EB-130BC4-B05 C
2.34 kW
Defrost: Electric
Product code: EB-225BA4-B05 C ED
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 1,816 m³/h |
|---|---|
| Air throw | 6 m |
| External surface | 8.2 m² |
| Inner volume | 1.5 dm³ |
| Fin spacing | 4.2 mm |
| Fin material | Aluminium |
| Net weight | 24 kg |
| Quantity | 2 |
|---|---|
| Diameter | 250 mm |
| Speed | 1,300 rpm |
| Power | 190 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 40.0 dB(A) |
|---|---|
| Sound power | 61.5 dB(A) |
| Energy class | E |
| Inlet | Ø9,52 |
|---|---|
| Outlet | Ø12,7 |
| EB-225BA4-B05 C | None |
|---|---|
| EB-225BA4-B05 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 0.95 | 0.97 | 0.98 | 1.00 | 1.00 | 1.00 | 1.00 | 1.01 | 1.07 | 1.15 | 1.12 | 1.11 | 1.10 | 1.08 |
| 5 | 1.20 | 1.24 | 1.28 | 1.31 | 1.33 | 1.35 | 1.35 | 1.36 | 1.44 | 1.56 | 1.52 | 1.51 | 1.49 | 1.45 |
| 6 | 1.41 | 1.47 | 1.53 | 1.59 | 1.62 | 1.65 | 1.67 | 1.69 | 1.80 | 1.95 | 1.92 | 1.91 | 1.89 | 1.85 |
| 7 | 1.61 | 1.70 | 1.79 | 1.86 | 1.91 | 1.95 | 1.98 | 2.00 | 2.13 | 2.32 | 2.28 | 2.26 | 2.24 | 2.20 |
| 8 | 1.80 | 1.92 | 2.03 | 2.13 | 2.20 | 2.25 | 2.29 | 2.32 | 2.47 | 2.68 | 2.64 | 2.62 | 2.60 | 2.55 |
| 9 | 1.96 | 2.11 | 2.26 | 2.38 | 2.48 | 2.54 | 2.59 | 2.63 | 2.80 | 3.06 | 3.01 | 2.99 | 2.96 | 2.91 |
| 10 | ≈ 2.11 | 2.30 | 2.48 | 2.62 | 2.74 | 2.83 | 2.90 | 2.95 | 3.15 | 3.43 | 3.39 | 3.37 | 3.34 | 3.28 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 3.388 |
| SC2 | 0 | 8 | 2.319 |
| SC3 | -18 | 7 | 1.884 |
| SC4 | -25 | 6 | 1.530 |
| SC5 | -34 | 6 | 1.421 |
| A | 1357 mm |
|---|---|
| B | 520 mm |
| C | 363 mm |
| F | 345 mm |
| E1 | 518 mm |
| E | 1035 mm |
| D IN | 1 x Ø9,52 |
| D OUT | 1 x Ø12,7 |
| Length | 1357 mm |
|---|---|
| Width | 520 mm |
| Height | 363 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.