EA-245AG7-C01 C
19.59 kW
Defrost: None
Product code: EA-440AE10-C01 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 12,165 m³/h |
|---|---|
| Air throw | 13 m |
| External surface | 53.4 m² |
| Inner volume | 23.7 dm³ |
| Fin spacing | 10.0 mm |
| Fin material | Aluminium |
| Net weight | 121 kg |
| Quantity | 4 |
|---|---|
| Diameter | 400 mm |
| Speed | 1,430 rpm |
| Power | 640 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 64.0 dB(A) |
|---|---|
| Sound power | 86.0 dB(A) |
| Energy class | B |
| Inlet | Ø19 |
|---|---|
| Outlet | Ø42 |
| EA-440AE10-C01 C | None |
|---|---|
| EA-440AE10-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 8.01 | 8.07 | 8.13 | 8.18 | 8.15 | 8.07 | 7.94 | 8.06 | 8.54 | 9.22 | 8.94 | 8.85 | 8.69 | 8.45 |
| 5 | 10.17 | 10.44 | 10.67 | 10.86 | 10.93 | 10.90 | 10.78 | 10.92 | 11.58 | 12.51 | 12.11 | 11.97 | 11.77 | 11.48 |
| 6 | 12.29 | 12.77 | 13.21 | 13.58 | 13.78 | 13.82 | 13.75 | 13.90 | 14.74 | 15.94 | 15.43 | 15.23 | 14.94 | 14.47 |
| 7 | 14.11 | 14.82 | 15.47 | 16.05 | 16.43 | 16.60 | 16.68 | 16.93 | 17.96 | 19.46 | 18.87 | 18.63 | 18.27 | 17.67 |
| 8 | 15.72 | 16.69 | 17.57 | 18.25 | 18.80 | 19.13 | 19.29 | 19.57 | 20.80 | 22.59 | 22.05 | 21.82 | 21.45 | 20.84 |
| 9 | 17.20 | 18.28 | 19.45 | 20.46 | 21.16 | 21.63 | 21.88 | 22.23 | 23.63 | 25.67 | 25.09 | 24.82 | 24.41 | 23.69 |
| 10 | 18.53 | 19.94 | 21.34 | 22.57 | 23.48 | 24.10 | 24.45 | 24.90 | 26.47 | 28.76 | 28.15 | 27.85 | 27.39 | 26.57 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 28.152 |
| SC2 | 0 | 8 | 19.573 |
| SC3 | -18 | 7 | 16.225 |
| SC4 | -25 | 6 | 13.209 |
| SC5 | -34 | 6 | 12.404 |
| A | 2567 mm |
|---|---|
| B | 636 mm |
| C | 605 mm |
| F | 445 mm |
| E1 | 568 mm |
| E2 | 550 mm |
| E | 2235 mm |
| D IN | 1 x Ø19 |
| D OUT | 1 x Ø42 |
| Length | 2567 mm |
|---|---|
| Width | 636 mm |
| Height | 605 mm |
Our engineers answer with a selection for your conditions.