EA-140AG10-C01 C
5.44 kW
Defrost: Electric
Product code: EA-330AC10-C01 C ED
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 4,163 m³/h |
|---|---|
| Air throw | 8 m |
| External surface | 15.1 m² |
| Inner volume | 7.1 dm³ |
| Fin spacing | 10.0 mm |
| Fin material | Aluminium |
| Net weight | 47 kg |
| Quantity | 3 |
|---|---|
| Diameter | 300 mm |
| Speed | 1,380 rpm |
| Power | 186 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 48.0 dB(A) |
|---|---|
| Sound power | 69.4 dB(A) |
| Energy class | B |
| Inlet | Ø12,7 |
|---|---|
| Outlet | Ø28 |
| EA-330AC10-C01 C | None |
|---|---|
| EA-330AC10-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 2.26 | 2.21 | 2.18 | 2.16 | 2.14 | 2.11 | 2.07 | 2.09 | 2.21 | 2.37 | 2.30 | 2.28 | 2.24 | 2.19 |
| 5 | 2.96 | 2.94 | 2.93 | 2.92 | 2.90 | 2.87 | 2.83 | 2.84 | 3.00 | 3.23 | 3.13 | 3.10 | 3.05 | 2.98 |
| 6 | 3.66 | 3.67 | 3.69 | 3.71 | 3.71 | 3.69 | 3.65 | 3.65 | 3.87 | 4.17 | 4.03 | 3.98 | 3.91 | 3.80 |
| 7 | 4.35 | 4.41 | 4.46 | 4.52 | 4.55 | 4.54 | 4.51 | 4.52 | 4.78 | 5.16 | 4.99 | 4.93 | 4.83 | 4.68 |
| 8 | 5.00 | 5.11 | 5.23 | 5.33 | 5.39 | 5.41 | 5.39 | 5.41 | 5.73 | 6.19 | 6.00 | 5.92 | 5.81 | 5.62 |
| 9 | 5.59 | 5.76 | 5.94 | 6.11 | 6.22 | 6.28 | 6.29 | 6.32 | 6.69 | 7.24 | 7.03 | 6.94 | 6.81 | 6.60 |
| 10 | 6.12 | 6.36 | 6.60 | 6.81 | 6.96 | 7.04 | 7.09 | 7.17 | 7.61 | 8.26 | 8.08 | 7.98 | 7.84 | 7.60 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 8.076 |
| SC2 | 0 | 8 | 5.408 |
| SC3 | -18 | 7 | 4.534 |
| SC4 | -25 | 6 | 3.689 |
| SC5 | -34 | 6 | 3.664 |
| A | 1657 mm |
|---|---|
| B | 523 mm |
| C | 445 mm |
| F | 345 mm |
| E1 | 451 mm |
| E2 | 434 mm |
| E | 1335 mm |
| D IN | 1 x Ø12,7 |
| D OUT | 1 x Ø28 |
| Length | 1657 mm |
|---|---|
| Width | 523 mm |
| Height | 445 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.