EA-245AG8-C01 C
18.19 kW
Defrost: None
Product code: EA-345AC8-C01 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 16,284 m³/h |
|---|---|
| Air throw | 19 m |
| External surface | 44.5 m² |
| Inner volume | 17.3 dm³ |
| Fin spacing | 8.0 mm |
| Fin material | Aluminium |
| Net weight | 109 kg |
| Quantity | 3 |
|---|---|
| Diameter | 450 mm |
| Speed | 1,310 rpm |
| Power | 1,470 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 58.0 dB(A) |
|---|---|
| Sound power | 80.0 dB(A) |
| Energy class | D |
| Inlet | Ø19 |
|---|---|
| Outlet | Ø42 |
| EA-345AC8-C01 C | None |
|---|---|
| EA-345AC8-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 7.26 | 7.13 | 7.03 | 6.94 | 6.83 | 6.69 | 6.55 | 6.55 | 6.89 | 7.39 | 7.14 | 7.04 | 6.91 | 6.72 |
| 5 | 9.62 | 9.61 | 9.61 | 9.60 | 9.52 | 9.37 | 9.20 | 9.20 | 9.72 | 10.45 | 10.08 | 9.95 | 9.77 | 9.46 |
| 6 | 11.96 | 12.14 | 12.29 | 12.39 | 12.40 | 12.31 | 12.14 | 12.16 | 12.85 | 13.82 | 13.32 | 13.15 | 12.90 | 12.52 |
| 7 | 14.05 | 14.43 | 14.80 | 15.15 | 15.35 | 15.37 | 15.24 | 15.29 | 16.17 | 17.43 | 16.84 | 16.61 | 16.28 | 15.75 |
| 8 | 15.86 | 16.46 | 17.01 | 17.45 | 17.77 | 17.96 | 18.02 | 18.20 | 19.32 | 20.95 | 20.44 | 20.24 | 19.88 | 19.26 |
| 9 | 17.56 | 18.30 | 19.07 | 19.76 | 20.22 | 20.50 | 20.63 | 20.85 | 22.14 | 24.03 | 23.46 | 23.23 | 22.88 | 22.31 |
| 10 | 19.13 | 20.14 | 21.14 | 22.02 | 22.64 | 23.04 | 23.25 | 23.52 | 24.99 | 27.13 | 26.53 | 26.27 | 25.88 | 25.22 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 26.525 |
| SC2 | 0 | 8 | 18.197 |
| SC3 | -18 | 7 | 15.244 |
| SC4 | -25 | 6 | 12.291 |
| SC5 | -34 | 6 | 12.015 |
| A | 2467 mm |
|---|---|
| B | 590 mm |
| C | 645 mm |
| F | 395 mm |
| E1 | 718 mm |
| E2 | 700 mm |
| E | 2135 mm |
| D IN | 1 x Ø19 |
| D OUT | 1 x Ø42 |
| Length | 2467 mm |
|---|---|
| Width | 590 mm |
| Height | 645 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.