EA-291AG4-C04 C
121.69 kW
Defrost: None
Product code: EA-463FG4-C08 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 51,459 m³/h |
|---|---|
| Air throw | 38 m |
| External surface | 668.3 m² |
| Inner volume | 135.0 dm³ |
| Fin spacing | 4.6 mm |
| Fin material | Aluminium |
| Net weight | 627 kg |
| Quantity | 4 |
|---|---|
| Diameter | 630 mm |
| Speed | 1,340 rpm |
| Power | 7,600 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 75.0 dB(A) |
|---|---|
| Sound power | 98.0 dB(A) |
| Energy class | D |
| Inlet | Ø54 |
|---|---|
| Outlet | Ø80 |
| EA-463FG4-C08 C | None |
|---|---|
| EA-463FG4-C08 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 54.56 | 54.26 | 54.38 | 54.61 | 54.50 | 54.14 | 53.54 | 54.58 | 58.06 | 62.93 | 61.54 | 61.08 | 60.45 | 59.57 |
| 5 | 68.73 | 69.40 | 70.10 | 70.76 | 70.83 | 70.37 | 69.57 | 70.46 | 74.75 | 80.89 | 78.63 | 77.83 | 76.71 | 75.04 |
| 6 | 82.31 | 84.16 | 85.50 | 86.95 | 87.50 | 87.30 | 86.45 | 87.15 | 92.33 | 99.83 | 96.60 | 95.39 | 93.63 | 90.85 |
| 7 | 94.43 | 97.54 | 100.44 | 103.02 | 104.48 | 104.67 | 103.92 | 104.53 | 110.65 | 119.62 | 115.59 | 114.00 | 111.64 | 107.79 |
| 8 | 105.40 | 109.90 | 113.98 | 117.56 | 119.73 | 120.75 | 120.62 | 121.67 | 128.96 | 139.63 | 135.24 | 133.28 | 130.36 | 125.51 |
| 9 | 115.59 | 121.64 | 127.11 | 131.83 | 134.83 | 136.28 | 136.48 | 137.64 | 145.85 | 157.81 | 153.32 | 151.31 | 148.29 | 143.16 |
| 10 | 124.97 | 132.74 | 139.75 | 145.78 | 149.67 | 151.82 | 152.38 | 153.74 | 162.90 | 176.20 | 171.25 | 168.96 | 165.49 | not rated |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | not rated | not rated | not rated | not rated | not rated | not rated | not rated | 45.87 | 48.82 | 52.98 | 51.84 | 51.47 | 50.95 | 50.22 |
| 5 | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated |
| 6 | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated |
| 7 | not rated | not rated | 83.93 | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated |
| 8 | not rated | not rated | 96.13 | 98.29 | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated |
| 9 | not rated | not rated | 107.51 | 110.59 | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated |
| 10 | not rated | 113.94 | 118.48 | 122.47 | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 171.247 | — |
| SC2 | 0 | 8 | 121.672 | — |
| SC3 | -18 | 7 | 103.741 | — |
| SC4 | -25 | 6 | 85.501 | — |
| SC5 | -34 | 6 | 82.819 | — |
| A | 4415 mm |
|---|---|
| B | 1100 mm |
| C | 1190 mm |
| F | 1060 mm |
| G | 1135 mm |
| E1 | 1018 mm |
| E2 | 1000 mm |
| E | 4035 mm |
| D IN | 1 x Ø54 |
| D OUT | 1 x Ø80 |
| Length | 4415 mm |
|---|---|
| Width | 1100 mm |
| Height | 1190 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.