EA-440AE10-C01 C
19.57 kW
Defrost: Electric
Product code: EA-245AG7-C01 C ED
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 8,625 m³/h |
|---|---|
| Air throw | 15 m |
| External surface | 66.8 m² |
| Inner volume | 22.8 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 112 kg |
| Quantity | 2 |
|---|---|
| Diameter | 450 mm |
| Speed | 1,310 rpm |
| Power | 980 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 56.0 dB(A) |
|---|---|
| Sound power | 78.0 dB(A) |
| Energy class | C |
| Inlet | Ø22 |
|---|---|
| Outlet | Ø42 |
| EA-245AG7-C01 C | None |
|---|---|
| EA-245AG7-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 8.45 | 8.40 | 8.38 | 8.38 | 8.32 | 8.22 | 8.08 | 8.25 | 8.77 | 9.49 | 9.25 | 9.18 | 9.08 | 8.92 |
| 5 | 10.79 | 10.88 | 10.97 | 11.06 | 11.04 | 10.94 | 10.76 | 10.90 | 11.56 | 12.49 | 12.08 | 11.94 | 11.75 | 11.47 |
| 6 | 13.12 | 13.37 | 13.57 | 13.79 | 13.85 | 13.79 | 13.60 | 13.71 | 14.52 | 15.67 | 15.10 | 14.87 | 14.55 | 14.03 |
| 7 | 15.26 | 15.74 | 16.18 | 16.54 | 16.72 | 16.70 | 16.53 | 16.64 | 17.59 | 18.99 | 18.26 | 17.96 | 17.51 | 16.78 |
| 8 | 17.18 | 17.87 | 18.52 | 19.08 | 19.43 | 19.56 | 19.49 | 19.59 | 20.71 | 22.35 | 21.52 | 21.15 | 20.60 | 19.67 |
| 9 | 18.91 | 19.86 | 20.73 | 21.39 | 21.85 | 22.10 | 22.11 | 22.33 | 23.65 | 25.57 | 24.77 | 24.40 | 23.76 | 22.63 |
| 10 | 20.52 | 21.75 | 22.74 | 23.71 | 24.32 | 24.67 | 24.75 | 25.01 | 26.48 | 28.62 | 27.75 | 27.32 | 26.67 | 25.50 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 27.745 |
| SC2 | 0 | 8 | 19.594 |
| SC3 | -18 | 7 | 16.634 |
| SC4 | -25 | 6 | 13.572 |
| SC5 | -34 | 6 | 13.189 |
| A | 1767 mm |
|---|---|
| B | 690 mm |
| C | 645 mm |
| F | 495 mm |
| E1 | 718 mm |
| E | 1435 mm |
| D IN | 1 x Ø22 |
| D OUT | 1 x Ø42 |
| Length | 1767 mm |
|---|---|
| Width | 690 mm |
| Height | 645 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.