EA-150AE10-C09 C
9.61 kW
Defrost: Electric
Product code: EA-235AG6-C01 C ED
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 3,796 m³/h |
|---|---|
| Air throw | 9 m |
| External surface | 43.8 m² |
| Inner volume | 12.9 dm³ |
| Fin spacing | 6.0 mm |
| Fin material | Aluminium |
| Net weight | 70 kg |
| Quantity | 2 |
|---|---|
| Diameter | 350 mm |
| Speed | 1,340 rpm |
| Power | 330 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 51.0 dB(A) |
|---|---|
| Sound power | 73.0 dB(A) |
| Energy class | C |
| Inlet | Ø15,9 |
|---|---|
| Outlet | Ø28 |
| EA-235AG6-C01 C | None |
|---|---|
| EA-235AG6-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 4.19 | 4.21 | 4.23 | 4.26 | 4.26 | 4.23 | 4.17 | 4.28 | 4.56 | 4.94 | 4.83 | 4.79 | 4.74 | 4.67 |
| 5 | 5.26 | 5.35 | 5.44 | 5.52 | 5.54 | 5.51 | 5.44 | 5.53 | 5.87 | 6.36 | 6.16 | 6.08 | 5.98 | 5.83 |
| 6 | 6.32 | 6.47 | 6.64 | 6.79 | 6.85 | 6.85 | 6.77 | 6.85 | 7.25 | 7.84 | 7.57 | 7.46 | 7.30 | 7.03 |
| 7 | 7.29 | 7.58 | 7.85 | 8.07 | 8.18 | 8.20 | 8.13 | 8.20 | 8.68 | 9.38 | 9.05 | 8.90 | 8.69 | 8.33 |
| 8 | 8.18 | 8.58 | 8.95 | 9.27 | 9.47 | 9.55 | 9.51 | 9.58 | 10.14 | 10.93 | 10.56 | 10.39 | 10.13 | 9.68 |
| 9 | 8.96 | 9.49 | 9.98 | 10.39 | 10.61 | 10.75 | 10.77 | 10.88 | 11.53 | 12.47 | 12.09 | 11.90 | 11.59 | 11.05 |
| 10 | 9.68 | 10.35 | 10.90 | 11.42 | 11.77 | 11.96 | 12.01 | 12.15 | 12.87 | 13.92 | 13.51 | 13.32 | 13.00 | 12.43 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 13.512 |
| SC2 | 0 | 8 | 9.581 |
| SC3 | -18 | 7 | 8.126 |
| SC4 | -25 | 6 | 6.643 |
| SC5 | -34 | 6 | 6.369 |
| A | 1357 mm |
|---|---|
| B | 673 mm |
| C | 525 mm |
| F | 495 mm |
| E1 | 517.5 mm |
| E | 1035 mm |
| D IN | 1 x Ø15,9 |
| D OUT | 1 x Ø28 |
| Length | 1357 mm |
|---|---|
| Width | 623 mm |
| Height | 525 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.