EA-330AC4-C05 C
6.69 kW
Defrost: Electric
Product code: EA-145AC6-C01 C ED
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 5,248 m³/h |
|---|---|
| Air throw | 16 m |
| External surface | 19.2 m² |
| Inner volume | 5.8 dm³ |
| Fin spacing | 6.0 mm |
| Fin material | Aluminium |
| Net weight | 46 kg |
| Quantity | 1 |
|---|---|
| Diameter | 450 mm |
| Speed | 1,310 rpm |
| Power | 490 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 53.0 dB(A) |
|---|---|
| Sound power | 75.0 dB(A) |
| Energy class | D |
| Inlet | Ø15,9 |
|---|---|
| Outlet | Ø22 |
| EA-145AC6-C01 C | None |
|---|---|
| EA-145AC6-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 2.63 | 2.66 | 2.69 | 2.70 | 2.69 | 2.66 | 2.61 | 2.64 | 2.79 | 3.00 | 2.90 | 2.87 | 2.81 | 2.74 |
| 5 | 3.41 | 3.51 | 3.60 | 3.66 | 3.68 | 3.67 | 3.63 | 3.66 | 3.88 | 4.19 | 4.06 | 4.01 | 3.95 | 3.85 |
| 6 | 4.09 | 4.28 | 4.46 | 4.60 | 4.70 | 4.75 | 4.74 | 4.76 | 5.05 | 5.45 | 5.29 | 5.23 | 5.14 | 5.00 |
| 7 | 4.66 | 4.94 | 5.19 | 5.38 | 5.53 | 5.62 | 5.66 | 5.74 | 6.10 | 6.63 | 6.48 | 6.43 | 6.34 | 6.20 |
| 8 | 5.18 | 5.52 | 5.86 | 6.15 | 6.36 | 6.50 | 6.57 | 6.68 | 7.10 | 7.72 | 7.55 | 7.48 | 7.38 | 7.21 |
| 9 | 5.65 | 6.08 | 6.52 | 6.90 | 7.18 | 7.38 | 7.49 | 7.62 | 8.10 | 8.82 | 8.64 | 8.56 | 8.44 | 8.24 |
| 10 | ≈ 6.03 | 6.61 | 7.14 | 7.62 | 7.99 | 8.24 | 8.40 | 8.56 | 9.11 | 9.92 | 9.74 | 9.65 | 9.52 | 9.29 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 9.736 |
| SC2 | 0 | 8 | 6.676 |
| SC3 | -18 | 7 | 5.446 |
| SC4 | -25 | 6 | 4.455 |
| SC5 | -34 | 6 | 4.138 |
| A | 1067 mm |
|---|---|
| B | 590 mm |
| C | 645 mm |
| F | 395 mm |
| E | 735 mm |
| D IN | 1 x Ø15,9 |
| D OUT | 1 x Ø22 |
| Length | 1067 mm |
|---|---|
| Width | 590 mm |
| Height | 645 mm |
Our engineers answer with a selection for your conditions.