EA-163FE10-C08 C
17.13 kW
Defrost: None
Product code: EA-340AE7-C01 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 8,575 m³/h |
|---|---|
| Air throw | 12 m |
| External surface | 54.8 m² |
| Inner volume | 18.1 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 95 kg |
| Quantity | 3 |
|---|---|
| Diameter | 400 mm |
| Speed | 1,430 rpm |
| Power | 480 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 63.0 dB(A) |
|---|---|
| Sound power | 85.0 dB(A) |
| Energy class | B |
| Inlet | Ø19 |
|---|---|
| Outlet | Ø42 |
| EA-340AE7-C01 C | None |
|---|---|
| EA-340AE7-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 7.29 | 7.23 | 7.20 | 7.18 | 7.11 | 7.02 | 6.89 | 7.03 | 7.47 | 8.08 | 7.87 | 7.80 | 7.69 | 7.51 |
| 5 | 9.38 | 9.44 | 9.51 | 9.56 | 9.54 | 9.44 | 9.28 | 9.39 | 9.96 | 10.75 | 10.40 | 10.28 | 10.12 | 9.90 |
| 6 | 11.46 | 11.67 | 11.87 | 12.01 | 12.06 | 12.00 | 11.84 | 11.93 | 12.62 | 13.62 | 13.13 | 12.95 | 12.68 | 12.27 |
| 7 | 13.37 | 13.78 | 14.17 | 14.49 | 14.64 | 14.63 | 14.49 | 14.57 | 15.41 | 16.65 | 16.04 | 15.81 | 15.45 | 14.88 |
| 8 | 15.03 | 15.63 | 16.18 | 16.67 | 16.97 | 17.05 | 17.05 | 17.22 | 18.25 | 19.72 | 19.05 | 18.76 | 18.34 | 17.63 |
| 9 | 16.57 | 17.39 | 18.06 | 18.71 | 19.12 | 19.34 | 19.38 | 19.58 | 20.76 | 22.48 | 21.85 | 21.57 | 21.14 | 20.42 |
| 10 | 18.00 | 18.98 | 19.93 | 20.75 | 21.31 | 21.62 | 21.72 | 21.96 | 23.29 | 25.21 | 24.53 | 24.22 | 23.73 | 22.90 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 24.532 |
| SC2 | 0 | 8 | 17.217 |
| SC3 | -18 | 7 | 14.568 |
| SC4 | -25 | 6 | 11.869 |
| SC5 | -34 | 6 | 11.520 |
| A | 2017 mm |
|---|---|
| B | 636 mm |
| C | 605 mm |
| F | 445 mm |
| E1 | 568 mm |
| E2 | 550 mm |
| E | 1685 mm |
| D IN | 1 x Ø19 |
| D OUT | 1 x Ø42 |
| Length | 2017 mm |
|---|---|
| Width | 636 mm |
| Height | 605 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.