EA-540AC8-C01 C
19.53 kW
Defrost: Electric
Product code: EA-263EC7-C01 C ED
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 17,525 m³/h |
|---|---|
| Air throw | 23 m |
| External surface | 90.1 m² |
| Inner volume | 27.5 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 168 kg |
| Quantity | 2 |
|---|---|
| Diameter | 630 mm |
| Speed | 860 rpm |
| Power | 1,200 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 6 |
| Sound pressure | 55.0 dB(A) |
|---|---|
| Sound power | 77.4 dB(A) |
| Energy class | D |
| Inlet | Ø28 |
|---|---|
| Outlet | Ø42 |
| EA-263EC7-C01 C | None |
|---|---|
| EA-263EC7-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 7.56 | 7.43 | 7.37 | 7.36 | 7.32 | 7.28 | 7.24 | 7.33 | 7.76 | 8.40 | 8.23 | 8.16 | 8.07 | 7.94 |
| 5 | 10.03 | 9.95 | 9.93 | 9.94 | 9.90 | 9.84 | 9.76 | 9.84 | 10.44 | 11.30 | 11.03 | 10.94 | 10.81 | 10.59 |
| 6 | 12.56 | 12.59 | 12.65 | 12.73 | 12.70 | 12.64 | 12.53 | 12.60 | 13.35 | 14.43 | 14.04 | 13.90 | 13.71 | 13.42 |
| 7 | 15.00 | 15.21 | 15.41 | 15.60 | 15.66 | 15.62 | 15.51 | 15.56 | 16.48 | 17.78 | 17.28 | 17.09 | 16.82 | 16.40 |
| 8 | 17.31 | 17.76 | 18.09 | 18.44 | 18.62 | 18.66 | 18.58 | 18.65 | 19.75 | 21.34 | 20.71 | 20.47 | 20.12 | 19.57 |
| 9 | 19.34 | 20.00 | 20.61 | 21.18 | 21.56 | 21.75 | 21.74 | 21.84 | 23.13 | 25.02 | 24.31 | 24.03 | 23.61 | 22.93 |
| 10 | 21.20 | 22.10 | 22.93 | 23.68 | 24.18 | 24.49 | 24.63 | 24.86 | 26.39 | 28.63 | 27.98 | 27.67 | 27.19 | 26.41 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 27.984 |
| SC2 | 0 | 8 | 18.648 |
| SC3 | -18 | 7 | 15.638 |
| SC4 | -25 | 6 | 12.652 |
| SC5 | -34 | 6 | 12.587 |
| A | 2015 mm |
|---|---|
| B | 900 mm |
| C | 1190 mm |
| F | 860 mm |
| E1 | 818 mm |
| E | 1635 mm |
| D IN | 1 x Ø28 |
| D OUT | 1 x Ø42 |
| Length | 2015 mm |
|---|---|
| Width | 900 mm |
| Height | 1190 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.