ED-530AC7-C25 C
10.58 kW
Defrost: Electric
Product code: ED-430AC4-C25 C ED
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 4,677 m³/h |
|---|---|
| Air throw | 7 m |
| External surface | 50.4 m² |
| Inner volume | 9.9 dm³ |
| Fin spacing | 4.2 mm |
| Fin material | Aluminium |
| Net weight | 89 kg |
| Quantity | 4 |
|---|---|
| Diameter | 300 mm |
| Speed | 1,300 rpm |
| Power | 480 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 46.0 dB(A) |
|---|---|
| Sound power | 68.0 dB(A) |
| Energy class | D |
| Inlet | Ø15,9 |
|---|---|
| Outlet | Ø28 |
| ED-430AC4-C25 C | None |
|---|---|
| ED-430AC4-C25 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 4.70 | 4.68 | 4.68 | 4.69 | 4.67 | 4.64 | 4.59 | 4.66 | 4.96 | 5.37 | 5.25 | 5.21 | 5.15 | 5.08 |
| 5 | 5.99 | 6.03 | 6.08 | 6.14 | 6.14 | 6.11 | 6.04 | 6.10 | 6.47 | 7.00 | 6.79 | 6.72 | 6.62 | 6.47 |
| 6 | 7.27 | 7.40 | 7.53 | 7.64 | 7.67 | 7.66 | 7.59 | 7.63 | 8.08 | 8.74 | 8.45 | 8.35 | 8.19 | 7.94 |
| 7 | 8.42 | 8.66 | 8.89 | 9.10 | 9.23 | 9.26 | 9.20 | 9.24 | 9.78 | 10.57 | 10.22 | 10.09 | 9.87 | 9.54 |
| 8 | 9.44 | 9.80 | 10.14 | 10.40 | 10.58 | 10.67 | 10.68 | 10.78 | 11.43 | 12.38 | 12.04 | 11.87 | 11.62 | 11.19 |
| 9 | 10.40 | 10.90 | 11.30 | 11.69 | 11.94 | 12.08 | 12.12 | 12.23 | 12.96 | 14.03 | 13.66 | 13.50 | 13.25 | 12.79 |
| 10 | 11.30 | 11.88 | 12.46 | 12.96 | 13.29 | 13.48 | 13.55 | 13.69 | 14.51 | 15.71 | 15.30 | 15.12 | 14.82 | 14.30 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 15.304 |
| SC2 | 0 | 8 | 10.777 |
| SC3 | -18 | 7 | 9.165 |
| SC4 | -25 | 6 | 7.526 |
| SC5 | -34 | 6 | 7.303 |
| A | 2348 mm |
|---|---|
| B | 1030 mm |
| C | 245 mm |
| F | 985 mm |
| G | 305 mm |
| E1 | 2035 mm |
| E2 | 518 mm |
| E3 | 500 mm |
| D IN | 1 x Ø15,9 |
| D OUT | 1 x Ø28 |
| Length | 2348 mm |
|---|---|
| Width | 1030 mm |
| Height | 305 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.