|---|---|
| Sound power | 94.5 dB(A) |
| Energy class | D |
| Inlet | Ø42 |
|---|---|
| Outlet | Ø66,7 |
| EA-DI-291GG7-A04 C | None |
|---|
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 34.08 | 34.36 | 34.53 | 34.78 | 34.72 | 34.44 | 34.01 | 34.68 | 36.89 | 39.92 | 38.92 | 38.53 | 37.96 | 37.10 |
| 5 | 42.90 | 44.00 | 44.93 | 45.66 | 45.88 | 45.70 | 45.18 | 45.79 | 48.59 | 52.46 | 50.96 | 50.44 | 49.71 | 48.65 |
| 6 | 51.11 | 52.93 | 54.76 | 56.26 | 57.01 | 57.17 | 56.83 | 57.42 | 60.88 | 65.82 | 63.78 | 63.01 | 61.87 | 60.11 |
| 7 | 58.06 | 61.06 | 63.78 | 66.13 | 67.63 | 68.42 | 68.62 | 69.49 | 73.67 | 79.74 | 77.30 | 76.33 | 74.89 | 72.53 |
| 8 | 64.37 | 68.45 | 72.14 | 75.32 | 77.45 | 78.66 | 79.13 | 80.14 | 85.09 | 92.37 | 89.99 | 89.02 | 87.54 | 85.04 |
| 9 | 70.14 | 75.36 | 80.12 | 84.25 | 87.11 | 88.80 | 89.59 | 90.82 | 96.45 | 104.69 | 102.09 | 100.95 | 99.23 | 96.20 |
| 10 | ≈ 75.36 | 81.76 | 87.68 | 92.87 | 96.47 | 98.83 | 100.02 | 101.53 | 107.85 | 117.08 | 114.30 | 113.02 | 111.04 | 107.53 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | not rated | not rated | not rated | not rated | not rated | not rated | not rated | 28.26 | 30.12 | 32.67 | 31.98 | 31.76 | 31.48 | 31.00 |
| 5 | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated |
| 6 | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated |
| 7 | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated |
| 8 | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated |
| 9 | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated |
| 10 | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 114.298 | — |
| SC2 | 0 | 8 | 80.137 | — |
| SC3 | -18 | 7 | 66.825 | — |
| SC4 | -25 | 6 | 54.755 | — |
| SC5 | -34 | 6 | 51.643 | — |
| A | 3025 mm |
|---|---|
| B | 1100 mm |
| C | 1350 mm |
| F | 1060 mm |
| G | 1900 mm |
| E1 | 1318 mm |
| E | 2635 mm |
| D IN | 1 x Ø42 |
| D OUT | 1 x Ø66,7 |
| Length | 3025 mm |
|---|---|
| Width | 1900 mm |
| Height | 1350 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.