EA-163FE7-C19 C
17.45 kW
Defrost: None
Product code: EA-435AG10-C01 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 8,352 m³/h |
|---|---|
| Air throw | 11 m |
| External surface | 55.9 m² |
| Inner volume | 25.7 dm³ |
| Fin spacing | 10.0 mm |
| Fin material | Aluminium |
| Net weight | 121 kg |
| Quantity | 4 |
|---|---|
| Diameter | 350 mm |
| Speed | 1,340 rpm |
| Power | 660 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 54.0 dB(A) |
|---|---|
| Sound power | 76.0 dB(A) |
| Energy class | B |
| Inlet | Ø22 |
|---|---|
| Outlet | Ø42 |
| EA-435AG10-C01 C | None |
|---|---|
| EA-435AG10-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 7.55 | 7.49 | 7.46 | 7.46 | 7.41 | 7.32 | 7.20 | 7.33 | 7.79 | 8.43 | 8.21 | 8.14 | 8.04 | 7.90 |
| 5 | 9.65 | 9.69 | 9.76 | 9.83 | 9.82 | 9.73 | 9.59 | 9.70 | 10.29 | 11.11 | 10.75 | 10.63 | 10.45 | 10.20 |
| 6 | 11.68 | 11.87 | 12.06 | 12.24 | 12.30 | 12.25 | 12.12 | 12.20 | 12.92 | 13.96 | 13.47 | 13.28 | 13.01 | 12.58 |
| 7 | 13.69 | 14.04 | 14.38 | 14.65 | 14.80 | 14.81 | 14.70 | 14.79 | 15.65 | 16.91 | 16.32 | 16.08 | 15.72 | 15.12 |
| 8 | 15.52 | 16.08 | 16.60 | 17.06 | 17.32 | 17.39 | 17.30 | 17.42 | 18.44 | 19.92 | 19.26 | 18.98 | 18.55 | 17.79 |
| 9 | 17.17 | 17.92 | 18.63 | 19.27 | 19.65 | 19.87 | 19.91 | 20.06 | 21.24 | 22.93 | 22.23 | 21.90 | 21.40 | 20.51 |
| 10 | 18.67 | 19.66 | 20.57 | 21.27 | 21.82 | 22.13 | 22.23 | 22.49 | 23.85 | 25.82 | 25.15 | 24.82 | 24.29 | 23.27 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 25.146 |
| SC2 | 0 | 8 | 17.421 |
| SC3 | -18 | 7 | 14.726 |
| SC4 | -25 | 6 | 12.063 |
| SC5 | -34 | 6 | 11.736 |
| A | 2357 mm |
|---|---|
| B | 673 mm |
| C | 525 mm |
| F | 495 mm |
| E1 | 517.5 mm |
| E2 | 500 mm |
| E | 2035 mm |
| D IN | 1 x Ø22 |
| D OUT | 1 x Ø42 |
| Length | 2357 mm |
|---|---|
| Width | 623 mm |
| Height | 525 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.