EA-240AE4-C01 C
11.94 kW
Defrost: None
Product code: EA-630BC6-C01 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 7,307 m³/h |
|---|---|
| Air throw | 8 m |
| External surface | 40.2 m² |
| Inner volume | 11.7 dm³ |
| Fin spacing | 6.0 mm |
| Fin material | Aluminium |
| Net weight | 77 kg |
| Quantity | 6 |
|---|---|
| Diameter | 300 mm |
| Speed | 1,380 rpm |
| Power | 372 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 51.0 dB(A) |
|---|---|
| Sound power | 72.7 dB(A) |
| Energy class | C |
| Inlet | Ø12,7 |
|---|---|
| Outlet | Ø28 |
| EA-630BC6-C01 C | None |
|---|---|
| EA-630BC6-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 4.84 | 4.97 | 5.08 | 5.17 | 5.20 | 5.19 | 5.15 | 5.24 | 5.57 | 6.02 | 5.87 | 5.82 | 5.75 | 5.62 |
| 5 | 6.10 | 6.37 | 6.60 | 6.80 | 6.91 | 6.94 | 6.92 | 7.02 | 7.45 | 8.07 | 7.85 | 7.77 | 7.66 | 7.49 |
| 6 | 7.17 | 7.57 | 7.94 | 8.26 | 8.44 | 8.58 | 8.64 | 8.79 | 9.35 | 10.17 | 9.94 | 9.84 | 9.68 | 9.44 |
| 7 | 8.11 | 8.67 | 9.11 | 9.56 | 9.88 | 10.09 | 10.20 | 10.38 | 11.04 | 12.01 | 11.76 | 11.65 | 11.49 | 11.22 |
| 8 | 8.96 | 9.61 | 10.27 | 10.86 | 11.30 | 11.59 | 11.76 | 11.97 | 12.74 | 13.87 | 13.60 | 13.47 | 13.28 | 12.95 |
| 9 | ≈ 9.52 | 10.53 | 11.36 | 12.11 | 12.67 | 13.06 | 13.31 | 13.58 | 14.45 | 15.74 | 15.45 | 15.31 | 15.09 | 14.70 |
| 10 | ≈ 10.33 | 11.38 | 12.39 | 13.30 | 14.00 | 14.51 | 14.84 | 15.17 | 16.16 | 17.61 | 17.31 | 17.16 | 16.91 | 16.47 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 17.313 |
| SC2 | 0 | 8 | 11.974 |
| SC3 | -18 | 7 | 9.704 |
| SC4 | -25 | 6 | 7.940 |
| SC5 | -34 | 6 | 7.266 |
| A | 2557 mm |
|---|---|
| B | 523 mm |
| C | 445 mm |
| F | 345 mm |
| E1 | 385 mm |
| E2 | 367 mm |
| E | 2235 mm |
| D IN | 1 x Ø12,7 |
| D OUT | 1 x Ø28 |
| Length | 2557 mm |
|---|---|
| Width | 523 mm |
| Height | 445 mm |