EA-463FC7-C13 C
59.16 kW
Defrost: Electric
Product code: EA-563FC10-C08 C ED
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 81,853 m³/h |
|---|---|
| Air throw | 47 m |
| External surface | 203.5 m² |
| Inner volume | 84.5 dm³ |
| Fin spacing | 10.0 mm |
| Fin material | Aluminium |
| Net weight | 518 kg |
| Quantity | 5 |
|---|---|
| Diameter | 630 mm |
| Speed | 1,340 rpm |
| Power | 9,500 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 75.0 dB(A) |
|---|---|
| Sound power | 99.0 dB(A) |
| Energy class | E |
| Inlet | Ø42 |
|---|---|
| Outlet | Ø66,7 |
| EA-563FC10-C08 C | None |
|---|---|
| EA-563FC10-C08 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 24.46 | 24.15 | 23.91 | 23.72 | 23.40 | 23.02 | 22.62 | 22.49 | 23.69 | 25.44 | 24.58 | 24.26 | 23.81 | 23.14 |
| 5 | 31.93 | 32.04 | 32.13 | 32.18 | 31.93 | 31.57 | 31.09 | 30.96 | 32.69 | 35.12 | 33.93 | 33.47 | 32.81 | 31.81 |
| 6 | 38.97 | 39.75 | 40.41 | 40.91 | 41.00 | 40.69 | 40.28 | 40.14 | 42.42 | 45.64 | 44.10 | 43.52 | 42.70 | 41.42 |
| 7 | 45.53 | 46.89 | 48.26 | 49.39 | 49.95 | 50.07 | 49.87 | 49.86 | 52.73 | 56.84 | 55.02 | 54.32 | 53.28 | 51.65 |
| 8 | 50.86 | 53.10 | 55.13 | 56.92 | 58.08 | 58.77 | 59.11 | 59.54 | 63.19 | 68.41 | 66.42 | 65.63 | 64.46 | 62.56 |
| 9 | 55.93 | 58.99 | 61.75 | 64.16 | 65.79 | 66.82 | 67.39 | 67.98 | 72.17 | 78.30 | 76.56 | 75.85 | 74.79 | 73.03 |
| 10 | 60.60 | 64.54 | 68.10 | 71.22 | 73.40 | 74.83 | 75.68 | 76.46 | 81.22 | 88.19 | 86.32 | 85.55 | 84.37 | 82.40 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 21.99 | 21.62 | 21.36 | 21.19 | 20.93 | 20.62 | 20.30 | 20.27 | 21.39 | 23.00 | 22.28 | 22.02 | 21.65 | 21.09 |
| 5 | 28.70 | 28.59 | 28.48 | 28.48 | 28.27 | 27.95 | 27.55 | 27.50 | 29.06 | 31.26 | 30.26 | 29.90 | 29.38 | 28.56 |
| 6 | 35.14 | 35.52 | 35.85 | 36.14 | 36.11 | 35.86 | 35.44 | 35.37 | 37.38 | 40.24 | 38.91 | 38.42 | 37.72 | 36.65 |
| 7 | 41.24 | 42.25 | 43.13 | 43.69 | 43.99 | 43.95 | 43.66 | 43.64 | 46.14 | 49.73 | 48.12 | 47.51 | 46.62 | 45.21 |
| 8 | 46.64 | 48.31 | 49.81 | 51.17 | 51.94 | 52.19 | 52.09 | 52.17 | 55.22 | 59.62 | 57.81 | 57.09 | 56.04 | 54.33 |
| 9 | 51.53 | 53.81 | 55.89 | 57.74 | 58.95 | 59.69 | 60.05 | 60.51 | 64.21 | 69.64 | 67.75 | 66.95 | 65.76 | 63.80 |
| 10 | 56.01 | 59.04 | 61.78 | 64.18 | 65.82 | 66.85 | 67.42 | 68.01 | 72.20 | 78.34 | 76.59 | 75.86 | 74.77 | 72.90 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 86.324 | 76.591 |
| SC2 | 0 | 8 | 59.542 | 52.173 |
| SC3 | -18 | 7 | 49.668 | 43.855 |
| SC4 | -25 | 6 | 40.406 | 35.853 |
| SC5 | -34 | 6 | 39.199 | 35.270 |
| A | 5415 mm |
|---|---|
| B | 900 mm |
| C | 1190 mm |
| F | 860 mm |
| G | 935 mm |
| E1 | 1018 mm |
| E2 | 1000 mm |
| E | 5035 mm |
| D IN | 1 x Ø42 |
| D OUT | 1 x Ø66,7 |
| Length | 5415 mm |
|---|---|
| Width | 900 mm |
| Height | 1190 mm |