EA-250AG6-C10 C
27.28 kW
Defrost: None
Product code: EA-345AE6-C01 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 13,956 m³/h |
|---|---|
| Air throw | 17 m |
| External surface | 86.3 m² |
| Inner volume | 26.2 dm³ |
| Fin spacing | 6.0 mm |
| Fin material | Aluminium |
| Net weight | 131 kg |
| Quantity | 3 |
|---|---|
| Diameter | 450 mm |
| Speed | 1,310 rpm |
| Power | 1,470 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 58.0 dB(A) |
|---|---|
| Sound power | 80.0 dB(A) |
| Energy class | D |
| Inlet | Ø22 |
|---|---|
| Outlet | Ø54 |
| EA-345AE6-C01 C | None |
|---|---|
| EA-345AE6-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 11.53 | 11.43 | 11.38 | 11.35 | 11.25 | 11.10 | 10.91 | 11.12 | 11.82 | 12.78 | 12.44 | 12.31 | 12.12 | 11.84 |
| 5 | 14.88 | 14.97 | 15.08 | 15.16 | 15.11 | 14.96 | 14.73 | 14.90 | 15.80 | 17.06 | 16.52 | 16.35 | 16.11 | 15.77 |
| 6 | 18.20 | 18.55 | 18.87 | 19.14 | 19.17 | 19.08 | 18.84 | 18.97 | 20.09 | 21.67 | 20.92 | 20.64 | 20.24 | 19.64 |
| 7 | 21.16 | 21.80 | 22.41 | 22.95 | 23.27 | 23.33 | 23.13 | 23.25 | 24.60 | 26.57 | 25.64 | 25.26 | 24.72 | 23.87 |
| 8 | 23.78 | 24.73 | 25.61 | 26.28 | 26.76 | 27.00 | 27.00 | 27.27 | 28.92 | 31.34 | 30.46 | 30.07 | 29.42 | 28.35 |
| 9 | 26.22 | 27.38 | 28.58 | 29.63 | 30.27 | 30.63 | 30.72 | 31.04 | 32.91 | 35.65 | 34.69 | 34.26 | 33.62 | 32.54 |
| 10 | 28.48 | 30.03 | 31.56 | 32.89 | 33.76 | 34.27 | 34.45 | 34.84 | 36.95 | 40.02 | 38.97 | 38.48 | 37.75 | 36.50 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 38.968 |
| SC2 | 0 | 8 | 27.267 |
| SC3 | -18 | 7 | 23.102 |
| SC4 | -25 | 6 | 18.868 |
| SC5 | -34 | 6 | 18.301 |
| A | 2467 mm |
|---|---|
| B | 640 mm |
| C | 645 mm |
| F | 445 mm |
| E1 | 718 mm |
| E2 | 700 mm |
| E | 2135 mm |
| D IN | 1 x Ø22 |
| D OUT | 1 x Ø54 |
| Length | 2467 mm |
|---|---|
| Width | 640 mm |
| Height | 645 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.