EA-330AC7-C05 C
5.83 kW
Defrost: Electric
Product code: EA-145AC8-C01 C ED
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 5,428 m³/h |
|---|---|
| Air throw | 16 m |
| External surface | 14.8 m² |
| Inner volume | 5.7 dm³ |
| Fin spacing | 8.0 mm |
| Fin material | Aluminium |
| Net weight | 45 kg |
| Quantity | 1 |
|---|---|
| Diameter | 450 mm |
| Speed | 1,310 rpm |
| Power | 490 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 53.0 dB(A) |
|---|---|
| Sound power | 75.0 dB(A) |
| Energy class | D |
| Inlet | Ø12,7 |
|---|---|
| Outlet | Ø22 |
| EA-145AC8-C01 C | None |
|---|---|
| EA-145AC8-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 2.28 | 2.27 | 2.26 | 2.25 | 2.23 | 2.19 | 2.15 | 2.15 | 2.26 | 2.43 | 2.34 | 2.31 | 2.27 | 2.20 |
| 5 | 2.97 | 3.02 | 3.07 | 3.10 | 3.09 | 3.06 | 3.02 | 3.03 | 3.20 | 3.44 | 3.32 | 3.28 | 3.22 | 3.13 |
| 6 | 3.65 | 3.78 | 3.88 | 3.97 | 4.00 | 4.00 | 3.97 | 3.99 | 4.22 | 4.55 | 4.39 | 4.33 | 4.25 | 4.13 |
| 7 | 4.23 | 4.43 | 4.61 | 4.77 | 4.87 | 4.93 | 4.94 | 4.98 | 5.28 | 5.70 | 5.53 | 5.46 | 5.36 | 5.20 |
| 8 | 4.73 | 5.01 | 5.27 | 5.46 | 5.61 | 5.70 | 5.75 | 5.83 | 6.19 | 6.73 | 6.58 | 6.52 | 6.43 | 6.28 |
| 9 | 5.20 | 5.53 | 5.85 | 6.15 | 6.35 | 6.49 | 6.57 | 6.66 | 7.09 | 7.70 | 7.54 | 7.47 | 7.37 | 7.20 |
| 10 | 5.61 | 6.03 | 6.45 | 6.81 | 7.08 | 7.27 | 7.39 | 7.50 | 7.98 | 8.69 | 8.52 | 8.44 | 8.33 | 8.13 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 8.516 |
| SC2 | 0 | 8 | 5.828 |
| SC3 | -18 | 7 | 4.814 |
| SC4 | -25 | 6 | 3.884 |
| SC5 | -34 | 6 | 3.680 |
| A | 1067 mm |
|---|---|
| B | 590 mm |
| C | 645 mm |
| F | 395 mm |
| E | 735 mm |
| D IN | 1 x Ø12,7 |
| D OUT | 1 x Ø22 |
| Length | 1067 mm |
|---|---|
| Width | 590 mm |
| Height | 645 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.