EA-263EC10-C06 C
17.35 kW
Defrost: None
Product code: EA-245AG10-C01 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 9,187 m³/h |
|---|---|
| Air throw | 16 m |
| External surface | 48.9 m² |
| Inner volume | 22.7 dm³ |
| Fin spacing | 10.0 mm |
| Fin material | Aluminium |
| Net weight | 110 kg |
| Quantity | 2 |
|---|---|
| Diameter | 450 mm |
| Speed | 1,310 rpm |
| Power | 980 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 56.0 dB(A) |
|---|---|
| Sound power | 78.0 dB(A) |
| Energy class | C |
| Inlet | Ø19 |
|---|---|
| Outlet | Ø42 |
| EA-245AG10-C01 C | None |
|---|---|
| EA-245AG10-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 7.19 | 7.19 | 7.21 | 7.23 | 7.19 | 7.10 | 6.97 | 7.10 | 7.55 | 8.15 | 7.92 | 7.85 | 7.73 | 7.53 |
| 5 | 9.17 | 9.32 | 9.47 | 9.59 | 9.61 | 9.55 | 9.42 | 9.53 | 10.11 | 10.92 | 10.55 | 10.43 | 10.26 | 10.02 |
| 6 | 11.11 | 11.44 | 11.75 | 11.97 | 12.09 | 12.10 | 11.99 | 12.10 | 12.81 | 13.84 | 13.36 | 13.18 | 12.91 | 12.49 |
| 7 | 12.87 | 13.43 | 13.93 | 14.36 | 14.60 | 14.69 | 14.61 | 14.74 | 15.61 | 16.89 | 16.32 | 16.10 | 15.76 | 15.19 |
| 8 | 14.42 | 15.18 | 15.87 | 16.48 | 16.88 | 17.04 | 17.11 | 17.33 | 18.40 | 19.94 | 19.33 | 19.06 | 18.66 | 17.98 |
| 9 | 15.83 | 16.82 | 17.72 | 18.42 | 18.95 | 19.28 | 19.42 | 19.68 | 20.90 | 22.66 | 22.10 | 21.84 | 21.44 | 20.73 |
| 10 | 17.11 | 18.35 | 19.37 | 20.35 | 21.06 | 21.50 | 21.72 | 22.04 | 23.41 | 25.39 | 24.79 | 24.50 | 24.05 | 23.22 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 24.789 |
| SC2 | 0 | 8 | 17.331 |
| SC3 | -18 | 7 | 14.475 |
| SC4 | -25 | 6 | 11.745 |
| SC5 | -34 | 6 | 11.198 |
| A | 1767 mm |
|---|---|
| B | 690 mm |
| C | 645 mm |
| F | 495 mm |
| E1 | 718 mm |
| E | 1435 mm |
| D IN | 1 x Ø19 |
| D OUT | 1 x Ø42 |
| Length | 1767 mm |
|---|---|
| Width | 690 mm |
| Height | 645 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.