EA-163FD7-C19 C
15.16 kW
Defrost: Electric
Product code: EA-163EE4-C01 C ED
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 7,448 m³/h |
|---|---|
| Air throw | 18 m |
| External surface | 100.2 m² |
| Inner volume | 20.4 dm³ |
| Fin spacing | 4.6 mm |
| Fin material | Aluminium |
| Net weight | 127 kg |
| Quantity | 1 |
|---|---|
| Diameter | 630 mm |
| Speed | 860 rpm |
| Power | 600 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 6 |
| Sound pressure | 53.0 dB(A) |
|---|---|
| Sound power | 75.0 dB(A) |
| Energy class | C |
| Inlet | Ø22 |
|---|---|
| Outlet | Ø35 |
| EA-163EE4-C01 C | None |
|---|---|
| EA-163EE4-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 6.52 | 6.55 | 6.62 | 6.69 | 6.71 | 6.69 | 6.64 | 6.78 | 7.21 | 7.82 | 7.66 | 7.61 | 7.53 | 7.44 |
| 5 | 8.14 | 8.34 | 8.52 | 8.66 | 8.72 | 8.70 | 8.64 | 8.76 | 9.30 | 10.07 | 9.81 | 9.72 | 9.59 | 9.39 |
| 6 | 9.68 | 10.06 | 10.39 | 10.61 | 10.75 | 10.79 | 10.74 | 10.84 | 11.50 | 12.45 | 12.08 | 11.94 | 11.74 | 11.43 |
| 7 | 11.10 | 11.62 | 12.13 | 12.56 | 12.82 | 12.93 | 12.91 | 13.02 | 13.80 | 14.94 | 14.49 | 14.31 | 14.05 | 13.62 |
| 8 | 12.27 | 13.02 | 13.71 | 14.29 | 14.69 | 14.91 | 14.99 | 15.17 | 16.10 | 17.47 | 16.99 | 16.77 | 16.45 | 15.91 |
| 9 | 13.37 | 14.33 | 15.21 | 15.97 | 16.50 | 16.80 | 16.94 | 17.15 | 18.21 | 19.75 | 19.26 | 19.04 | 18.71 | 18.15 |
| 10 | ≈ 14.36 | 15.55 | 16.64 | 17.60 | 18.26 | 18.68 | 18.89 | 19.15 | 20.33 | 22.05 | 21.52 | 21.27 | 20.90 | 20.24 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 21.520 |
| SC2 | 0 | 8 | 15.169 |
| SC3 | -18 | 7 | 12.685 |
| SC4 | -25 | 6 | 10.392 |
| SC5 | -34 | 6 | 9.776 |
| A | 1215 mm |
|---|---|
| B | 1000 mm |
| C | 1190 mm |
| F | 960 mm |
| E | 835 mm |
| D IN | 1 x Ø22 |
| D OUT | 1 x Ø35 |
| Length | 1215 mm |
|---|---|
| Width | 1000 mm |
| Height | 1190 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.