EA-630BC7-C01 C
11.32 kW
Defrost: Electric
Product code: EA-530AE7-C05 C ED
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 4,980 m³/h |
|---|---|
| Air throw | 7 m |
| External surface | 48.5 m² |
| Inner volume | 15.4 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 66 kg |
| Quantity | 5 |
|---|---|
| Diameter | 300 mm |
| Speed | 1,300 rpm |
| Power | 600 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 47.0 dB(A) |
|---|---|
| Sound power | 69.0 dB(A) |
| Energy class | C |
| Inlet | Ø15,9 |
|---|---|
| Outlet | Ø35 |
| EA-530AE7-C05 C | None |
|---|---|
| EA-530AE7-C05 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 4.92 | 4.93 | 4.95 | 4.97 | 4.96 | 4.91 | 4.84 | 4.96 | 5.28 | 5.72 | 5.58 | 5.53 | 5.47 | 5.40 |
| 5 | 6.23 | 6.31 | 6.40 | 6.48 | 6.49 | 6.46 | 6.38 | 6.47 | 6.86 | 7.43 | 7.19 | 7.10 | 6.99 | 6.81 |
| 6 | 7.52 | 7.70 | 7.85 | 8.01 | 8.07 | 8.06 | 7.99 | 8.06 | 8.54 | 9.23 | 8.91 | 8.79 | 8.60 | 8.30 |
| 7 | 8.70 | 9.01 | 9.30 | 9.54 | 9.68 | 9.69 | 9.63 | 9.70 | 10.27 | 11.10 | 10.72 | 10.56 | 10.32 | 9.95 |
| 8 | 9.78 | 10.22 | 10.62 | 10.98 | 11.21 | 11.30 | 11.29 | 11.36 | 12.02 | 12.99 | 12.57 | 12.38 | 12.10 | 11.65 |
| 9 | 10.74 | 11.33 | 11.86 | 12.28 | 12.57 | 12.74 | 12.78 | 12.93 | 13.70 | 14.83 | 14.42 | 14.22 | 13.92 | 13.38 |
| 10 | 11.64 | 12.38 | 12.99 | 13.57 | 13.97 | 14.19 | 14.27 | 14.45 | 15.32 | 16.57 | 16.13 | 15.91 | 15.60 | 15.05 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 16.127 |
| SC2 | 0 | 8 | 11.355 |
| SC3 | -18 | 7 | 9.610 |
| SC4 | -25 | 6 | 7.849 |
| SC5 | -34 | 6 | 7.566 |
| A | 2407 mm |
|---|---|
| B | 567 mm |
| C | 445 mm |
| F | 395 mm |
| E1 | 427.5 mm |
| E2 | 410 mm |
| E | 2085 mm |
| D IN | 1 x Ø15,9 |
| D OUT | 1 x Ø35 |
| Length | 2407 mm |
|---|---|
| Width | 567 mm |
| Height | 445 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.