EA-463FG10-C19 C
75.89 kW
Defrost: None
Product code: EA-463FC4-C13 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 69,708 m³/h |
|---|---|
| Air throw | 49 m |
| External surface | 334.1 m² |
| Inner volume | 68.6 dm³ |
| Fin spacing | 4.6 mm |
| Fin material | Aluminium |
| Net weight | 457 kg |
| Quantity | 4 |
|---|---|
| Diameter | 630 mm |
| Speed | 1,330 rpm |
| Power | 10,800 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 70.0 dB(A) |
|---|---|
| Sound power | 93.9 dB(A) |
| Energy class | E |
| Inlet | Ø42 |
|---|---|
| Outlet | Ø66,7 |
| EA-463FC4-C13 C | None |
|---|---|
| EA-463FC4-C13 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 31.91 | 31.87 | 31.85 | 31.83 | 31.59 | 31.28 | 30.93 | 30.98 | 32.73 | 35.29 | 34.31 | 33.95 | 33.45 | 32.70 |
| 5 | 41.05 | 41.81 | 42.20 | 42.65 | 42.67 | 42.42 | 41.99 | 42.04 | 44.48 | 47.93 | 46.53 | 46.03 | 45.29 | 44.14 |
| 6 | 48.96 | 50.56 | 52.02 | 53.30 | 54.06 | 54.45 | 54.18 | 54.27 | 57.43 | 61.93 | 60.06 | 59.37 | 58.38 | 56.87 |
| 7 | 55.89 | 58.42 | 60.67 | 62.61 | 63.83 | 64.51 | 64.80 | 65.33 | 69.34 | 75.15 | 73.46 | 72.80 | 71.84 | 70.30 |
| 8 | 62.30 | 65.88 | 69.06 | 71.79 | 73.59 | 74.67 | 75.21 | 75.88 | 80.56 | 87.36 | 85.40 | 84.62 | 83.47 | 81.61 |
| 9 | 68.17 | 72.89 | 77.12 | 80.77 | 83.27 | 84.84 | 85.71 | 86.59 | 91.97 | 99.80 | 97.61 | 96.72 | 95.40 | 93.21 |
| 10 | ≈ 73.51 | 79.42 | 84.81 | 89.48 | 92.78 | 94.97 | 96.24 | 97.40 | 103.50 | 112.41 | 110.04 | 109.05 | 107.55 | 105.05 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 28.31 | 28.10 | 27.94 | 27.93 | 27.77 | 27.54 | 27.27 | 27.55 | 29.14 | 31.47 | 30.69 | 30.40 | 30.00 | 29.39 |
| 5 | 36.42 | 36.72 | 36.98 | 37.20 | 37.12 | 36.84 | 36.42 | 36.68 | 38.85 | 41.95 | 40.81 | 40.41 | 39.82 | 38.99 |
| 6 | 44.26 | 45.10 | 46.00 | 46.72 | 46.95 | 46.81 | 46.41 | 46.64 | 49.40 | 53.31 | 51.74 | 51.16 | 50.36 | 49.15 |
| 7 | 50.75 | 52.51 | 54.11 | 55.53 | 56.37 | 56.80 | 56.89 | 57.28 | 60.66 | 65.51 | 63.54 | 62.79 | 61.70 | 60.00 |
| 8 | 56.80 | 59.38 | 61.70 | 63.71 | 64.97 | 65.65 | 65.89 | 66.50 | 70.58 | 76.52 | 74.69 | 73.97 | 72.91 | 71.20 |
| 9 | 62.40 | 65.92 | 69.06 | 71.76 | 73.53 | 74.55 | 75.00 | 75.71 | 80.36 | 87.17 | 85.07 | 84.23 | 82.97 | 80.91 |
| 10 | 67.56 | 72.08 | 76.14 | 79.64 | 82.01 | 83.45 | 84.16 | 85.03 | 90.27 | 97.95 | 95.64 | 94.67 | 93.23 | 90.83 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 110.036 | 95.636 |
| SC2 | 0 | 8 | 75.884 | 66.496 |
| SC3 | -18 | 7 | 63.173 | 55.921 |
| SC4 | -25 | 6 | 52.016 | 46.003 |
| SC5 | -34 | 6 | 49.366 | 44.558 |
| A | 4415 mm |
|---|---|
| B | 900 mm |
| C | 1190 mm |
| F | 860 mm |
| G | 1010 mm |
| E1 | 1018 mm |
| E2 | 1000 mm |
| E | 4035 mm |
| D IN | 1 x Ø42 |
| D OUT | 1 x Ø66,7 |
| Length | 4415 mm |
|---|---|
| Width | 1010 mm |
| Height | 1190 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.