EA-291AI4-C04 C
131.98 kW
Defrost: None
Product code: EA-480GG7-C01 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 71,917 m³/h |
|---|---|
| Air throw | 42 m |
| External surface | 703.0 m² |
| Inner volume | 205.0 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 925 kg |
| Quantity | 4 |
|---|---|
| Diameter | 800 mm |
| Speed | 900 rpm |
| Power | 7,200 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 6 |
| Sound pressure | 63.0 dB(A) |
|---|---|
| Sound power | 87.0 dB(A) |
| Energy class | D |
| Inlet | Ø42 |
|---|---|
| Outlet | Ø66,7 |
| EA-480GG7-C01 C | None |
|---|---|
| EA-480GG7-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 57.62 | 57.43 | 57.44 | 57.54 | 57.29 | 56.77 | 56.07 | 57.22 | 60.88 | 65.90 | 64.38 | 63.87 | 63.00 | 61.67 |
| 5 | 73.45 | 74.10 | 74.76 | 75.36 | 75.22 | 74.71 | 73.80 | 74.77 | 79.36 | 85.80 | 83.37 | 82.54 | 81.38 | 79.70 |
| 6 | 88.40 | 90.37 | 92.12 | 93.57 | 94.02 | 93.69 | 92.73 | 93.44 | 98.89 | 106.85 | 103.48 | 102.23 | 100.43 | 97.63 |
| 7 | 102.43 | 106.05 | 108.69 | 111.31 | 112.60 | 112.78 | 112.04 | 112.75 | 119.39 | 129.02 | 124.79 | 123.13 | 120.72 | 116.86 |
| 8 | 114.61 | 119.68 | 124.28 | 128.33 | 130.82 | 132.05 | 131.80 | 132.64 | 140.45 | 151.88 | 147.05 | 145.08 | 142.14 | 137.30 |
| 9 | 125.78 | 132.58 | 138.74 | 144.07 | 147.51 | 149.26 | 149.81 | 151.31 | 160.50 | 173.94 | 169.38 | 167.41 | 164.02 | 158.26 |
| 10 | 136.05 | 144.75 | 152.62 | 159.42 | 163.85 | 166.43 | 167.43 | 169.26 | 179.56 | 194.57 | 189.60 | 187.36 | 183.96 | 178.15 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 47.88 | 47.40 | 47.24 | 47.28 | 47.10 | 46.75 | 46.27 | 47.16 | 50.19 | 54.41 | 53.24 | 52.85 | 52.33 | 51.61 |
| 5 | 60.70 | 60.66 | 60.86 | 61.16 | 61.07 | 60.66 | 60.00 | 60.70 | 64.41 | 69.72 | 67.80 | 67.13 | 66.18 | 64.80 |
| 6 | 73.56 | 74.17 | 74.88 | 75.60 | 75.64 | 75.29 | 74.52 | 75.04 | 79.50 | 85.94 | 83.29 | 82.30 | 80.86 | 78.61 |
| 7 | 85.70 | 87.28 | 88.79 | 90.15 | 90.65 | 90.45 | 89.61 | 90.01 | 95.26 | 102.94 | 99.55 | 98.23 | 96.28 | 93.10 |
| 8 | 97.18 | 99.96 | 102.50 | 104.33 | 105.43 | 105.59 | 104.89 | 105.31 | 111.42 | 120.32 | 116.34 | 114.72 | 112.30 | 108.33 |
| 9 | 107.95 | 111.65 | 115.35 | 118.54 | 120.23 | 120.83 | 120.41 | 120.95 | 127.96 | 138.15 | 133.74 | 131.83 | 128.96 | 124.11 |
| 10 | 117.19 | 122.53 | 127.40 | 131.71 | 134.31 | 135.73 | 135.98 | 136.74 | 144.71 | 156.22 | 151.39 | 149.22 | 145.94 | 140.19 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 189.597 | 151.392 |
| SC2 | 0 | 8 | 132.635 | 105.311 |
| SC3 | -18 | 7 | 111.967 | 90.440 |
| SC4 | -25 | 6 | 92.122 | 74.881 |
| SC5 | -34 | 6 | 88.951 | 73.792 |
| A | 5615 mm |
|---|---|
| B | 1150 mm |
| C | 1430 mm |
| F | 1110 mm |
| G | 1215 mm |
| E1 | 1318 mm |
| E2 | 1300 mm |
| E | 5235 mm |
| D IN | 2 x Ø42 |
| D OUT | 2 x Ø66,7 |
| Length | 5615 mm |
|---|---|
| Width | 1150 mm |
| Height | 1430 mm |
Our engineers answer with a selection for your conditions.