EA-140AE7-C01 C
5.45 kW
Defrost: Electric
Product code: EA-230BE4-C05 C ED
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 2,040 m³/h |
|---|---|
| Air throw | 6 m |
| External surface | 38.0 m² |
| Inner volume | 7.9 dm³ |
| Fin spacing | 4.2 mm |
| Fin material | Aluminium |
| Net weight | 40 kg |
| Quantity | 2 |
|---|---|
| Diameter | 300 mm |
| Speed | 1,300 rpm |
| Power | 240 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 43.0 dB(A) |
|---|---|
| Sound power | 65.0 dB(A) |
| Energy class | D |
| Inlet | Ø12,7 |
|---|---|
| Outlet | Ø22 |
| EA-230BE4-C05 C | None |
|---|---|
| EA-230BE4-C05 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 2.37 | 2.44 | 2.50 | 2.55 | 2.57 | 2.57 | 2.55 | 2.62 | 2.79 | 3.03 | 2.96 | 2.94 | 2.90 | 2.86 |
| 5 | 2.91 | 3.03 | 3.14 | 3.23 | 3.28 | 3.30 | 3.28 | 3.33 | 3.54 | 3.84 | 3.73 | 3.69 | 3.62 | 3.52 |
| 6 | 3.44 | 3.62 | 3.78 | 3.92 | 4.00 | 4.03 | 4.02 | 4.08 | 4.32 | 4.69 | 4.54 | 4.48 | 4.38 | 4.23 |
| 7 | 3.90 | 4.15 | 4.38 | 4.58 | 4.71 | 4.78 | 4.78 | 4.82 | 5.11 | 5.53 | 5.37 | 5.29 | 5.17 | 4.98 |
| 8 | 4.30 | 4.63 | 4.92 | 5.18 | 5.32 | 5.42 | 5.46 | 5.54 | 5.88 | 6.37 | 6.19 | 6.11 | 5.98 | 5.75 |
| 9 | ≈ 4.67 | 5.07 | 5.40 | 5.72 | 5.94 | 6.09 | 6.14 | 6.24 | 6.62 | 7.17 | 6.98 | 6.89 | 6.74 | 6.50 |
| 10 | ≈ 4.99 | 5.47 | 5.88 | 6.27 | 6.55 | 6.74 | 6.83 | 6.93 | 7.36 | 7.98 | 7.77 | 7.67 | 7.51 | 7.23 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 7.773 |
| SC2 | 0 | 8 | 5.539 |
| SC3 | -18 | 7 | 4.635 |
| SC4 | -25 | 6 | 3.782 |
| SC5 | -34 | 6 | 3.479 |
| A | 1357 mm |
|---|---|
| B | 567 mm |
| C | 445 mm |
| F | 395 mm |
| E1 | 517.5 mm |
| E | 1035 mm |
| D IN | 1 x Ø12,7 |
| D OUT | 1 x Ø22 |
| Length | 1357 mm |
|---|---|
| Width | 567 mm |
| Height | 445 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.