EA-335AG6-C01 C
14.56 kW
Defrost: Electric
Product code: EA-535AC10-C01 C ED
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 12,787 m³/h |
|---|---|
| Air throw | 14 m |
| External surface | 34.9 m² |
| Inner volume | 16.1 dm³ |
| Fin spacing | 10.0 mm |
| Fin material | Aluminium |
| Net weight | 101 kg |
| Quantity | 5 |
|---|---|
| Diameter | 350 mm |
| Speed | 1,340 rpm |
| Power | 825 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 55.0 dB(A) |
|---|---|
| Sound power | 77.0 dB(A) |
| Energy class | C |
| Inlet | Ø19 |
|---|---|
| Outlet | Ø35 |
| EA-535AC10-C01 C | None |
|---|---|
| EA-535AC10-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 5.85 | 5.80 | 5.77 | 5.74 | 5.68 | 5.60 | 5.50 | 5.52 | 5.82 | 6.25 | 6.04 | 5.96 | 5.84 | 5.67 |
| 5 | 7.61 | 7.68 | 7.74 | 7.80 | 7.79 | 7.73 | 7.63 | 7.64 | 8.09 | 8.71 | 8.42 | 8.32 | 8.18 | 7.97 |
| 6 | 9.35 | 9.56 | 9.75 | 9.90 | 9.98 | 9.98 | 9.91 | 9.94 | 10.52 | 11.35 | 10.98 | 10.85 | 10.65 | 10.34 |
| 7 | 10.92 | 11.29 | 11.65 | 11.98 | 12.20 | 12.29 | 12.27 | 12.34 | 13.07 | 14.14 | 13.71 | 13.54 | 13.30 | 12.91 |
| 8 | 12.27 | 12.82 | 13.32 | 13.79 | 14.06 | 14.27 | 14.39 | 14.56 | 15.47 | 16.80 | 16.43 | 16.28 | 16.04 | 15.59 |
| 9 | 13.53 | 14.27 | 14.87 | 15.49 | 15.92 | 16.23 | 16.40 | 16.61 | 17.66 | 19.20 | 18.80 | 18.63 | 18.38 | 17.94 |
| 10 | 14.69 | 15.56 | 16.42 | 17.20 | 17.78 | 18.17 | 18.42 | 18.68 | 19.87 | 21.60 | 21.19 | 21.00 | 20.72 | 20.21 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 21.189 |
| SC2 | 0 | 8 | 14.555 |
| SC3 | -18 | 7 | 12.081 |
| SC4 | -25 | 6 | 9.750 |
| SC5 | -34 | 6 | 9.405 |
| A | 2857 mm |
|---|---|
| B | 523 mm |
| C | 525 mm |
| F | 345 mm |
| E1 | 517.5 mm |
| E2 | 500 mm |
| E | 2535 mm |
| D IN | 1 x Ø19 |
| D OUT | 1 x Ø35 |
| Length | 2857 mm |
|---|---|
| Width | 523 mm |
| Height | 525 mm |
Our engineers answer with a selection for your conditions.