EA-445AG10-C01 C
34.93 kW
Defrost: None
Product code: EA-263GE10-C19 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 24,659 m³/h |
|---|---|
| Air throw | 31 m |
| External surface | 158.7 m² |
| Inner volume | 65.3 dm³ |
| Fin spacing | 10.0 mm |
| Fin material | Aluminium |
| Net weight | 270 kg |
| Quantity | 2 |
|---|---|
| Diameter | 630 mm |
| Speed | 1,330 rpm |
| Power | 2,500 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 64.0 dB(A) |
|---|---|
| Sound power | 87.3 dB(A) |
| Energy class | D |
| Inlet | Ø35 |
|---|---|
| Outlet | Ø54 |
| EA-263GE10-C19 C | None |
|---|---|
| EA-263GE10-C19 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 15.23 | 15.02 | 14.89 | 14.83 | 14.72 | 14.58 | 14.42 | 14.39 | 15.22 | 16.41 | 15.94 | 15.77 | 15.52 | 15.15 |
| 5 | 19.61 | 19.48 | 19.50 | 19.55 | 19.49 | 19.35 | 19.17 | 19.10 | 20.19 | 21.77 | 21.12 | 20.88 | 20.54 | 20.02 |
| 6 | 23.81 | 24.02 | 24.24 | 24.46 | 24.47 | 24.39 | 24.23 | 24.15 | 25.54 | 27.54 | 26.71 | 26.40 | 25.94 | 25.23 |
| 7 | 27.83 | 28.39 | 28.91 | 29.38 | 29.59 | 29.62 | 29.51 | 29.44 | 31.14 | 33.58 | 32.60 | 32.22 | 31.66 | 30.76 |
| 8 | 31.60 | 32.60 | 33.35 | 34.14 | 34.60 | 34.80 | 34.81 | 34.83 | 36.87 | 39.84 | 38.73 | 38.28 | 37.62 | 36.56 |
| 9 | 35.08 | 36.35 | 37.64 | 38.82 | 39.62 | 40.02 | 40.19 | 40.31 | 42.70 | 46.20 | 44.99 | 44.50 | 43.77 | 42.55 |
| 10 | 38.00 | 39.86 | 41.56 | 43.08 | 44.12 | 44.82 | 45.25 | 45.61 | 48.43 | 52.54 | 51.33 | 50.80 | 49.99 | 48.64 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 13.57 | 13.34 | 13.22 | 13.17 | 13.08 | 12.96 | 12.82 | 12.89 | 13.66 | 14.77 | 14.39 | 14.26 | 14.07 | 13.76 |
| 5 | 17.39 | 17.26 | 17.22 | 17.24 | 17.17 | 17.03 | 16.87 | 16.89 | 17.88 | 19.31 | 18.75 | 18.56 | 18.28 | 17.85 |
| 6 | 21.23 | 21.26 | 21.31 | 21.45 | 21.45 | 21.35 | 21.17 | 21.17 | 22.39 | 24.17 | 23.44 | 23.16 | 22.77 | 22.16 |
| 7 | 24.87 | 25.16 | 25.47 | 25.77 | 25.87 | 25.80 | 25.65 | 25.64 | 27.12 | 29.28 | 28.39 | 28.06 | 27.57 | 26.78 |
| 8 | 28.35 | 28.96 | 29.54 | 30.07 | 30.32 | 30.36 | 30.26 | 30.21 | 31.97 | 34.54 | 33.54 | 33.14 | 32.55 | 31.59 |
| 9 | 31.63 | 32.62 | 33.40 | 34.20 | 34.65 | 34.84 | 34.84 | 34.90 | 36.96 | 39.94 | 38.84 | 38.38 | 37.70 | 36.60 |
| 10 | 34.69 | 35.93 | 37.18 | 38.31 | 39.01 | 39.37 | 39.48 | 39.63 | 41.98 | 45.41 | 44.22 | 43.72 | 42.97 | 41.71 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 51.334 | 44.223 |
| SC2 | 0 | 8 | 34.827 | 30.211 |
| SC3 | -18 | 7 | 29.492 | 25.833 |
| SC4 | -25 | 6 | 24.236 | 21.313 |
| SC5 | -34 | 6 | 23.891 | 21.261 |
| A | 3015 mm |
|---|---|
| B | 1000 mm |
| C | 1190 mm |
| F | 960 mm |
| E1 | 1318 mm |
| E | 2635 mm |
| D IN | 1 x Ø35 |
| D OUT | 1 x Ø54 |
| Length | 3015 mm |
|---|---|
| Width | 1000 mm |
| Height | 1190 mm |
Our engineers answer with a selection for your conditions.