EA-463GG10-C08 C
100.78 kW
Defrost: None
Product code: EA-663EE7-C11 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 89,664 m³/h |
|---|---|
| Air throw | 46 m |
| External surface | 405.6 m² |
| Inner volume | 123.5 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 651 kg |
| Quantity | 6 |
|---|---|
| Diameter | 630 mm |
| Speed | 1,330 rpm |
| Power | 15,600 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 74.0 dB(A) |
|---|---|
| Sound power | 98.0 dB(A) |
| Energy class | E |
| Inlet | Ø66,7 |
|---|---|
| Outlet | Ø66,7 |
| EA-663EE7-C11 C | None |
|---|---|
| EA-663EE7-C11 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 41.97 | 41.82 | 41.61 | 41.55 | 41.21 | 40.69 | 40.08 | 40.44 | 42.68 | 45.95 | 44.58 | 44.07 | 43.35 | 42.28 |
| 5 | 53.98 | 54.80 | 55.44 | 55.90 | 55.80 | 55.30 | 54.49 | 54.94 | 58.22 | 62.75 | 60.87 | 60.21 | 59.22 | 57.60 |
| 6 | 65.31 | 67.08 | 68.86 | 70.26 | 70.80 | 70.67 | 70.04 | 70.53 | 74.72 | 80.57 | 78.04 | 77.09 | 75.78 | 73.80 |
| 7 | 74.72 | 77.96 | 80.87 | 83.40 | 84.95 | 85.75 | 85.94 | 86.91 | 92.10 | 99.47 | 96.43 | 95.26 | 93.53 | 90.81 |
| 8 | 83.34 | 87.93 | 92.04 | 95.57 | 97.87 | 99.16 | 99.67 | 100.84 | 107.09 | 116.16 | 113.37 | 112.27 | 110.62 | 107.93 |
| 9 | 91.25 | 97.30 | 102.75 | 107.46 | 110.64 | 112.56 | 113.47 | 114.88 | 122.02 | 132.44 | 129.31 | 128.03 | 126.11 | 122.91 |
| 10 | 98.45 | 106.07 | 112.98 | 119.00 | 123.19 | 125.87 | 127.27 | 128.99 | 137.07 | 148.90 | 145.47 | 144.02 | 141.84 | 138.09 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 36.68 | 36.36 | 36.18 | 36.09 | 35.81 | 35.40 | 34.89 | 35.54 | 37.58 | 40.54 | 39.46 | 39.06 | 38.50 | 37.66 |
| 5 | 47.41 | 47.64 | 47.87 | 48.07 | 47.82 | 47.38 | 46.68 | 47.26 | 50.13 | 54.12 | 52.61 | 52.09 | 51.37 | 50.33 |
| 6 | 57.62 | 58.76 | 59.73 | 60.49 | 60.63 | 60.30 | 59.51 | 59.93 | 63.50 | 68.51 | 66.38 | 65.62 | 64.54 | 62.90 |
| 7 | 67.22 | 69.14 | 71.08 | 72.67 | 73.40 | 73.43 | 72.78 | 73.34 | 77.66 | 83.83 | 81.01 | 79.98 | 78.46 | 76.10 |
| 8 | 75.19 | 78.38 | 81.27 | 83.81 | 85.36 | 86.15 | 86.20 | 87.04 | 92.20 | 99.66 | 96.50 | 95.26 | 93.42 | 90.45 |
| 9 | 82.69 | 87.06 | 90.98 | 94.37 | 96.56 | 97.77 | 98.06 | 99.07 | 105.14 | 114.05 | 111.11 | 109.91 | 108.12 | 105.31 |
| 10 | 89.62 | 95.24 | 100.31 | 104.70 | 107.64 | 109.35 | 109.96 | 111.15 | 117.97 | 127.95 | 124.75 | 123.38 | 121.46 | 118.14 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 145.466 | 124.749 |
| SC2 | 0 | 8 | 100.841 | 87.037 |
| SC3 | -18 | 7 | 84.124 | 73.055 |
| SC4 | -25 | 6 | 68.858 | 59.726 |
| SC5 | -34 | 6 | 65.877 | 57.953 |
| A | 5215 mm |
|---|---|
| B | 1000 mm |
| C | 1190 mm |
| F | 960 mm |
| E1 | 818 mm |
| E2 | 800 mm |
| E | 4835 mm |
| D IN | 1 x Ø66,7 |
| D OUT | 1 x Ø66,7 |
| Length | 5215 mm |
|---|---|
| Width | 1000 mm |
| Height | 1190 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.