EA-HL-150AC10-A10 C
9.25 kW
Defrost: None
Product code: EA-HL-150AC7-A10 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 7,996 m³/h |
|---|---|
| Air throw | 21 m |
| External surface | 31.8 m² |
| Inner volume | 10.9 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 85 kg |
| Quantity | 1 |
|---|---|
| Diameter | 500 mm |
| Speed | 1,360 rpm |
| Power | 690 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 59.0 dB(A) |
|---|---|
| Sound power | 81.0 dB(A) |
| Energy class | D |
| Inlet | Ø12,7 |
|---|---|
| Outlet | Ø28 |
| EA-HL-150AC7-A10 C | None |
|---|---|
| EA-HL-150AC7-A10 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 4.39 | 4.46 | 4.51 | 4.55 | 4.55 | 4.52 | 4.48 | 4.47 | 4.72 | 5.08 | 4.92 | 4.86 | 4.78 | 4.65 |
| 5 | 5.61 | 5.80 | 5.97 | 6.08 | 6.15 | 6.17 | 6.15 | 6.15 | 6.51 | 7.02 | 6.81 | 6.74 | 6.62 | 6.45 |
| 6 | 6.71 | 7.03 | 7.33 | 7.59 | 7.77 | 7.89 | 7.91 | 7.92 | 8.40 | 9.09 | 8.85 | 8.76 | 8.62 | 8.39 |
| 7 | 7.63 | 8.09 | 8.52 | 8.84 | 9.11 | 9.29 | 9.41 | 9.53 | 10.13 | 11.01 | 10.80 | 10.72 | 10.58 | 10.37 |
| 8 | 8.46 | 8.99 | 9.58 | 10.08 | 10.46 | 10.72 | 10.89 | 11.05 | 11.76 | 12.80 | 12.57 | 12.47 | 12.32 | 12.07 |
| 9 | ≈ 9.21 | 9.93 | 10.64 | 11.28 | 11.77 | 12.13 | 12.37 | 12.58 | 13.40 | 14.60 | 14.36 | 14.25 | 14.09 | 13.80 |
| 10 | ≈ 9.83 | 10.76 | 11.64 | 12.44 | 13.05 | 13.51 | 13.84 | 14.11 | 15.04 | 16.40 | 16.16 | 16.05 | 15.87 | 15.55 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 3.96 | 3.98 | 4.01 | 4.04 | 4.03 | 4.00 | 3.96 | 3.97 | 4.21 | 4.54 | 4.41 | 4.36 | 4.29 | 4.18 |
| 5 | 5.04 | 5.16 | 5.28 | 5.37 | 5.41 | 5.41 | 5.38 | 5.40 | 5.71 | 6.17 | 5.99 | 5.92 | 5.83 | 5.69 |
| 6 | 6.10 | 6.34 | 6.55 | 6.74 | 6.84 | 6.88 | 6.88 | 6.92 | 7.33 | 7.92 | 7.70 | 7.62 | 7.49 | 7.29 |
| 7 | 7.01 | 7.37 | 7.69 | 7.98 | 8.18 | 8.29 | 8.37 | 8.47 | 8.99 | 9.73 | 9.49 | 9.39 | 9.24 | 9.00 |
| 8 | 7.81 | 8.30 | 8.74 | 9.08 | 9.37 | 9.56 | 9.68 | 9.81 | 10.43 | 11.34 | 11.12 | 11.03 | 10.89 | 10.64 |
| 9 | 8.55 | 9.09 | 9.67 | 10.18 | 10.56 | 10.82 | 10.99 | 11.16 | 11.87 | 12.92 | 12.68 | 12.58 | 12.42 | 12.14 |
| 10 | 9.21 | 9.91 | 10.61 | 11.24 | 11.72 | 12.07 | 12.30 | 12.51 | 13.32 | 14.50 | 14.26 | 14.14 | 13.97 | 13.66 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 16.157 | 14.258 |
| SC2 | 0 | 8 | 11.054 | 9.809 |
| SC3 | -18 | 7 | 8.959 | 8.072 |
| SC4 | -25 | 6 | 7.329 | 6.552 |
| SC5 | -34 | 6 | 6.789 | 6.155 |
| A | 1387 mm |
|---|---|
| B | 590 mm |
| C | 875 mm |
| F | 510 mm |
| E | 1035 mm |
| D IN | 1 x Ø12,7 |
| D OUT | 1 x Ø28 |
| Length | 1387 mm |
|---|---|
| Width | 590 mm |
| Height | 875 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.