EB-430BC4-B01 C
9.85 kW
Defrost: None
Product code: EB-240AC6-B01 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 6,916 m³/h |
|---|---|
| Air throw | 14 m |
| External surface | 27.7 m² |
| Inner volume | 6.9 dm³ |
| Fin spacing | 6.0 mm |
| Fin material | Aluminium |
| Net weight | 62 kg |
| Quantity | 2 |
|---|---|
| Diameter | 400 mm |
| Speed | 1,430 rpm |
| Power | 320 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 61.0 dB(A) |
|---|---|
| Sound power | 83.0 dB(A) |
| Energy class | C |
| Inlet | Ø15,9 |
|---|---|
| Outlet | Ø28 |
| EB-240AC6-B01 C | None |
|---|---|
| EB-240AC6-B01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 4.10 | 4.15 | 4.19 | 4.23 | 4.24 | 4.21 | 4.17 | 4.20 | 4.45 | 4.80 | 4.67 | 4.62 | 4.55 | 4.43 |
| 5 | 5.20 | 5.36 | 5.51 | 5.63 | 5.69 | 5.70 | 5.68 | 5.72 | 6.06 | 6.55 | 6.36 | 6.29 | 6.19 | 6.05 |
| 6 | 6.15 | 6.41 | 6.65 | 6.87 | 7.02 | 7.10 | 7.15 | 7.23 | 7.69 | 8.35 | 8.17 | 8.10 | 7.97 | 7.77 |
| 7 | 7.08 | 7.44 | 7.78 | 8.06 | 8.27 | 8.41 | 8.48 | 8.59 | 9.13 | 9.92 | 9.71 | 9.63 | 9.50 | 9.29 |
| 8 | 7.89 | 8.39 | 8.85 | 9.25 | 9.54 | 9.73 | 9.83 | 9.96 | 10.59 | 11.52 | 11.29 | 11.17 | 11.02 | 10.77 |
| 9 | 8.63 | 9.27 | 9.86 | 10.39 | 10.77 | 11.03 | 11.15 | 11.32 | 12.05 | 13.11 | 12.85 | 12.74 | 12.58 | 12.29 |
| 10 | 9.31 | 10.10 | 10.84 | 11.49 | 11.90 | 12.25 | 12.48 | 12.70 | 13.52 | 14.72 | 14.46 | 14.34 | 14.16 | 13.83 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 14.463 |
| SC2 | 0 | 8 | 9.964 |
| SC3 | -18 | 7 | 8.152 |
| SC4 | -25 | 6 | 6.652 |
| SC5 | -34 | 6 | 6.215 |
| A | 1667 mm |
|---|---|
| B | 650 mm |
| C | 617 mm |
| F | 445 mm |
| E1 | 668 mm |
| E | 1335 mm |
| D IN | 1 x Ø15,9 |
| D OUT | 1 x Ø28 |
| Length | 1667 mm |
|---|---|
| Width | 650 mm |
| Height | 617 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.