EA-150BE7-C10 C
12.51 kW
Defrost: Electric
Product code: EA-630BC4-C05 C ED
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 5,864 m³/h |
|---|---|
| Air throw | 7 m |
| External surface | 55.8 m² |
| Inner volume | 11.8 dm³ |
| Fin spacing | 4.2 mm |
| Fin material | Aluminium |
| Net weight | 62 kg |
| Quantity | 6 |
|---|---|
| Diameter | 300 mm |
| Speed | 1,300 rpm |
| Power | 720 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 48.0 dB(A) |
|---|---|
| Sound power | 70.0 dB(A) |
| Energy class | D |
| Inlet | Ø22 |
|---|---|
| Outlet | Ø28 |
| EA-630BC4-C05 C | None |
|---|---|
| EA-630BC4-C05 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 5.16 | 5.34 | 5.51 | 5.64 | 5.70 | 5.70 | 5.65 | 5.81 | 6.20 | 6.73 | 6.58 | 6.53 | 6.47 | 6.39 |
| 5 | 6.41 | 6.75 | 7.05 | 7.30 | 7.44 | 7.49 | 7.44 | 7.59 | 8.07 | 8.74 | 8.50 | 8.41 | 8.28 | 8.07 |
| 6 | 7.45 | 7.93 | 8.36 | 8.68 | 8.93 | 9.07 | 9.11 | 9.29 | 9.88 | 10.74 | 10.48 | 10.37 | 10.21 | 9.95 |
| 7 | 8.38 | 8.95 | 9.53 | 10.04 | 10.40 | 10.61 | 10.71 | 10.90 | 11.59 | 12.60 | 12.28 | 12.15 | 11.96 | 11.63 |
| 8 | ≈ 9.21 | 9.95 | 10.70 | 11.36 | 11.84 | 12.14 | 12.29 | 12.52 | 13.31 | 14.47 | 14.13 | 13.98 | 13.74 | 13.34 |
| 9 | ≈ 9.89 | 10.87 | 11.79 | 12.62 | 13.23 | 13.64 | 13.86 | 14.15 | 15.04 | 16.35 | 15.99 | 15.82 | 15.55 | 15.08 |
| 10 | ≈ 10.54 | 11.70 | 12.81 | 13.83 | 14.58 | 15.11 | 15.42 | 15.77 | 16.77 | 18.24 | 17.87 | 17.68 | 17.38 | 16.84 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 17.871 |
| SC2 | 0 | 8 | 12.521 |
| SC3 | -18 | 7 | 10.203 |
| SC4 | -25 | 6 | 8.359 |
| SC5 | -34 | 6 | 7.561 |
| A | 2557 mm |
|---|---|
| B | 517 mm |
| C | 445 mm |
| F | 345 mm |
| E1 | 385 mm |
| E2 | 367 mm |
| E | 2235 mm |
| D IN | 1 x Ø22 |
| D OUT | 1 x Ø28 |
| Length | 2407 mm |
|---|---|
| Width | 517 mm |
| Height | 445 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.