EA-263FC7-C19 C
23.59 kW
Defrost: Electric
Product code: EA-263EC4-C01 C ED
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 16,671 m³/h |
|---|---|
| Air throw | 22 m |
| External surface | 133.7 m² |
| Inner volume | 27.5 dm³ |
| Fin spacing | 4.6 mm |
| Fin material | Aluminium |
| Net weight | 177 kg |
| Quantity | 2 |
|---|---|
| Diameter | 630 mm |
| Speed | 860 rpm |
| Power | 1,200 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 6 |
| Sound pressure | 55.0 dB(A) |
|---|---|
| Sound power | 77.1 dB(A) |
| Energy class | D |
| Inlet | Ø28 |
|---|---|
| Outlet | Ø42 |
| EA-263EC4-C01 C | None |
|---|---|
| EA-263EC4-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 10.02 | 9.94 | 9.91 | 9.92 | 9.88 | 9.81 | 9.73 | 9.87 | 10.47 | 11.33 | 11.07 | 10.98 | 10.84 | 10.64 |
| 5 | 12.91 | 12.95 | 13.01 | 13.08 | 13.04 | 12.96 | 12.84 | 12.95 | 13.73 | 14.85 | 14.47 | 14.34 | 14.16 | 13.89 |
| 6 | 15.69 | 15.96 | 16.20 | 16.40 | 16.45 | 16.35 | 16.21 | 16.30 | 17.26 | 18.65 | 18.12 | 17.93 | 17.66 | 17.25 |
| 7 | 18.32 | 18.80 | 19.30 | 19.71 | 19.89 | 19.91 | 19.80 | 19.88 | 21.05 | 22.73 | 22.05 | 21.79 | 21.41 | 20.83 |
| 8 | 20.47 | 21.28 | 22.02 | 22.67 | 23.08 | 23.30 | 23.36 | 23.57 | 25.01 | 27.03 | 26.22 | 25.90 | 25.43 | 24.68 |
| 9 | 22.53 | 23.65 | 24.66 | 25.54 | 26.10 | 26.42 | 26.55 | 26.79 | 28.42 | 30.83 | 30.07 | 29.76 | 29.30 | 28.55 |
| 10 | 24.43 | 25.90 | 27.21 | 28.35 | 29.11 | 29.55 | 29.76 | 30.04 | 31.88 | 34.58 | 33.74 | 33.39 | 32.86 | 31.97 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 33.744 |
| SC2 | 0 | 8 | 23.565 |
| SC3 | -18 | 7 | 19.803 |
| SC4 | -25 | 6 | 16.203 |
| SC5 | -34 | 6 | 15.769 |
| A | 2015 mm |
|---|---|
| B | 900 mm |
| C | 1190 mm |
| F | 860 mm |
| E1 | 818 mm |
| E | 1635 mm |
| D IN | 1 x Ø28 |
| D OUT | 1 x Ø42 |
| Length | 2015 mm |
|---|---|
| Width | 900 mm |
| Height | 1190 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.