EA-630BC8-C05 C
9.46 kW
Defrost: None
Product code: EA-145AG7-C01 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 4,312 m³/h |
|---|---|
| Air throw | 14 m |
| External surface | 33.4 m² |
| Inner volume | 11.3 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 65 kg |
| Quantity | 1 |
|---|---|
| Diameter | 450 mm |
| Speed | 1,310 rpm |
| Power | 490 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 53.0 dB(A) |
|---|---|
| Sound power | 75.0 dB(A) |
| Energy class | D |
| Inlet | Ø12,7 |
|---|---|
| Outlet | Ø28 |
| EA-145AG7-C01 C | None |
|---|---|
| EA-145AG7-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 3.92 | 3.98 | 4.04 | 4.09 | 4.09 | 4.06 | 4.00 | 4.09 | 4.35 | 4.71 | 4.59 | 4.55 | 4.50 | 4.44 |
| 5 | 4.92 | 5.08 | 5.23 | 5.35 | 5.40 | 5.39 | 5.33 | 5.41 | 5.74 | 6.21 | 6.01 | 5.94 | 5.85 | 5.70 |
| 6 | 5.89 | 6.17 | 6.42 | 6.63 | 6.74 | 6.76 | 6.71 | 6.80 | 7.20 | 7.79 | 7.52 | 7.41 | 7.25 | 6.99 |
| 7 | 6.74 | 7.14 | 7.50 | 7.81 | 8.01 | 8.12 | 8.13 | 8.20 | 8.69 | 9.41 | 9.08 | 8.94 | 8.73 | 8.38 |
| 8 | 7.47 | 8.00 | 8.48 | 8.84 | 9.13 | 9.29 | 9.34 | 9.48 | 10.06 | 10.91 | 10.60 | 10.45 | 10.23 | 9.81 |
| 9 | 8.13 | 8.80 | 9.34 | 9.87 | 10.24 | 10.47 | 10.57 | 10.74 | 11.40 | 12.35 | 12.01 | 11.84 | 11.58 | 11.12 |
| 10 | ≈ 8.73 | 9.47 | 10.21 | 10.87 | 11.33 | 11.64 | 11.79 | 11.99 | 12.73 | 13.80 | 13.43 | 13.25 | 12.95 | 12.42 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 13.432 |
| SC2 | 0 | 8 | 9.482 |
| SC3 | -18 | 7 | 7.903 |
| SC4 | -25 | 6 | 6.420 |
| SC5 | -34 | 6 | 5.958 |
| A | 1067 mm |
|---|---|
| B | 690 mm |
| C | 645 mm |
| F | 495 mm |
| E | 735 mm |
| D IN | 1 x Ø12,7 |
| D OUT | 1 x Ø28 |
| Length | 1067 mm |
|---|---|
| Width | 690 mm |
| Height | 645 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.