ED-230AE4-C25 C
5.77 kW
Defrost: None
Product code: ED-230AC4-C21 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 2,639 m³/h |
|---|---|
| Air throw | 5 m |
| External surface | 25.4 m² |
| Inner volume | 5.6 dm³ |
| Fin spacing | 4.2 mm |
| Fin material | Aluminium |
| Net weight | 55 kg |
| Quantity | 2 |
|---|---|
| Diameter | 300 mm |
| Speed | 1,380 rpm |
| Power | 124 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 45.0 dB(A) |
|---|---|
| Sound power | 67.1 dB(A) |
| Energy class | B |
| Inlet | Ø12,7 |
|---|---|
| Outlet | Ø28 |
| ED-230AC4-C21 C | None |
|---|---|
| ED-230AC4-C21 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 2.56 | 2.52 | 2.50 | 2.50 | 2.49 | 2.47 | 2.45 | 2.49 | 2.64 | 2.87 | 2.81 | 2.79 | 2.76 | 2.72 |
| 5 | 3.30 | 3.27 | 3.27 | 3.28 | 3.26 | 3.24 | 3.21 | 3.24 | 3.43 | 3.72 | 3.62 | 3.58 | 3.54 | 3.47 |
| 6 | 4.03 | 4.04 | 4.06 | 4.09 | 4.09 | 4.07 | 4.03 | 4.05 | 4.29 | 4.63 | 4.49 | 4.44 | 4.37 | 4.26 |
| 7 | 4.76 | 4.82 | 4.88 | 4.93 | 4.95 | 4.93 | 4.89 | 4.90 | 5.19 | 5.61 | 5.42 | 5.36 | 5.25 | 5.09 |
| 8 | 5.44 | 5.55 | 5.67 | 5.78 | 5.82 | 5.82 | 5.78 | 5.80 | 6.13 | 6.62 | 6.41 | 6.32 | 6.20 | 6.00 |
| 9 | 6.04 | 6.21 | 6.38 | 6.54 | 6.63 | 6.68 | 6.67 | 6.71 | 7.10 | 7.66 | 7.42 | 7.32 | 7.18 | 6.93 |
| 10 | 6.60 | 6.85 | 7.08 | 7.26 | 7.39 | 7.46 | 7.48 | 7.53 | 7.98 | 8.64 | 8.42 | 8.32 | 8.17 | 7.89 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 8.418 |
| SC2 | 0 | 8 | 5.797 |
| SC3 | -18 | 7 | 4.939 |
| SC4 | -25 | 6 | 4.062 |
| SC5 | -34 | 6 | 4.035 |
| A | 1348 mm |
|---|---|
| B | 1030 mm |
| C | 245 mm |
| F | 985 mm |
| G | 305 mm |
| E1 | 1035 mm |
| E2 | 518 mm |
| D IN | 1 x Ø12,7 |
| D OUT | 1 x Ø28 |
| Length | 1348 mm |
|---|---|
| Width | 1030 mm |
| Height | 305 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.