EA-263EC10-C01 C
17.10 kW
Defrost: None
Product code: EA-163EG4-C01 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 6,794 m³/h |
|---|---|
| Air throw | 17 m |
| External surface | 133.5 m² |
| Inner volume | 26.1 dm³ |
| Fin spacing | 4.6 mm |
| Fin material | Aluminium |
| Net weight | 148 kg |
| Quantity | 1 |
|---|---|
| Diameter | 630 mm |
| Speed | 860 rpm |
| Power | 600 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 6 |
| Sound pressure | 54.0 dB(A) |
|---|---|
| Sound power | 75.9 dB(A) |
| Energy class | C |
| Inlet | Ø22 |
|---|---|
| Outlet | Ø35 |
| EA-163EG4-C01 C | None |
|---|---|
| EA-163EG4-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 7.48 | 7.60 | 7.71 | 7.81 | 7.85 | 7.84 | 7.78 | 7.95 | 8.46 | 9.19 | 8.99 | 8.92 | 8.83 | 8.70 |
| 5 | 9.30 | 9.56 | 9.78 | 9.98 | 10.06 | 10.05 | 9.98 | 10.13 | 10.75 | 11.66 | 11.33 | 11.21 | 11.04 | 10.78 |
| 6 | 10.97 | 11.42 | 11.82 | 12.15 | 12.32 | 12.32 | 12.26 | 12.39 | 13.13 | 14.22 | 13.79 | 13.61 | 13.35 | 12.93 |
| 7 | 12.52 | 13.19 | 13.70 | 14.20 | 14.50 | 14.62 | 14.59 | 14.73 | 15.60 | 16.89 | 16.35 | 16.13 | 15.78 | 15.20 |
| 8 | 13.92 | 14.71 | 15.50 | 16.18 | 16.63 | 16.87 | 16.94 | 17.10 | 18.12 | 19.60 | 18.99 | 18.71 | 18.28 | 17.56 |
| 9 | 15.05 | 16.15 | 17.16 | 18.03 | 18.63 | 18.96 | 19.09 | 19.32 | 20.49 | 22.20 | 21.58 | 21.29 | 20.83 | 19.98 |
| 10 | ≈ 16.15 | 17.49 | 18.74 | 19.82 | 20.57 | 21.03 | 21.24 | 21.51 | 22.82 | 24.71 | 24.04 | 23.71 | 23.20 | 22.31 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 24.037 |
| SC2 | 0 | 8 | 17.102 |
| SC3 | -18 | 7 | 14.344 |
| SC4 | -25 | 6 | 11.818 |
| SC5 | -34 | 6 | 11.084 |
| A | 1215 mm |
|---|---|
| B | 1100 mm |
| C | 1190 mm |
| F | 1060 mm |
| E | 835 mm |
| D IN | 1 x Ø22 |
| D OUT | 1 x Ø35 |
| Length | 1215 mm |
|---|---|
| Width | 1100 mm |
| Height | 1190 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.